Fault (device stops or needs intervention)
The message reports a condition on which the device stops or needs someone to intervene. Vendor words that read as this class: Chint Protection and Fault, Yaskawa Solectria Critical, SMA events that interrupt feed-in.
Reading rule: classify by what the row says the device does, not by the vendor's word. The vendor's word is kept as written in the code's vendor_severity; this concept only says the message is a fault rather than a warning or a status.
Referenced by
Every fault code that carries this concept, by make: the cross-vendor answer to which codes trip, derate or clear by themselves.
ABB / FIMER
| Code | Family | Shown as | Claim |
|---|---|---|---|
| ABB / FIMER PVS-166-175-TL E001 | FIMER PVS-166/175-TL-US | Input OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E010 | FIMER PVS-166/175-TL-US | Bulk UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E011 | FIMER PVS-166/175-TL-US | Ramp Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E012 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E014 | FIMER PVS-166/175-TL-US | Over temp. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E015 | FIMER PVS-166/175-TL-US | Cap. Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E016 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E017 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E018 | FIMER PVS-166/175-TL-US | Leak fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E019 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E002 | FIMER PVS-166/175-TL-US | Input OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E020 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E021 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E022 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E023 | FIMER PVS-166/175-TL-US | DC injection | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E024 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E025 | FIMER PVS-166/175-TL-US | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E026 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E027 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E028 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E029 | FIMER PVS-166/175-TL-US | Mid Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E003 | FIMER PVS-166/175-TL-US | No pars (DSP) | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E030 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E031 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E032 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E033 | FIMER PVS-166/175-TL-US | Undertemper. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E034 | FIMER PVS-166/175-TL-US | IGBT not ready | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E035 | FIMER PVS-166/175-TL-US | Remote Off | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E036 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E037 | FIMER PVS-166/175-TL-US | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E004 | FIMER PVS-166/175-TL-US | Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E046 | FIMER PVS-166/175-TL-US | Str. test failed | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E049 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E005 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E050 | FIMER PVS-166/175-TL-US | AFDD Activated | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E051 | FIMER PVS-166/175-TL-US | Safety mem. Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E053 | FIMER PVS-166/175-TL-US | AFDD Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E054 | FIMER PVS-166/175-TL-US | AFDD comm. Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E055 | FIMER PVS-166/175-TL-US | AFDD wrong conf. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E057 | FIMER PVS-166/175-TL-US | Vbulk reading | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E058 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E006 | FIMER PVS-166/175-TL-US | Output OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E007 | FIMER PVS-166/175-TL-US | IGBT Sat | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E074 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E077 | FIMER PVS-166/175-TL-US | Internal Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E078 | FIMER PVS-166/175-TL-US | Riso Test fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E079 | FIMER PVS-166/175-TL-US | Wrong Sequence | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E084 | FIMER PVS-166/175-TL-US | BackFeed OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL E009 | FIMER PVS-166/175-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E001 | FIMER PVS-60-TL-US | Input OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E010 | FIMER PVS-60-TL-US | Bulk Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E103 | FIMER PVS-60-TL-US | RSD self-test fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E011 | FIMER PVS-60-TL-US | Ramp Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E012 | FIMER PVS-60-TL-US | DcDc Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E013 | FIMER PVS-60-TL-US | Wrong Mode | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E014 | FIMER PVS-60-TL-US | Over Temp. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E015 | FIMER PVS-60-TL-US | Bulk Cap Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E016 | FIMER PVS-60-TL-US | Inverter Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E017 | FIMER PVS-60-TL-US | Start Timeout | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E018 | FIMER PVS-60-TL-US | Ground Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E019 | FIMER PVS-60-TL-US | Ileak sense.fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E002 | FIMER PVS-60-TL-US | Input OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E020 | FIMER PVS-60-TL-US | Self Test Error 1 | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E021 | FIMER PVS-60-TL-US | Self Test Error 2 | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E022 | FIMER PVS-60-TL-US | Self Test Error 4 | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E023 | FIMER PVS-60-TL-US | DC in error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E024 | FIMER PVS-60-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E025 | FIMER PVS-60-TL-US | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E026 | FIMER PVS-60-TL-US | Vref Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E027 | FIMER PVS-60-TL-US | Error Meas V | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E028 | FIMER PVS-60-TL-US | Error Meas F | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E029 | FIMER PVS-60-TL-US | Mid Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E003 | FIMER PVS-60-TL-US | No Parameters | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E030 | FIMER PVS-60-TL-US | Error Meas Ileak | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E031 | FIMER PVS-60-TL-US | Error Read V | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E032 | FIMER PVS-60-TL-US | Error Read I | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E033 | FIMER PVS-60-TL-US | UTH | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E034 | FIMER PVS-60-TL-US | Interlock fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E035 | FIMER PVS-60-TL-US | Remote Off | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E036 | FIMER PVS-60-TL-US | Vout Avg error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E037 | FIMER PVS-60-TL-US | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E004 | FIMER PVS-60-TL-US | Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E046 | FIMER PVS-60-TL-US | String self test fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E049 | FIMER PVS-60-TL-US | AC FF Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E005 | FIMER PVS-60-TL-US | Comm.Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E050 | FIMER PVS-60-TL-US | AFDD Activated | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E051 | FIMER PVS-60-TL-US | Safety mem. Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E053 | FIMER PVS-60-TL-US | AFDD Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E054 | FIMER PVS-60-TL-US | AFDD comm. Fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E055 | FIMER PVS-60-TL-US | AFDD wrong conf. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E056 | FIMER PVS-60-TL-US | Over Temp. (from external box) | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E057 | FIMER PVS-60-TL-US | Vbulk reading error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E058 | FIMER PVS-60-TL-US | Pin vs Pout check error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E006 | FIMER PVS-60-TL-US | Output OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E007 | FIMER PVS-60-TL-US | IGBT Sat | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E074 | FIMER PVS-60-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E077 | FIMER PVS-60-TL-US | Internal Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E078 | FIMER PVS-60-TL-US | Riso Test fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E079 | FIMER PVS-60-TL-US | Wrong Sequence | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E081 | FIMER PVS-60-TL-US | Internal Error | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E084 | FIMER PVS-60-TL-US | BackFeed OC | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL E009 | FIMER PVS-60-TL-US | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E001 | TRIO-20.0/27.6-TL-OUTD(-US) | Input OC | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E010 | TRIO-20.0/27.6-TL-OUTD(-US) | Bulk Low | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E011 | TRIO-20.0/27.6-TL-OUTD(-US) | Ramp Fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E012 | TRIO-20.0/27.6-TL-OUTD(-US) | DcDc Fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E013 | TRIO-20.0/27.6-TL-OUTD(-US) | Wrong Mode | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E014 | TRIO-20.0/27.6-TL-OUTD(-US) | Over Temp. | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E015 | TRIO-20.0/27.6-TL-OUTD(-US) | Bulk Cap Fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E016 | TRIO-20.0/27.6-TL-OUTD(-US) | Inverter Fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E017 | TRIO-20.0/27.6-TL-OUTD(-US) | Start Timeout | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E018 | TRIO-20.0/27.6-TL-OUTD(-US) | Ground Fault | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E019 | TRIO-20.0/27.6-TL-OUTD(-US) | Ileak sense.fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E002 | TRIO-20.0/27.6-TL-OUTD(-US) | Input OV | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E020 | TRIO-20.0/27.6-TL-OUTD(-US) | Self Test Error 1 | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E021 | TRIO-20.0/27.6-TL-OUTD(-US) | Self Test Error 2 | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E022 | TRIO-20.0/27.6-TL-OUTD(-US) | Self Test Error 4 | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E023 | TRIO-20.0/27.6-TL-OUTD(-US) | DC in error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E024 | TRIO-20.0/27.6-TL-OUTD(-US) | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E025 | TRIO-20.0/27.6-TL-OUTD(-US) | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E026 | TRIO-20.0/27.6-TL-OUTD(-US) | Vref Error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E027 | TRIO-20.0/27.6-TL-OUTD(-US) | Error Meas V | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E028 | TRIO-20.0/27.6-TL-OUTD(-US) | Error Meas F | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E029 | TRIO-20.0/27.6-TL-OUTD(-US) | Mid Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E003 | TRIO-20.0/27.6-TL-OUTD(-US) | No Parameters | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E030 | TRIO-20.0/27.6-TL-OUTD(-US) | Error Meas Ileak | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E031 | TRIO-20.0/27.6-TL-OUTD(-US) | Error Read V | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E032 | TRIO-20.0/27.6-TL-OUTD(-US) | Error Read I | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E033 | TRIO-20.0/27.6-TL-OUTD(-US) | UTH | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E034 | TRIO-20.0/27.6-TL-OUTD(-US) | Interlock fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E035 | TRIO-20.0/27.6-TL-OUTD(-US) | Remote Off | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E036 | TRIO-20.0/27.6-TL-OUTD(-US) | Vout Avg error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E037 | TRIO-20.0/27.6-TL-OUTD(-US) | Riso Low | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E004 | TRIO-20.0/27.6-TL-OUTD(-US) | Bulk OV | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E046 | TRIO-20.0/27.6-TL-OUTD(-US) | String self test fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E049 | TRIO-20.0/27.6-TL-OUTD(-US) | AC FF Error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E005 | TRIO-20.0/27.6-TL-OUTD(-US) | Comm.Error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E056 | TRIO-20.0/27.6-TL-OUTD(-US) | Over Temp. external box) | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E057 | TRIO-20.0/27.6-TL-OUTD(-US) | Vbulk reading error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E058 | TRIO-20.0/27.6-TL-OUTD(-US) | Pin vs Pout check error | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E006 | TRIO-20.0/27.6-TL-OUTD(-US) | Output OC | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E007 | TRIO-20.0/27.6-TL-OUTD(-US) | IGBT Sat | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL E009 | TRIO-20.0/27.6-TL-OUTD(-US) | Internal error | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E001 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Input OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E010 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Bulk Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E011 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Ramp Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E012 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | DcDc Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E013 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Wrong Mode | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E014 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Over Temp. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E015 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Bulk Cap Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E016 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Inverter Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E017 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Start Timeout | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E018 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Ground Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E019 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Ileak sense.fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E002 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Input OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E020 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Self Test Error 1 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E021 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Self Test Error 2 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E022 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Self Test Error 4 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E023 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | DC in error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E024 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Internal error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E025 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Riso Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E026 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Vref Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E027 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Error Meas V | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E028 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Error Meas F | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E029 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Mid Bulk OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E003 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | No Parameters | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E030 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Error Meas Ileak | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E031 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Error Read V | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E032 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Error Read I | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E033 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | UTH | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E034 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Interlock fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E035 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Remote Off | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E036 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Vout Avg error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E004 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Bulk OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E046 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | String self test fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E049 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AC FF Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E005 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Comm.Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E050 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AFDD Activated | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E053 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AFDD Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E054 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AFDD comm. Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E055 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AFDD wrong conf. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E056 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Over Temp. (from external box) | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E057 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Vbulk reading error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E058 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Pin vs Pout check error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E006 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Output OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E007 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | IGBT Sat | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E077 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Internal Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E078 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Riso Test fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E079 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Wrong Sequence | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E081 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Internal Error | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E084 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | BackFeed OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E089 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Wrong Wiring | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS E009 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Internal error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E001 | UNO-DM-6.0-TL-PLUS-US | Input OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E010 | UNO-DM-6.0-TL-PLUS-US | Bulk Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E011 | UNO-DM-6.0-TL-PLUS-US | Ramp Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E012 | UNO-DM-6.0-TL-PLUS-US | DcDc Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E013 | UNO-DM-6.0-TL-PLUS-US | Wrong Mode | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E014 | UNO-DM-6.0-TL-PLUS-US | Over Temp. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E015 | UNO-DM-6.0-TL-PLUS-US | Bulk Cap Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E016 | UNO-DM-6.0-TL-PLUS-US | Inverter Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E017 | UNO-DM-6.0-TL-PLUS-US | Start Timeout | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E018 | UNO-DM-6.0-TL-PLUS-US | Ground Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E019 | UNO-DM-6.0-TL-PLUS-US | Ileak sense.fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E002 | UNO-DM-6.0-TL-PLUS-US | Input OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E020 | UNO-DM-6.0-TL-PLUS-US | Self Test Error 1 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E021 | UNO-DM-6.0-TL-PLUS-US | Self Test Error 2 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E022 | UNO-DM-6.0-TL-PLUS-US | Self Test Error 4 | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E023 | UNO-DM-6.0-TL-PLUS-US | DC in error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E024 | UNO-DM-6.0-TL-PLUS-US | Internal error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E025 | UNO-DM-6.0-TL-PLUS-US | Riso Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E026 | UNO-DM-6.0-TL-PLUS-US | Vref Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E027 | UNO-DM-6.0-TL-PLUS-US | Error Meas V | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E028 | UNO-DM-6.0-TL-PLUS-US | Error Meas F | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E029 | UNO-DM-6.0-TL-PLUS-US | Mid Bulk OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E003 | UNO-DM-6.0-TL-PLUS-US | No Parameters | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E030 | UNO-DM-6.0-TL-PLUS-US | Error Meas Ileak | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E031 | UNO-DM-6.0-TL-PLUS-US | Error Read V | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E032 | UNO-DM-6.0-TL-PLUS-US | Error Read I | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E033 | UNO-DM-6.0-TL-PLUS-US | UTH | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E034 | UNO-DM-6.0-TL-PLUS-US | Interlock fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E035 | UNO-DM-6.0-TL-PLUS-US | Remote Off | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E036 | UNO-DM-6.0-TL-PLUS-US | Vout Avg error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E004 | UNO-DM-6.0-TL-PLUS-US | Bulk OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E046 | UNO-DM-6.0-TL-PLUS-US | String self test fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E049 | UNO-DM-6.0-TL-PLUS-US | AC FF Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E005 | UNO-DM-6.0-TL-PLUS-US | Comm.Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E050 | UNO-DM-6.0-TL-PLUS-US | AFDD Activated | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E053 | UNO-DM-6.0-TL-PLUS-US | AFDD Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E054 | UNO-DM-6.0-TL-PLUS-US | AFDD comm. Fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E055 | UNO-DM-6.0-TL-PLUS-US | AFDD wrong conf. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E056 | UNO-DM-6.0-TL-PLUS-US | Over Temp. (from external box) | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E057 | UNO-DM-6.0-TL-PLUS-US | Vbulk reading error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E058 | UNO-DM-6.0-TL-PLUS-US | Pin vs Pout check error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E006 | UNO-DM-6.0-TL-PLUS-US | Output OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E007 | UNO-DM-6.0-TL-PLUS-US | IGBT Sat | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E077 | UNO-DM-6.0-TL-PLUS-US | Internal Error | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E078 | UNO-DM-6.0-TL-PLUS-US | Riso Test fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E079 | UNO-DM-6.0-TL-PLUS-US | Wrong Sequence | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E081 | UNO-DM-6.0-TL-PLUS-US | Internal Error | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E084 | UNO-DM-6.0-TL-PLUS-US | BackFeed OC | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E089 | UNO-DM-6.0-TL-PLUS-US | Wrong Wiring | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS E009 | UNO-DM-6.0-TL-PLUS-US | Internal error | has_event_class c3 drafted · lead |
CPS
| Code | Family | Shown as | Claim |
|---|---|---|---|
| CPS SCA25KTL-208 Arcboard Err | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 ARC Protect | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 Fault0100 | CPS SCA25KTL-DO/US-208 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0110 | CPS SCA25KTL-DO/US-208 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0130 | CPS SCA25KTL-DO/US-208 | Bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0150 | CPS SCA25KTL-DO/US-208 | Open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0020 | CPS SCA25KTL-DO/US-208 | Bus over volt Hardware | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0060 | CPS SCA25KTL-DO/US-208 | CPLD Fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0080 | CPS SCA25KTL-DO/US-208 | Bus Hardware over current fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Fault0090 | CPS SCA25KTL-DO/US-208 | Dynamic leakage current high | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 GFCIErr | CPS SCA25KTL-DO/US-208 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 GridF.OutLim | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 GridV.OutLim | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 IsolationErr | CPS SCA25KTL-DO/US-208 | Insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0100 | CPS SCA25KTL-DO/US-208 | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0110 | CPS SCA25KTL-DO/US-208 | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0150 | CPS SCA25KTL-DO/US-208 | Mini MCU Fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0170 | CPS SCA25KTL-DO/US-208 | DCI high | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0180 | CPS SCA25KTL-DO/US-208 | The sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0020 | CPS SCA25KTL-DO/US-208 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0230 | CPS SCA25KTL-DO/US-208 | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0030 | CPS SCA25KTL-DO/US-208 | Inverter Over Current | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0070 | CPS SCA25KTL-DO/US-208 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Protect0090 | CPS SCA25KTL-DO/US-208 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 PV2VoltOver | CPS SCA25KTL-DO/US-208 | PVx Over Volt x=1,2,3 | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 PVx Over current | CPS SCA25KTL-DO/US-208 | PVx Over current x=1,2,3 | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 PVxReverse | CPS SCA25KTL-DO/US-208 | PVx input reverse connection x=1,2,3 | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 TempOver | CPS SCA25KTL-DO/US-208 | Over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0100 | CPS SCA25KTL-DO-R/US-480 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0110 | CPS SCA25KTL-DO-R/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0130 | CPS SCA25KTL-DO-R/US-480 | Bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0150 | CPS SCA25KTL-DO-R/US-480 | Open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0020 | CPS SCA25KTL-DO-R/US-480 | Bus over volt Hardware | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0060 | CPS SCA25KTL-DO-R/US-480 | CPLD Fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Fault0090 | CPS SCA25KTL-DO-R/US-480 | Static leakage current high | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0100 | CPS SCA25KTL-DO-R/US-480 | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0110 | CPS SCA25KTL-DO-R/US-480 | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0150 | CPS SCA25KTL-DO-R/US-480 | Mini MCU Fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0170 | CPS SCA25KTL-DO-R/US-480 | DCI high | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0180 | CPS SCA25KTL-DO-R/US-480 | The sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0020 | CPS SCA25KTL-DO-R/US-480 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0230 | CPS SCA25KTL-DO-R/US-480 | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0030 | CPS SCA25KTL-DO-R/US-480 | Inverter Over Current | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0070 | CPS SCA25KTL-DO-R/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Protect0090 | CPS SCA25KTL-DO-R/US-480 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCA36KTL Arcboard Err | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL ARC Protect | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL Fault0100 | CPS SCA36KTL-DO/US-480 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0110 | CPS SCA36KTL-DO/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0130 | CPS SCA36KTL-DO/US-480 | Bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0150 | CPS SCA36KTL-DO/US-480 | Open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0020 | CPS SCA36KTL-DO/US-480 | Bus over volt Hardware | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0060 | CPS SCA36KTL-DO/US-480 | CPLD Fault | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0080 | CPS SCA36KTL-DO/US-480 | Bus Hardware overcurrent fault | has_event_class c2 drafted · lead |
| CPS SCA36KTL Fault0090 | CPS SCA36KTL-DO/US-480 | Dynamic leakage current high | has_event_class c2 drafted · lead |
| CPS SCA36KTL GFCIErr | CPS SCA36KTL-DO/US-480 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCA36KTL GridF.OutLim | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL GridV.OutLim | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL IsolationErr | CPS SCA36KTL-DO/US-480 | Insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0100 | CPS SCA36KTL-DO/US-480 | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0110 | CPS SCA36KTL-DO/US-480 | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0150 | CPS SCA36KTL-DO/US-480 | Mini MCU Fault | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0170 | CPS SCA36KTL-DO/US-480 | DCI high | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0180 | CPS SCA36KTL-DO/US-480 | The sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0020 | CPS SCA36KTL-DO/US-480 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0230 | CPS SCA36KTL-DO/US-480 | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0030 | CPS SCA36KTL-DO/US-480 | Inverter Over Current | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0070 | CPS SCA36KTL-DO/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA36KTL Protect0090 | CPS SCA36KTL-DO/US-480 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCA36KTL PVxReverse | CPS SCA36KTL-DO/US-480 | PVx input reverse connection x=1,2,3 | has_event_class c6 verified · fact |
| CPS SCA36KTL TempOver | CPS SCA36KTL-DO/US-480 | Over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault0000-0150 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV1…PV16 SwitchConnec tError | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault1000-1070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV1…PV16 SwitchConnec tError | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault2000-2150 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV1 …PV16 ReverseInject Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault3000-3070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV1 …PV16 ReverseInject Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault4000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PN Bus DropFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault4010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus High VoltageDiffere ntialFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault4030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Boost OverCurrentF ault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault4040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV OverVoltageF ault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV High Current Low Voltage Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Junction Box Temperature Sensor Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC Bulkhead Connector Temperature Sensor Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DC Bulkhead Connector Temperature Sensor Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Power Board Temperature Sensor Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5050 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Core Board Temperature Sensor Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5060 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC Bulkhead Connector Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DC Bulkhead Connector Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5080 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC Bulkhead Connector Warning | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5090 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DC Pair Plug Terminal Warning | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault5100 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bulkhead Connector and Junction Box Abnormal | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Junction Box OverTempera tureFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC Bulkhead Connector OverTempera tureFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DC Bulkhead Connector OverTempera tureFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Power Board OverTempera tureFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Core Board OverTempera tureFault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6050 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | CT Board Abnormal Communicatio n Alarm | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6080 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | IVScanFaultB USLow | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault6100 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | TripToDSPCo mmunicateWa rn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault7000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Over Voltage Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault7010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PID voltage stability alarm | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault7020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | SVG voltage stability alarm | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault7030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | N-line abnormal alarm | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Fault7040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PIDOverhigh voltage Warn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T PFault0000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Sum High Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T PFault0010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Power Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T PFault0110 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | BUS HW Overvolt Fault | has_event_class c3 drafted · lead |
| CPS SCA50-100K-T PFault0130 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Internal hardware failure | has_event_class c3 verified · fact |
| CPS SCA50-100K-T PFault0140 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Open Loop SelfChk Fault | has_event_class c3 drafted · lead |
| CPS SCA50-100K-T PFault0020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Different High Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T PFault0030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Relay Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T PFault0040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Steady State GFCI Fault | has_event_class c2 verified · fact |
| CPS SCA50-100K-T PFault0050 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bst hardware overcurrent fault | has_event_class c2 verified · fact |
| CPS SCA50-100K-T PFault0070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | CPLD Clock Fault | has_event_class c3 drafted · lead |
| CPS SCA50-100K-T PFault0080 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv HW Overcurr Fault | has_event_class c3 verified · fact |
| CPS SCA50-100K-T Protect0000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Sum High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Power Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0100 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Freq High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect1050 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Core Hardware Ver Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect1060 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | BUS Current High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect1070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | SPI Comm Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0110 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Freq Low | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect1110 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC Capacitor Current High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0120 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Phase Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0130 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Relay Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0140 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Over Temp Prot | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0150 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Curr Offset Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0160 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Line Volt Offset Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0170 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DCI Curr Offset Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0180 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DCI High Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0190 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | ISO Low | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Volt Diff High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0200 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | GFCI High | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0210 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Freq selective Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0230 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MiniMcu Prot | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0240 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv HW Overcurr | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0250 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Volt Unbalance Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0270 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Curr Unbalance Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus Soft start time out | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0300 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bus HW Overvolt | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0310 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | GFCI SENSOR Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0330 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Internal hardware exception | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0350 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT2 RevConnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0360 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT2 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0370 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT2 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0380 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | PV abnormal connection failure | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0390 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Open Loop SelfChk Prot | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inverter Soft start time out | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0410 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT1RevCo nnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0420 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT1 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0430 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT3RevCo nnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0440 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT3 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0480 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | TZ Shutdown Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0060 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT1 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0630 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | ARC Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0650 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Steady State GFCI Prot | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0660 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Arc Board Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0680 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT3 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0690 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Capture phase locked loop check exception | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0070 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Line Vrms OutLim | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0710 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Bst Hardware overcurrent | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0720 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Product model exception | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0730 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | CPLD program version exception | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0740 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | CPLD Clock Err | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0770 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | ARCComAbn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0790 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Zero-to-ground voltage anomaly protection | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0080 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Grid Phase Vrms OutLim | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0800 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT4 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0810 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT4RevCo nnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0820 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT4 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0830 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT5 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0840 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT5RevCo nnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0850 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT5 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0860 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT6 VoltHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0870 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT6RevCo nnect | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0880 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | MPPT6 CurrHigh | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Protect0090 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Inv Curr High | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Arcboard Err | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL ARC Protect | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL Fault0100 | CPS SCA50/60KTL-DO/US-480 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0110 | CPS SCA50/60KTL-DO/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0130 | CPS SCA50/60KTL-DO/US-480 | Bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0150 | CPS SCA50/60KTL-DO/US-480 | Open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0020 | CPS SCA50/60KTL-DO/US-480 | Bus over volt Hardware | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0060 | CPS SCA50/60KTL-DO/US-480 | CPLD Fault | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0080 | CPS SCA50/60KTL-DO/US-480 | Bus Hardware overcurrent fault | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Fault0090 | CPS SCA50/60KTL-DO/US-480 | Dynamic leakage current high | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL GFCIErr | CPS SCA50/60KTL-DO/US-480 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL GridF.OutLim | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL GridV.OutLim | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL IsolationErr | CPS SCA50/60KTL-DO/US-480 | Insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0100 | CPS SCA50/60KTL-DO/US-480 | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0110 | CPS SCA50/60KTL-DO/US-480 | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0150 | CPS SCA50/60KTL-DO/US-480 | Mini MCU Fault | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0170 | CPS SCA50/60KTL-DO/US-480 | DCI high | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0180 | CPS SCA50/60KTL-DO/US-480 | The sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0020 | CPS SCA50/60KTL-DO/US-480 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0230 | CPS SCA50/60KTL-DO/US-480 | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0030 | CPS SCA50/60KTL-DO/US-480 | Inverter Over Current | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0070 | CPS SCA50/60KTL-DO/US-480 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Protect0090 | CPS SCA50/60KTL-DO/US-480 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL PVxReverse | CPS SCA50/60KTL-DO/US-480 | PVx input reverse connection x=1,2,3 | has_event_class c6 drafted · lead |
| CPS SCA50-60KTL TempOver | CPS SCA50/60KTL-DO/US-480 | Over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0100 | CPS SCH100/125KTL-DO/US-600 | grid relay fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0110 | CPS SCH100/125KTL-DO/US-600 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0130 | CPS SCH100/125KTL-DO/US-600 | bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0150 | CPS SCH100/125KTL-DO/US-600 | open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0020 | CPS SCH100/125KTL-DO/US-600 | bus over volt hardware | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0060 | CPS SCH100/125KTL-DO/US-600 | CPLD fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0080 | CPS SCH100/125KTL-DO/US-600 | bus hardware over current fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Fault0090 | CPS SCH100/125KTL-DO/US-600 | dynamic leakage current high | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL GFCIErr | CPS SCH100/125KTL-DO/US-600 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL GridF.OutLim | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL GridV.OutLim | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL IsolationErr | CPS SCH100/125KTL-DO/US-600 | insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0100 | CPS SCH100/125KTL-DO/US-600 | sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0110 | CPS SCH100/125KTL-DO/US-600 | bus over voltage (FW) | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0150 | CPS SCH100/125KTL-DO/US-600 | mini MCU fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0170 | CPS SCH100/125KTL-DO/US-600 | DCI high | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0180 | CPS SCH100/125KTL-DO/US-600 | sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0020 | CPS SCH100/125KTL-DO/US-600 | grid relay error | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0230 | CPS SCH100/125KTL-DO/US-600 | inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0030 | CPS SCH100/125KTL-DO/US-600 | inverter over current | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0070 | CPS SCH100/125KTL-DO/US-600 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Protect0090 | CPS SCH100/125KTL-DO/US-600 | bus over voltage | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL PV Over current | CPS SCH100/125KTL-DO/US-600 | PV over current | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL PV Reverse | CPS SCH100/125KTL-DO/US-600 | PV input reverse connection | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL PVVoltOver | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL TempOver | CPS SCH100/125KTL-DO/US-600 | over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0100 | CPS SCH125KTL-AIO/US-600 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0110 | CPS SCH125KTL-AIO/US-600 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0130 | CPS SCH125KTL-AIO/US-600 | Bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0150 | CPS SCH125KTL-AIO/US-600 | Open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0020 | CPS SCH125KTL-AIO/US-600 | Bus over volt Hardware | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0060 | CPS SCH125KTL-AIO/US-600 | CPLD Fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0080 | CPS SCH125KTL-AIO/US-600 | Bus Hardware over current fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Fault0090 | CPS SCH125KTL-AIO/US-600 | Dynamic leakage current high | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO GFCIErr | CPS SCH125KTL-AIO/US-600 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO GridF.OutLim | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO GridV.OutLim | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO IsolationErr | CPS SCH125KTL-AIO/US-600 | Insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0100 | CPS SCH125KTL-AIO/US-600 | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0110 | CPS SCH125KTL-AIO/US-600 | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0150 | CPS SCH125KTL-AIO/US-600 | Mini MCU Fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0170 | CPS SCH125KTL-AIO/US-600 | DCI high | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0180 | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO Protect0020 | CPS SCH125KTL-AIO/US-600 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0230 | CPS SCH125KTL-AIO/US-600 | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0030 | CPS SCH125KTL-AIO/US-600 | Inverter Over Current | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0070 | CPS SCH125KTL-AIO/US-600 | Bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Protect0090 | CPS SCH125KTL-AIO/US-600 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO PV Over current | CPS SCH125KTL-AIO/US-600 | PV Over current | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO PV Reverse | CPS SCH125KTL-AIO/US-600 | PV input reverse connection | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO PVVoltOver | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO TempOver | CPS SCH125KTL-AIO/US-600 | Over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0130 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Grid relay fault | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0030 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Bus over voltage hardware | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0300 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Bus hardware overcurrent fault | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0390 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Open loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0650 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Static leakage current high | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Fault0740 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | CPLD fault | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0000 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Bus over voltage | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0130 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Grid relay error | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0170 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | DCI sampling offset | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0180 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | DCI high | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0230 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Mini MCU fault | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0240 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Inverter over current | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0300 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Bus over voltage firmware | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0390 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | Leakage current sensor fault | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Protect0630 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | ARC Fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0100 | CPS SCH275KTL-DO/US-800 | grid relay fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0110 | CPS SCH275KTL-DO/US-800 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0130 | CPS SCH275KTL-DO/US-800 | bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0150 | CPS SCH275KTL-DO/US-800 | open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0020 | CPS SCH275KTL-DO/US-800 | bus over volt hardware | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0060 | CPS SCH275KTL-DO/US-800 | CPLD fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Fault0090 | CPS SCH275KTL-DO/US-800 | high static leakage current | has_event_class c2 drafted · lead |
| CPS SCH275KTL GFCIErr | CPS SCH275KTL-DO/US-800 | leakage current high | has_event_class c2 drafted · lead |
| CPS SCH275KTL GridF.OutLim | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL GridV.OutLim | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL IsolationErr | CPS SCH275KTL-DO/US-800 | insulation resistance low | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0100 | CPS SCH275KTL-DO/US-800 | sensor fault of leakage current | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0110 | CPS SCH275KTL-DO/US-800 | bus over voltage (FW) | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0150 | CPS SCH275KTL-DO/US-800 | mini MCU fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0170 | CPS SCH275KTL-DO/US-800 | DCI high | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0180 | CPS SCH275KTL-DO/US-800 | sampling offset of DCI | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0020 | CPS SCH275KTL-DO/US-800 | grid relay error | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0230 | CPS SCH275KTL-DO/US-800 | inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0030 | CPS SCH275KTL-DO/US-800 | inverter over current | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0070 | CPS SCH275KTL-DO/US-800 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH275KTL Protect0090 | CPS SCH275KTL-DO/US-800 | bus over voltage | has_event_class c2 drafted · lead |
| CPS SCH275KTL PVVoltOver | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL TempOver | CPS SCH275KTL-DO/US-800 | over-temperature protection | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0100 | CPS SCH350KTL-DO/US-800 | grid relay fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0110 | CPS SCH350KTL-DO/US-800 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0130 | CPS SCH350KTL-DO/US-800 | bus over total voltage | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0150 | CPS SCH350KTL-DO/US-800 | open-loop self-check failure | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0020 | CPS SCH350KTL-DO/US-800 | bus over voltage hardware | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0060 | CPS SCH350KTL-DO/US-800 | CPLD fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Fault0090 | CPS SCH350KTL-DO/US-800 | high static leakage current | has_event_class c2 drafted · lead |
| CPS SCH350KTL High CFx voltage | CPS SCH350KTL-DO/US-800 | x=1, 2…30 | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0100 | CPS SCH350KTL-DO/US-800 | leakage current sensor fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0110 | CPS SCH350KTL-DO/US-800 | bus over voltage (firmware) | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0150 | CPS SCH350KTL-DO/US-800 | mini MCU fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0170 | CPS SCH350KTL-DO/US-800 | high DCI | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0180 | CPS SCH350KTL-DO/US-800 | DCI sampling offset | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0020 | CPS SCH350KTL-DO/US-800 | grid relay error | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0230 | CPS SCH350KTL-DO/US-800 | inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0030 | CPS SCH350KTL-DO/US-800 | inverter over current | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0070 | CPS SCH350KTL-DO/US-800 | bus imbalance | has_event_class c2 drafted · lead |
| CPS SCH350KTL Protect0090 | CPS SCH350KTL-DO/US-800 | bus over voltage | has_event_class c2 drafted · lead |
Canadian Solar
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Canadian Solar 125K-T600GL02 GRID-INTF | CSI-125K-T600GL02-U | Grid unstable | has_event_class c6 verified · fact |
| Canadian Solar 125K-T600GL02 IN I-PRO | CSI-125K-T600GL02-U | Initialization Protect ion | has_event_class c6 drafted · lead |
| Canadian Solar 125KTL-GS-E GRID-INTF | CSI-125KTL-GS-E | Grid unstable | has_event_class c6 drafted · lead |
| Canadian Solar 125KTL-GS-E IN I-PRO | CSI-125KTL-GS-E | Initialization Protect ion | has_event_class c6 drafted · lead |
| Canadian Solar 185-255K 12Power-FAULT | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | 12V power supply fault | has_event_class c5 verified · fact |
| Canadian Solar 185-255K DCinj-FAULT | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | High DC injection current | has_event_class c5 drafted · lead |
| Canadian Solar 185-255K DC-INTF | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | DC input overcurrent | has_event_class c8 verified · fact |
| Canadian Solar 185-255K DSP-B-FAULT | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Comm. failure between main and slave DSP | has_event_class c6 drafted · lead |
| Canadian Solar 185-255K GRID-INTF01/02 | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Grid interference | has_event_class c6 verified · fact |
| Canadian Solar 185-255K IG-AD | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Grid current sampling fail | has_event_class c6 drafted · lead |
| Canadian Solar 185-255K IGBT-OV-I | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Over IGBT current | has_event_class c7 drafted · lead |
| Canadian Solar 185-255K IGFOL-F | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Grid current tracking fail | has_event_class c5 drafted · lead |
| Canadian Solar 185-255K ILeak-PRO 01/02/03/04 | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Leakage current protection | has_event_class c8 drafted · lead |
| Canadian Solar 185-255K INI-FAULT | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Initialization system fault | has_event_class c6 drafted · lead |
| Canadian Solar 185-255K OV-DCA-I | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | DC input overcurrent | has_event_class c8 verified · fact |
| Canadian Solar 185-255K OV-G-I | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Over grid current | has_event_class c6 drafted · lead |
| Canadian Solar 185-255K RelayChk-FAIL | CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U | Relay check fail | has_event_class c6 drafted · lead |
| Canadian Solar 23-28KTL-CT Arcboard Err | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT ARC Protect | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT GFCIErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT GridF.OutLim | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT GridV.OutLim | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT IntFault0010-0150 | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT IntProtect0010-0620 | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT IsolationErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT PV1 (2) Reverse | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT PVVoltOver | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT TempOver | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 25-40K-T480GL01 ARC-FAULT | CSI-25/30/36/40K-T480GL01-UB | has_event_class c10 drafted · lead | |
| Canadian Solar 25-40K-T480GL01 GRID-INTF | CSI-25/30/36/40K-T480GL01-UB | Grid unstable | has_event_class c6 drafted · lead |
| Canadian Solar 25-40K-T480GL01 INI-FAULT | CSI-25/30/36/40K-T480GL01-UB | Initialization Protect ion | has_event_class c6 drafted · lead |
| Canadian Solar 25-40KTL-GS-FL ARC-FAULT | CSI-25/30/36/40KTL-GS-FL | has_event_class c10 drafted · lead | |
| Canadian Solar 25-40KTL-GS-FL GRID-INTF | CSI-25/30/36/40KTL-GS-FL | Grid unstable | has_event_class c6 drafted · lead |
| Canadian Solar 25-40KTL-GS-FL IN I-PRO | CSI-25/30/36/40KTL-GS-FL | Initialization Protection | has_event_class c6 drafted · lead |
| Canadian Solar 50-66K-T480GL01 ARC-FAULT | CSI-50/60/66K-T480GL01-UB | has_event_class c10 drafted · lead | |
| Canadian Solar 50-66K-T480GL01 GRID-INTF | CSI-50/60/66K-T480GL01-UB | Grid unstable | has_event_class c6 drafted · lead |
| Canadian Solar 50-66K-T480GL01 INI-FAULT | CSI-50/60/66K-T480GL01-UB | Initialization Protect ion | has_event_class c6 drafted · lead |
| Canadian Solar 50-66KTL-GS-FL ARC-FAULT | CSI-50/60/66KTL-GS-FL | has_event_class c10 drafted · lead | |
| Canadian Solar 50-66KTL-GS-FL GRID-INTF | CSI-50/60/66KTL-GS-FL | Grid unstable | has_event_class c6 drafted · lead |
| Canadian Solar 50-66KTL-GS-FL IN I-PRO | CSI-50/60/66KTL-GS-FL | Initialization Protection | has_event_class c6 drafted · lead |
| Canadian Solar 75-100K-T480GL02 ARC-FAULT | CSI-75/80/90/100K-T480GL02-U | has_event_class c10 drafted · lead | |
| Canadian Solar 75-100K-T480GL02 GRID-INTF | CSI-75/80/90/100K-T480GL02-U | Grid unstable | has_event_class c6 verified · fact |
| Canadian Solar 75-100K-T480GL02 INI-FAULT | CSI-75/80/90/100K-T480GL02-U | Initialization Protect ion | has_event_class c6 verified · fact |
Enphase
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Enphase IQ7 DC Resistance Low - Power Off | Enphase IQ7 Series Microinverters (IQ7, IQ7+, IQ7X, IQ7A) | has_event_class c8 verified · fact | |
| Enphase IQ8 DC Resistance Low - Power Off | Enphase IQ8 Series Microinverters | has_event_class c7 verified · fact | |
| Enphase IQ9N DC Resistance Low - Power Off | Enphase IQ9N Microinverters (IQ9N-A, IQ9N-HPB) | has_event_class c8 verified · fact | |
| Enphase M215-M250 DC Resistance Low - Power Off | Enphase M215 / M250 Microinverters | has_event_class c8 verified · fact | |
| Enphase M215-M250 GFI Tripped | Enphase M215 / M250 Microinverters | has_event_class c4 verified · fact |
Fronius
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Fronius Galvo 102 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | AC voltage too high | has_event_class c3 drafted · lead |
| Fronius Galvo 241 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Arc detected | has_event_class c5 drafted · lead |
| Fronius Galvo 242 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Arc detected | has_event_class c3 drafted · lead |
| Fronius Galvo 245 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Arc detector self test failed | has_event_class c6 drafted · lead |
| Fronius Galvo 247 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Arc detector current sensor defective | has_event_class c6 drafted · lead |
| Fronius Galvo 301 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Over-current (AC) | has_event_class c5 drafted · lead |
| Fronius Galvo 303 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Power stage set over temperature | has_event_class c5 drafted · lead |
| Fronius Galvo 308 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Intermediate circuit overvoltage | has_event_class c3 drafted · lead |
| Fronius Galvo 309 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | DC input voltage too high | has_event_class c3 drafted · lead |
| Fronius Galvo 401 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | No internal communication with power stage set. | has_event_class c3 drafted · lead |
| Fronius Galvo 406 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Power stage set temperature sensor defective | has_event_class c4 drafted · lead |
| Fronius Galvo 415 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c3 drafted · lead | |
| Fronius Galvo 416 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c3 drafted · lead | |
| Fronius Galvo 445 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Limit value setting not permitted | has_event_class c5 drafted · lead |
| Fronius Galvo 448 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Neutral conductor not connected | has_event_class c3 drafted · lead |
| Fronius Galvo 452 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Communication problem between processors | has_event_class c3 drafted · lead |
| Fronius Galvo 453 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Brief grid voltage error | has_event_class c3 drafted · lead |
| Fronius Galvo 457 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Grid relay stuck | has_event_class c8 drafted · lead |
| Fronius Galvo 472 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Fuse for solar module ground is defective | has_event_class c5 drafted · lead |
| Fronius Galvo 475 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c5 drafted · lead | |
| Fronius Galvo 482 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Commissioning is not complete | has_event_class c3 drafted · lead |
| Fronius Galvo 757 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Hardware error in the Real Time Clock module | has_event_class c4 drafted · lead |
| Fronius Galvo 766 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c3 drafted · lead | |
| Fronius Primo 102 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | AC voltage too high | has_event_class c3 drafted · lead |
| Fronius Primo 301 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Overcurrent (AC) | has_event_class c5 drafted · lead |
| Fronius Primo 303 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Overtemperature power module | has_event_class c5 drafted · lead |
| Fronius Primo 401 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | No internal communication with power stage set | has_event_class c3 drafted · lead |
| Fronius Primo 406 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Defective temperature sensor of power stage set | has_event_class c4 verified · fact |
| Fronius Primo 415 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Safety cut-out triggered by option card or RECERBO | has_event_class c3 drafted · lead |
| Fronius Primo 416 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | No communication between power module and control unit | has_event_class c3 drafted · lead |
| Fronius Primo 417 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | ID problem with hardware | has_event_class c3 drafted · lead |
| Fronius Primo 431 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Software problem | has_event_class c3 drafted · lead |
| Fronius Primo 436 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c4 drafted · lead | |
| Fronius Primo 437 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Power module problem | has_event_class c3 drafted · lead |
| Fronius Primo 438 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c4 drafted · lead | |
| Fronius Primo 443 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Intermediate circuit voltage too low or unsymmetrical | has_event_class c4 drafted · lead |
| Fronius Primo 445 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Limit value settings not permissible | has_event_class c5 drafted · lead |
| Fronius Primo 447 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Insulation fault | has_event_class c4 drafted · lead |
| Fronius Primo 448 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Neutral conductor not connected | has_event_class c3 drafted · lead |
| Fronius Primo 450 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | No guard found | has_event_class c2 drafted · lead |
| Fronius Primo 451 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Memory error detected | has_event_class c4 drafted · lead |
| Fronius Primo 452 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Communication error between processors | has_event_class c3 drafted · lead |
| Fronius Primo 453 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Short-term mains voltage error | has_event_class c3 drafted · lead |
| Fronius Primo 457 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Grid relay stuck | has_event_class c8 drafted · lead |
| Fronius Primo 474 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | RCMU sensor faulty | has_event_class c4 drafted · lead |
| Fronius Primo 475 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c5 drafted · lead | |
| Fronius Primo 476 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Supply voltage for driver too low | has_event_class c3 drafted · lead |
| Fronius Primo 479 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Intermediate circuit voltage relay switched off | has_event_class c3 drafted · lead |
| Fronius Primo 480 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c3 drafted · lead | |
| Fronius Primo 481 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c3 drafted · lead | |
| Fronius Primo 482 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Commissioning not complete | has_event_class c3 drafted · lead |
| Fronius Primo 483 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c3 drafted · lead | |
| Fronius Primo 485 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | CAN transmission buffer is full | has_event_class c3 drafted · lead |
| Fronius Primo 489 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c3 drafted · lead | |
| Fronius Primo 757 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Hardware error in the Real Time Clock module | has_event_class c4 drafted · lead |
| Fronius Primo 766 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c3 drafted · lead | |
| Fronius Symo 102 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | AC voltage too high | has_event_class c3 verified · fact |
| Fronius Symo 241 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Arc detected | has_event_class c5 drafted · lead |
| Fronius Symo 242 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Arc detected | has_event_class c3 verified · fact |
| Fronius Symo 245 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Arc Detector self-test failed | has_event_class c6 drafted · lead |
| Fronius Symo 247 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Arc Detector current sensor faulty | has_event_class c6 drafted · lead |
| Fronius Symo 301 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Overcurrent (AC) | has_event_class c5 drafted · lead |
| Fronius Symo 303 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Overtemperature DC module | has_event_class c5 drafted · lead |
| Fronius Symo 305 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | No feed-in despite closed relay | has_event_class c3 drafted · lead |
| Fronius Symo 308 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Intermediate circuit voltage too high | has_event_class c3 drafted · lead |
| Fronius Symo 309 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | DC input voltage MPPT1 too high | has_event_class c3 drafted · lead |
| Fronius Symo 311 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | DC strings polarity reversed | has_event_class c3 drafted · lead |
| Fronius Symo 313 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | DC input voltage MPPT2 too high | has_event_class c3 drafted · lead |
| Fronius Symo 314 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Timeout current sensor calibration | has_event_class c4 drafted · lead |
| Fronius Symo 315 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | AC current sensor fault | has_event_class c4 drafted · lead |
| Fronius Symo 325 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Overtemperature in connection area | has_event_class c3 drafted · lead |
| Fronius Symo 326 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Fan 1 error | has_event_class c5 drafted · lead |
| Fronius Symo 327 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Fan 2 error | has_event_class c5 drafted · lead |
| Fronius Symo 401 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Communication with power module is not possible | has_event_class c3 drafted · lead |
| Fronius Symo 406 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | AC module temperature sensor faulty (L1) | has_event_class c4 drafted · lead |
| Fronius Symo 415 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Safety cut-out triggered by option card or RECERBO | has_event_class c3 drafted · lead |
| Fronius Symo 416 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | No communication between power module and control unit | has_event_class c3 drafted · lead |
| Fronius Symo 417 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | ID problem with hardware | has_event_class c3 drafted · lead |
| Fronius Symo 431 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Software problem | has_event_class c3 drafted · lead |
| Fronius Symo 436 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c4 drafted · lead | |
| Fronius Symo 437 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Power module problem | has_event_class c3 drafted · lead |
| Fronius Symo 438 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c4 drafted · lead | |
| Fronius Symo 443 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Intermediate circuit voltage too low or unsymmetrical | has_event_class c4 drafted · lead |
| Fronius Symo 445 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c5 drafted · lead | |
| Fronius Symo 447 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Insulation fault | has_event_class c4 drafted · lead |
| Fronius Symo 448 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Neutral conductor not connected | has_event_class c3 drafted · lead |
| Fronius Symo 450 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | No guard found | has_event_class c2 drafted · lead |
| Fronius Symo 451 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Memory error detected | has_event_class c4 drafted · lead |
| Fronius Symo 452 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Communication error between processors | has_event_class c3 drafted · lead |
| Fronius Symo 453 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Grid voltage and power module do not match | has_event_class c3 drafted · lead |
| Fronius Symo 457 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Grid voltage relay error | has_event_class c8 drafted · lead |
| Fronius Symo 458 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Error during measuring signal detection | has_event_class c3 drafted · lead |
| Fronius Symo 474 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | RCMU sensor faulty | has_event_class c4 drafted · lead |
| Fronius Symo 475 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Insulation error (connection between solar module and grounding) | has_event_class c5 drafted · lead |
| Fronius Symo 476 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Supply voltage for driver too low | has_event_class c3 drafted · lead |
| Fronius Symo 479 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Intermediate circuit voltage relay switched off | has_event_class c3 drafted · lead |
| Fronius Symo 480 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead | |
| Fronius Symo 481 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead | |
| Fronius Symo 482 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Setup interrupted after initial commissioning | has_event_class c3 drafted · lead |
| Fronius Symo 483 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead | |
| Fronius Symo 485 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | CAN transmission buffer is full | has_event_class c3 drafted · lead |
| Fronius Symo 489 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead | |
| Fronius Symo 601 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | CAN bus is full | has_event_class c3 drafted · lead |
| Fronius Symo 603 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | AC module temperature sensor faulty (L3) | has_event_class c4 drafted · lead |
| Fronius Symo 607 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | RCMU fault | has_event_class c3 drafted · lead |
| Fronius Symo 608 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead | |
| Fronius Symo 757 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Hardware error in the Real Time Clock module | has_event_class c4 drafted · lead |
| Fronius Symo 760 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Internal hardware error | has_event_class c3 drafted · lead |
| Fronius Symo 766 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c3 drafted · lead |
Huawei
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Huawei SUN2000-100KTL-USH0 2001 | Huawei SUN2000-100KTL-USH0 | High string input voltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2002 | Huawei SUN2000-100KTL-USH0 | DC Arc Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2011 | Huawei SUN2000-100KTL-USH0 | String Reverse Connection | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2021 | Huawei SUN2000-100KTL-USH0 | AFCI Self-Check Failure | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2031 | Huawei SUN2000-100KTL-USH0 | Phase Wire Short-Circuited to PE | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2032 | Huawei SUN2000-100KTL-USH0 | Grid Loss | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2033 | Huawei SUN2000-100KTL-USH0 | Grid Undervoltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2034 | Huawei SUN2000-100KTL-USH0 | Grid Overvoltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2035 | Huawei SUN2000-100KTL-USH0 | Grid Voltage Imbalance | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2036 | Huawei SUN2000-100KTL-USH0 | Grid Overfrequency | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2037 | Huawei SUN2000-100KTL-USH0 | Grid Underfrequency | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2038 | Huawei SUN2000-100KTL-USH0 | Unstable Grid Frequency | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2039 | Huawei SUN2000-100KTL-USH0 | Output Overcurrent | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2040 | Huawei SUN2000-100KTL-USH0 | Output DC Component Overhigh | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2051 | Huawei SUN2000-100KTL-USH0 | Abnormal Residual Current | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2061 | Huawei SUN2000-100KTL-USH0 | Abnormal Grounding | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2062 | Huawei SUN2000-100KTL-USH0 | Low Insulation Resistance | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2063 | Huawei SUN2000-100KTL-USH0 | has_event_class c2 drafted · lead | |
| Huawei SUN2000-100KTL-USH0 2064 | Huawei SUN2000-100KTL-USH0 | Device Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 103 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | DC Over Voltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 120-125 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | String 1-6 Reverse | has_event_class c2 verified · fact |
| Huawei SUN2000-25-30KTL-US 200 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | DC Bus Voltage Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 202 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Invert Module Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 301 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Grid Voltage Abnormal | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 305 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Frequency Abnormal | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 313 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Low Array Insulation Resistance | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 318 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Residual Current Abnormal | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 321 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Cabinet Over-Tem p | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 322 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Abnormal SPI Communi cation | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 326 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Electrical Grounding Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 400 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | System Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 410 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Abnormal Auxiliary Power | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 411 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | AFCI Self-Chec k Failure | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 412 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | DC Arc Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 505 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Firmware Upgrade Failed | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 103 | Huawei SUN2000-45KTL-US-HV-D0 | High DC Input Voltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 120-127 | Huawei SUN2000-45KTL-US-HV-D0 | String 1-8 Reversed | has_event_class c6 verified · fact |
| Huawei SUN2000-45KTL-US-HV-D0 200 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal DC Circuit | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 202 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Invert Circuit | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 301 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Grid Voltage | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 305 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Grid Frequency | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 313 | Huawei SUN2000-45KTL-US-HV-D0 | Low Insulation Resistance | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 318 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Residual Current | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 321 | Huawei SUN2000-45KTL-US-HV-D0 | Cabinet Overtempe rature | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 322 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal SPI Communic ation | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 326 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Grounding | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 400 | Huawei SUN2000-45KTL-US-HV-D0 | System Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 410 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal Auxiliary Power | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 411 | Huawei SUN2000-45KTL-US-HV-D0 | AFCI Self-Chec k Failure | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 412 | Huawei SUN2000-45KTL-US-HV-D0 | DC Arc Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 413 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal PV String Connectio n | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 505 | Huawei SUN2000-45KTL-US-HV-D0 | Upgrade Failed | has_event_class c2 drafted · lead |
KACO new energy
| Code | Family | Shown as | Claim |
|---|---|---|---|
| KACO new energy blueplanet TL3 100 | KACO blueplanet 87.0-165 TL3 | Protection shutdown HW overtemperature | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 101 | KACO blueplanet 87.0-165 TL3 | Temperature plausibility er-ror | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 102 | KACO blueplanet 87.0-165 TL3 | Plausibility fault efficiency | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 105 | KACO blueplanet 87.0-165 TL3 | Relay plausibility error | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 108 | KACO blueplanet 87.0-165 TL3 | Grid failure overvoltage L1 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 111 | KACO blueplanet 87.0-165 TL3 | Grid failure undervoltage L1 | has_event_class c7 verified · fact |
| KACO new energy blueplanet TL3 112 | KACO blueplanet 87.0-165 TL3 | Grid failure undervoltage L2 | has_event_class c7 drafted · lead |
| KACO new energy blueplanet TL3 113 | KACO blueplanet 87.0-165 TL3 | Grid failure undervoltage L3 | has_event_class c7 drafted · lead |
| KACO new energy blueplanet TL3 125 | KACO blueplanet 87.0-165 TL3 | Relay control fault | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 128 | KACO blueplanet 87.0-165 TL3 | Internal memory error 1 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 150 | KACO blueplanet 87.0-165 TL3 | Protective shutdown drop reference ADC | has_event_class c4 verified · fact |
| KACO new energy blueplanet TL3 160 | KACO blueplanet 87.0-165 TL3 | Error: Grid relay L1 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 161 | KACO blueplanet 87.0-165 TL3 | Error: Grid relay L2 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 162 | KACO blueplanet 87.0-165 TL3 | Error: Grid relay L3 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 164 | KACO blueplanet 87.0-165 TL3 | Error: Filter relay L1 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 165 | KACO blueplanet 87.0-165 TL3 | Error: Filter relay L2 | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 169 | KACO blueplanet 87.0-165 TL3 | Error: AFI sensor | has_event_class c4 verified · fact |
| KACO new energy blueplanet TL3 180 | KACO blueplanet 87.0-165 TL3 | Pre-synchronisation not pos-sible | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 181 | KACO blueplanet 87.0-165 TL3 | Insulation error, centre | has_event_class c5 drafted · lead |
| KACO new energy blueplanet TL3 188 | KACO blueplanet 87.0-165 TL3 | Semiconductor test not pos-sible | has_event_class c6 drafted · lead |
| KACO new energy blueplanet TL3 189 | KACO blueplanet 87.0-165 TL3 | Semiconductor module 1 in channel A defective | has_event_class c7 drafted · lead |
| KACO new energy blueplanet TL3 203 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage (effective value) L1 | has_event_class c6 drafted · lead |
| KACO new energy blueplanet TL3 204 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage (effective value) L2 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 205 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage (effective value) L3 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 206 | KACO blueplanet 87.0-165 TL3 | Protection shutdown over-current HW | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 207 | KACO blueplanet 87.0-165 TL3 | Detection of hardware de-tection failed: Control card | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 208 | KACO blueplanet 87.0-165 TL3 | Detection of hardware de-tection failed: AC power board | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 209 | KACO blueplanet 87.0-165 TL3 | Detection of hardware de-tection failed: AC relay board | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 216 | KACO blueplanet 87.0-165 TL3 | Protect. shutdown HW - overvoltage DC link halves | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 217 | KACO blueplanet 87.0-165 TL3 | Protect. shutdown HW - 24V supply voltage | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 35 | KACO blueplanet 87.0-165 TL3 | Protect. shutdown SW | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 50 | KACO blueplanet 87.0-165 TL3 | Grid failure average voltage | has_event_class c3 verified · fact |
| KACO new energy blueplanet TL3 59 | KACO blueplanet 87.0-165 TL3 | Self test error | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 67 | KACO blueplanet 87.0-165 TL3 | Fehler Leistungsteil 1 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 73 | KACO blueplanet 87.0-165 TL3 | Standalone grid error | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 78 | KACO blueplanet 87.0-165 TL3 | Resid. current shutdown (AFI) | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 80 | KACO blueplanet 87.0-165 TL3 | Insulation meas. not pos-sible | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 81 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage L1 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 82 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage L2 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 83 | KACO blueplanet 87.0-165 TL3 | Protection shutdown grid voltage L3 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 84 | KACO blueplanet 87.0-165 TL3 | Protection shutdown DC link undervoltage | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 85 | KACO blueplanet 87.0-165 TL3 | Protection shutdown DC link overvoltage | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 86 | KACO blueplanet 87.0-165 TL3 | Protect. shutdown unbal. DC link | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 87 | KACO blueplanet 87.0-165 TL3 | Protection shutdown over-current L1 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 88 | KACO blueplanet 87.0-165 TL3 | Protection shutdown over-current L2 | has_event_class c3 drafted · lead |
| KACO new energy blueplanet TL3 89 | KACO blueplanet 87.0-165 TL3 | Protection shutdown over-current L3 | has_event_class c3 verified · fact |
| KACO new energy blueplanet TL3 91 | KACO blueplanet 87.0-165 TL3 | Protective shutdown drop 2.5 V | has_event_class c2 drafted · lead |
| KACO new energy blueplanet TL3 97 | KACO blueplanet 87.0-165 TL3 | Protection shutdown over-current HW | has_event_class c3 drafted · lead |
SMA
| Code | Family | Shown as | Claim |
|---|---|---|---|
| SMA SB-US-40 101-105 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Grid fault | has_event_class c4 drafted · lead |
| SMA SB-US-40 1302 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | has_event_class c9 drafted · lead | |
| SMA SB-US-40 1501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Reconnection fault grid | has_event_class c5 drafted · lead |
| SMA SB-US-40 202-206 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Grid fault | has_event_class c6 drafted · lead |
| SMA SB-US-40 3401-3407 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | DC overvoltage > Disconnect generator | has_event_class c8 drafted · lead |
| SMA SB-US-40 3501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Insulation failure > Check generator | has_event_class c14 verified · fact |
| SMA SB-US-40 3601 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | High discharge curr. > Check generator | has_event_class c7 drafted · lead |
| SMA SB-US-40 3701 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Resid.curr.too.high > Check generator | has_event_class c11 drafted · lead |
| SMA SB-US-40 401-404 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Grid fault | has_event_class c3 drafted · lead |
| SMA SB-US-40 4301 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Electric arc detected > Check DC generator | has_event_class c10 drafted · lead |
| SMA SB-US-40 501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Grid fault | has_event_class c3 drafted · lead |
| SMA SB-US-40 701 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Frq. not permitted > Check parameter | has_event_class c3 drafted · lead |
| SMA SB-US-40 8206 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Electr. arc detected > Please confirm by tapping | has_event_class c8 drafted · lead |
| SMA SB-US-41 101 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c7 drafted · lead |
| SMA SB-US-41 102 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c4 drafted · lead |
| SMA SB-US-41 0103 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c4 drafted · lead |
| SMA SB-US-41 105 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c4 verified · fact |
| SMA SB-US-41 1302 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | has_event_class c9 drafted · lead | |
| SMA SB-US-41 1501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Reconnection fault grid | has_event_class c5 drafted · lead |
| SMA SB-US-41 202 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c6 drafted · lead |
| SMA SB-US-41 0203 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c9 drafted · lead |
| SMA SB-US-41 0205 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c9 drafted · lead |
| SMA SB-US-41 206 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c6 drafted · lead |
| SMA SB-US-41 301 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c3 drafted · lead |
| SMA SB-US-41 3301 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Unstable operation | has_event_class c5 drafted · lead |
| SMA SB-US-41 3303 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Unstable operation | has_event_class c5 drafted · lead |
| SMA SB-US-41 3401 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SB-US-41 3402 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SB-US-41 3407 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SB-US-41 3501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Insulation failure > Check generator | has_event_class c14 drafted · lead |
| SMA SB-US-41 3601 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | High discharge current > Check generator | has_event_class c7 drafted · lead |
| SMA SB-US-41 3701 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Residual current too high > Check generator | has_event_class c11 drafted · lead |
| SMA SB-US-41 401 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c3 drafted · lead |
| SMA SB-US-41 404 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c6 drafted · lead |
| SMA SB-US-41 4301 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | has_event_class c10 drafted · lead | |
| SMA SB-US-41 501 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Grid incident | has_event_class c3 drafted · lead |
| SMA SB-US-41 701 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Frequency not permitted > Check parameter | has_event_class c3 drafted · lead |
| SMA SB-US-41 8206 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Electric arc detected | has_event_class c8 drafted · lead |
| SMA SBSE-US-50 101 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c7 verified · fact |
| SMA SBSE-US-50 102 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 0103 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 105 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 1302 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | has_event_class c9 drafted · lead | |
| SMA SBSE-US-50 1501 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Reconnection fault grid | has_event_class c5 drafted · lead |
| SMA SBSE-US-50 202 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c6 drafted · lead |
| SMA SBSE-US-50 0203 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c9 drafted · lead |
| SMA SBSE-US-50 206 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c6 drafted · lead |
| SMA SBSE-US-50 301 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 3302 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Unstable operation | has_event_class c5 verified · fact |
| SMA SBSE-US-50 3303 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Unstable operation | has_event_class c5 drafted · lead |
| SMA SBSE-US-50 3401 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | DC overvoltage > Disconnecting generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3402 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | DC overvoltage > Disconnecting generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3407 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3410 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3411 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | DC overvoltage > Disconnect generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3501 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Ground fault > Check generator | has_event_class c15 verified · fact |
| SMA SBSE-US-50 3601 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | High leakage current > Check generator | has_event_class c7 drafted · lead |
| SMA SBSE-US-50 3701 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Residual current too high > Check generator | has_event_class c11 drafted · lead |
| SMA SBSE-US-50 401 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 404 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c6 drafted · lead |
| SMA SBSE-US-50 4301 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | has_event_class c10 drafted · lead | |
| SMA SBSE-US-50 501 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 6001-6499 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Interference device | has_event_class c4 verified · fact |
| SMA SBSE-US-50 6501 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Overtemperature | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 6502 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Overtemperature | has_event_class c6 drafted · lead |
| SMA SBSE-US-50 6509 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Overtemperature | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 6633 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Device fault | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 7001 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 7002 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 701 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Frequency not permitted > Check parameter | has_event_class c3 drafted · lead |
| SMA SBSE-US-50 7015 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA SBSE-US-50 7702 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Interference device | has_event_class c9 drafted · lead |
| SMA SBSE-US-50 7703 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Self-diagnosis > Interference device | has_event_class c5 drafted · lead |
| SMA SBSE-US-50 9102 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Permanent operation inhibition | has_event_class c3 drafted · lead |
| SMA PEAK3-US 1302 | Sunny Highpower PEAK3 (SHP 125-172-US) | has_event_class c9 drafted · lead | |
| SMA PEAK3-US 1501 | Sunny Highpower PEAK3 (SHP 125-172-US) | Reconnection fault grid | has_event_class c5 drafted · lead |
| SMA PEAK3-US 3501 | Sunny Highpower PEAK3 (SHP 125-172-US) | Insulation failure > Check generator | has_event_class c14 drafted · lead |
| SMA PEAK3-US 3601 | Sunny Highpower PEAK3 (SHP 125-172-US) | High discharge current > Check generator | has_event_class c7 drafted · lead |
| SMA PEAK3-US 3701 | Sunny Highpower PEAK3 (SHP 125-172-US) | Residual current too high > Check generator | has_event_class c11 drafted · lead |
| SMA PEAK3-US 501 | Sunny Highpower PEAK3 (SHP 125-172-US) | Grid incident | has_event_class c3 drafted · lead |
| SMA PEAK3-US 0502 | Sunny Highpower PEAK3 (SHP 125-172-US) | Grid incident | has_event_class c6 drafted · lead |
| SMA PEAK3-US 0503 | Sunny Highpower PEAK3 (SHP 125-172-US) | Grid incident | has_event_class c7 drafted · lead |
| SMA PEAK3-US 6001-6499 | Sunny Highpower PEAK3 (SHP 125-172-US) | Self-diagnosis > Interference device | has_event_class c4 drafted · lead |
| SMA PEAK3-US 6438 | Sunny Highpower PEAK3 (SHP 125-172-US) | has_event_class c5 drafted · lead | |
| SMA PEAK3-US 6501 | Sunny Highpower PEAK3 (SHP 125-172-US) | Self-diagnosis > Overtemperature | has_event_class c3 drafted · lead |
| SMA PEAK3-US 7001 | Sunny Highpower PEAK3 (SHP 125-172-US) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA PEAK3-US 701 | Sunny Highpower PEAK3 (SHP 125-172-US) | Frequency not permitted > Check parameter | has_event_class c3 drafted · lead |
| SMA CORE1-US 101 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Grid incident | has_event_class c7 drafted · lead |
| SMA CORE1-US 301 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Grid incident | has_event_class c5 drafted · lead |
| SMA CORE1-US 3401 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c9 drafted · lead |
| SMA CORE1-US 3402 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3404 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3407 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3410 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3411 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3412 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | DC overvoltage > Disconnect PV array | has_event_class c7 drafted · lead |
| SMA CORE1-US 3501 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Insulation failure > Check generator | has_event_class c16 verified · fact |
| SMA CORE1-US 3701 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Residual current too high > Check PV array | has_event_class c13 drafted · lead |
| SMA CORE1-US 401 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Grid incident | has_event_class c5 drafted · lead |
| SMA CORE1-US 4301 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c13 drafted · lead | |
| SMA CORE1-US 501 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Grid incident | has_event_class c5 drafted · lead |
| SMA CORE1-US 6107 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c3 drafted · lead | |
| SMA CORE1-US 6502 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c8 drafted · lead | |
| SMA CORE1-US 7622 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c7 verified · fact | |
| SMA CORE1-US 7702 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Device fault | has_event_class c9 drafted · lead |
| SMA CORE1-US 8206 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c8 drafted · lead | |
| SMA STP-TL-US 101-103 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Grid fault | has_event_class c4 drafted · lead |
| SMA STP-TL-US 1302 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c9 drafted · lead | |
| SMA STP-TL-US 1501 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c5 drafted · lead | |
| SMA STP-TL-US 202-203 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Grid fault | has_event_class c5 verified · fact |
| SMA STP-TL-US 301 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c3 drafted · lead | |
| SMA STP-TL-US 3301 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Unstable operation > Generator output too low | has_event_class c5 drafted · lead |
| SMA STP-TL-US 3302 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Unstable operation > Abort self-test | has_event_class c5 drafted · lead |
| SMA STP-TL-US 3303 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Unstable operation > Data storage blocked | has_event_class c5 drafted · lead |
| SMA STP-TL-US 3401-3402 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | DC overvoltage > Disconnect generator | has_event_class c6 drafted · lead |
| SMA STP-TL-US 3501 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c14 drafted · lead | |
| SMA STP-TL-US 3601 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | High discharge curr. > Check generator | has_event_class c7 drafted · lead |
| SMA STP-TL-US 3701 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Resid.curr.too.high > Check generator | has_event_class c12 drafted · lead |
| SMA STP-TL-US 401 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c3 drafted · lead | |
| SMA STP-TL-US 404 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c6 drafted · lead | |
| SMA STP-TL-US 4301 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c10 drafted · lead | |
| SMA STP-TL-US 501 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c3 drafted · lead | |
| SMA STP-TL-US 6501-6511 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Self diagnosis > Interference device | has_event_class c6 drafted · lead |
| SMA STP-TL-US 701 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c3 drafted · lead | |
| SMA STP-TL-US 8206 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | Electr. arc detected > Please confirm by tapping | has_event_class c8 drafted · lead |
| SMA STP-X-US 101 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c7 drafted · lead |
| SMA STP-X-US 102 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA STP-X-US 0103 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA STP-X-US 105 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c4 drafted · lead |
| SMA STP-X-US 1302 | Sunny Tripower X 13-30-US (STP xx-US-50) | has_event_class c9 drafted · lead | |
| SMA STP-X-US 1501 | Sunny Tripower X 13-30-US (STP xx-US-50) | Reconnection fault grid | has_event_class c5 verified · fact |
| SMA STP-X-US 301 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA STP-X-US 3501 | Sunny Tripower X 13-30-US (STP xx-US-50) | Insulation failure > Check generator | has_event_class c14 drafted · lead |
| SMA STP-X-US 3601 | Sunny Tripower X 13-30-US (STP xx-US-50) | High discharge current > Check generator | has_event_class c7 drafted · lead |
| SMA STP-X-US 3701 | Sunny Tripower X 13-30-US (STP xx-US-50) | Residual current too high > Check generator | has_event_class c11 drafted · lead |
| SMA STP-X-US 401 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA STP-X-US 404 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c6 drafted · lead |
| SMA STP-X-US 4301 | Sunny Tripower X 13-30-US (STP xx-US-50) | has_event_class c10 drafted · lead | |
| SMA STP-X-US 501 | Sunny Tripower X 13-30-US (STP xx-US-50) | Grid incident | has_event_class c3 drafted · lead |
| SMA STP-X-US 6001-6499 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c4 drafted · lead |
| SMA STP-X-US 6101 | Sunny Tripower X 13-30-US (STP xx-US-50) | Interference device / DevFlt > Self-diagnosis/ SlfDiag | has_event_class c3 drafted · lead |
| SMA STP-X-US 6107 | Sunny Tripower X 13-30-US (STP xx-US-50) | has_event_class c3 drafted · lead | |
| SMA STP-X-US 6202 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c4 drafted · lead |
| SMA STP-X-US 6401 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c5 drafted · lead |
| SMA STP-X-US 6404 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c3 drafted · lead |
| SMA STP-X-US 6422 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c6 drafted · lead |
| SMA STP-X-US 6438 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Interference device | has_event_class c5 drafted · lead |
| SMA STP-X-US 6501 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis > Overtemperature | has_event_class c3 drafted · lead |
| SMA STP-X-US 7001 | Sunny Tripower X 13-30-US (STP xx-US-50) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA STP-X-US 701 | Sunny Tripower X 13-30-US (STP xx-US-50) | Frequency not permitted > Check parameter | has_event_class c3 drafted · lead |
| SMA STP-X-US 7015 | Sunny Tripower X 13-30-US (STP xx-US-50) | Fault sensor interior temperature | has_event_class c4 drafted · lead |
| SMA STP-X-US 7702 | Sunny Tripower X 13-30-US (STP xx-US-50) | has_event_class c9 drafted · lead | |
| SMA STP-X-US 7703 | Sunny Tripower X 13-30-US (STP xx-US-50) | Self-diagnosis / SlfDiag > Interference device / DevFlt | has_event_class c5 drafted · lead |
| SMA SC-CP-XT 0103 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 0203 | Sunny Central 500CP XT-1000CP XT | has_event_class c9 drafted · lead | |
| SMA SC-CP-XT 0205 | Sunny Central 500CP XT-1000CP XT | has_event_class c9 drafted · lead | |
| SMA SC-CP-XT 3404 | Sunny Central 500CP XT-1000CP XT | has_event_class c7 drafted · lead | |
| SMA SC-CP-XT 3501 | Sunny Central 500CP XT-1000CP XT | has_event_class c14 drafted · lead | |
| SMA SC-CP-XT 3601 | Sunny Central 500CP XT-1000CP XT | has_event_class c7 drafted · lead | |
| SMA SC-CP-XT 404 | Sunny Central 500CP XT-1000CP XT | has_event_class c6 drafted · lead | |
| SMA SC-CP-XT 0502 | Sunny Central 500CP XT-1000CP XT | has_event_class c6 drafted · lead | |
| SMA SC-CP-XT 0503 | Sunny Central 500CP XT-1000CP XT | has_event_class c7 drafted · lead | |
| SMA SC-CP-XT 6404 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 6410 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 6417 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 6418 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 6422 | Sunny Central 500CP XT-1000CP XT | has_event_class c6 verified · fact | |
| SMA SC-CP-XT 6423 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 6425 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 6427 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 6441 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 6443 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 6447 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 6501 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 6502 | Sunny Central 500CP XT-1000CP XT | has_event_class c6 drafted · lead | |
| SMA SC-CP-XT 6605 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 7001 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 7002 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SC-CP-XT 9009 | Sunny Central 500CP XT-1000CP XT | has_event_class c4 drafted · lead | |
| SMA SI-US E110 | Sunny Island 4548-US / 6048-US | Shutdown due to error | has_event_class c2 drafted · lead |
| SMA SI-US F109 | Sunny Island 4548-US / 6048-US | Transformer overtemperature | has_event_class c2 drafted · lead |
| SMA SI-US F113 | Sunny Island 4548-US / 6048-US | Overtemperature heat sink | has_event_class c2 drafted · lead |
| SMA SI-US F117 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F121 | Sunny Island 4548-US / 6048-US | Inverter overvoltage | has_event_class c2 drafted · lead |
| SMA SI-US F141 | Sunny Island 4548-US / 6048-US | Inverter undervoltage | has_event_class c2 drafted · lead |
| SMA SI-US F158 | Sunny Island 4548-US / 6048-US | Voltage on output AC1 | has_event_class c2 drafted · lead |
| SMA SI-US F201 | Sunny Island 4548-US / 6048-US | Measuring range of battery voltage exceeded | has_event_class c2 drafted · lead |
| SMA SI-US F206 | Sunny Island 4548-US / 6048-US | Battery overtemperature | has_event_class c2 drafted · lead |
| SMA SI-US F208 | Sunny Island 4548-US / 6048-US | Battery overvoltage error | has_event_class c2 drafted · lead |
| SMA SI-US F213 | Sunny Island 4548-US / 6048-US | Warning low battery voltage | has_event_class c2 drafted · lead |
| SMA SI-US F221 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F314 | Sunny Island 4548-US / 6048-US | External voltage failure | has_event_class c2 drafted · lead |
| SMA SI-US F605 | Sunny Island 4548-US / 6048-US | Transfer relay does not open | has_event_class c2 drafted · lead |
| SMA SI-US F702 | Sunny Island 4548-US / 6048-US | DSP reset | has_event_class c2 drafted · lead |
| SMA SI-US F703 | Sunny Island 4548-US / 6048-US | Timeout during a task | has_event_class c2 drafted · lead |
| SMA SI-US F704 | Sunny Island 4548-US / 6048-US | Invalid DSP calibration | has_event_class c2 drafted · lead |
| SMA SI-US F706 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F710 | Sunny Island 4548-US / 6048-US | Autostart meter elapsed (several autostarts in succession) | has_event_class c2 drafted · lead |
| SMA SI-US F716 | Sunny Island 4548-US / 6048-US | Measuring range of battery voltage exceeded | has_event_class c2 drafted · lead |
| SMA SI-US F720 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F721 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F731 | Sunny Island 4548-US / 6048-US | Error in cluster configuration | has_event_class c2 drafted · lead |
| SMA SI-US F732 | Sunny Island 4548-US / 6048-US | Error in address assignment of cluster devices | has_event_class c2 drafted · lead |
| SMA SI-US F733 | Sunny Island 4548-US / 6048-US | No message from cluster master (only slave) | has_event_class c2 drafted · lead |
| SMA SI-US F739 | Sunny Island 4548-US / 6048-US | Internal communication of the master is interrupted | has_event_class c2 drafted · lead |
| SMA SI-US F743 | Sunny Island 4548-US / 6048-US | Internal CAN communication of the master is interrupted | has_event_class c2 drafted · lead |
| SMA SI-US F754 | Sunny Island 4548-US / 6048-US | Communication with Multicluster Box interrupted | has_event_class c2 drafted · lead |
| SMA SI-US F758 | Sunny Island 4548-US / 6048-US | No output voltage measured from the main cluster | has_event_class c2 drafted · lead |
| SMA SI-US F781 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F782 | Sunny Island 4548-US / 6048-US | Failure of the grid monitoring | has_event_class c2 drafted · lead |
| SMA SI-US F783 | Sunny Island 4548-US / 6048-US | Slave does not receive a Syncpuls | has_event_class c2 drafted · lead |
| SMA SI-US F801 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F806 | Sunny Island 4548-US / 6048-US | Multicluster Box settings do not match software settings. | has_event_class c2 drafted · lead |
| SMA SI-US F809 | Sunny Island 4548-US / 6048-US | Error Q10 contactor (load shedding) | has_event_class c2 drafted · lead |
| SMA SI-US F810 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F811 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F816 | Sunny Island 4548-US / 6048-US | Error Q7 contactor | has_event_class c2 drafted · lead |
| SMA SI-US F817 | Sunny Island 4548-US / 6048-US | Error Q9 contactor | has_event_class c2 drafted · lead |
| SMA SI-US F818 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F890 | Sunny Island 4548-US / 6048-US | Interference at external measurement point of Multicluster Box | has_event_class c2 drafted · lead |
| SMA SI-US F891 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F892 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F893 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F920 | Sunny Island 4548-US / 6048-US | Error message via SiCom: General | has_event_class c2 drafted · lead |
| SMA SI-US F921 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Battery overvoltage | has_event_class c2 drafted · lead |
| SMA SI-US F922 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Battery undervoltage | has_event_class c2 drafted · lead |
| SMA SI-US F923 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Battery overtemperature | has_event_class c2 drafted · lead |
| SMA SI-US F924 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Battery undertemperature | has_event_class c2 drafted · lead |
| SMA SI-US F925 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F926 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F927 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F928 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F929 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Error in the battery | has_event_class c2 drafted · lead |
| SMA SI-US F930 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Short circuit | has_event_class c2 drafted · lead |
| SMA SI-US F931 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F932 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US F935 | Sunny Island 4548-US / 6048-US | Error message via SiCom: Error in the generator | has_event_class c2 drafted · lead |
| SMA SI-US F952 | Sunny Island 4548-US / 6048-US | Time for external battery management exceeded | has_event_class c2 drafted · lead |
Schneider Electric
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Schneider Electric CL125 014 | Schneider Electric Conext CL125 | Average grid over-voltage (10 minutes) | has_event_class c5 drafted · lead |
| Schneider Electric CL125 015 | Schneider Electric Conext CL125 | Grid impedance exceeds inverter's limit. | has_event_class c6 drafted · lead |
| Schneider Electric CL125 016 | Schneider Electric Conext CL125 | AC output overload | has_event_class c4 drafted · lead |
| Schneider Electric CL125 017 | Schneider Electric Conext CL125 | Grid voltage imbalance | has_event_class c5 drafted · lead |
| Schneider Electric CL125 019 | Schneider Electric Conext CL125 | High transient DC bus voltage | has_event_class c4 drafted · lead |
| Schneider Electric CL125 020 | Schneider Electric Conext CL125 | High DC bus voltage | has_event_class c4 drafted · lead |
| Schneider Electric CL125 022 | Schneider Electric Conext CL125 | Over current protection | has_event_class c4 drafted · lead |
| Schneider Electric CL125 023 | Schneider Electric Conext CL125 | PV configuration mode has changed during normal operation. | has_event_class c6 drafted · lead |
| Schneider Electric CL125 043 | Schneider Electric Conext CL125 | has_event_class c4 drafted · lead | |
| Schneider Electric CL125 047 | Schneider Electric Conext CL125 | has_event_class c6 verified · fact | |
| Schneider Electric CL125 070 | Schneider Electric Conext CL125 | Fan event | has_event_class c7 drafted · lead |
Solis
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Solis 1P-4G-US AFCI Check FAULT | Solis-1P(3.6-10)K-4G-US | has_event_class c8 drafted · lead | |
| Solis 1P-4G-US INI-FAULT | Solis-1P(3.6-10)K-4G-US | Ini aliza on Protec on | has_event_class c7 drafted · lead |
| Solis 1P-4G-US OV-TEM | Solis-1P(3.6-10)K-4G-US | Temperature Protec on | has_event_class c11 drafted · lead |
| Solis 1P-4G-US PV ISO-PRO 01/02 | Solis-1P(3.6-10)K-4G-US | Ground Protec on | has_event_class c11 drafted · lead |
| Solis 1P-4G-US UN-BUS | Solis-1P(3.6-10)K-4G-US | DC BUS voltage is too low | has_event_class c8 drafted · lead |
| Solis 3P-5G-US 12Power-FAULT | Solis-3P(125-255)K-EHV-5G-US | 12V power supply fault | has_event_class c6 drafted · lead |
| Solis 3P-5G-US DCInj-Fault | Solis-3P(125-255)K-EHV-5G-US | High DC injection current | has_event_class c7 drafted · lead |
| Solis 3P-5G-US DSP-B-Fault | Solis-3P(125-255)K-EHV-5G-US | Comm. failure between main and slave DSP | has_event_class c6 drafted · lead |
| Solis 3P-5G-US IG-AD | Solis-3P(125-255)K-EHV-5G-US | Grid current sampling fail | has_event_class c7 drafted · lead |
| Solis 3P-5G-US IGBT-OV-I | Solis-3P(125-255)K-EHV-5G-US | Over IGBT current | has_event_class c8 drafted · lead |
| Solis 3P-5G-US INI-FAULT | Solis-3P(125-255)K-EHV-5G-US | Initialization system fault | has_event_class c6 drafted · lead |
| Solis 3P-5G-US OV-DCA-I | Solis-3P(125-255)K-EHV-5G-US | DC input overcurrent | has_event_class c8 drafted · lead |
| Solis 3P-5G-US OV-TEM | Solis-3P(125-255)K-EHV-5G-US | Over Temperature | has_event_class c10 drafted · lead |
| Solis 3P-5G-US PV ISO-PRO 01/02 | Solis-3P(125-255)K-EHV-5G-US | PV isolation protection | has_event_class c10 drafted · lead |
| Solis 3P-5G-US RelayChk-Fail | Solis-3P(125-255)K-EHV-5G-US | Relay check fail | has_event_class c6 drafted · lead |
| Solis 3P-5G-US UN-BUS01/02 | Solis-3P(125-255)K-EHV-5G-US | Under DC bus voltage | has_event_class c5 drafted · lead |
| Solis 3P-5G-US UN-G-F01/02 | Solis-3P(125-255)K-EHV-5G-US | Under grid frequency | has_event_class c4 drafted · lead |
| Solis 3P-5G-US UN-G-V01/02 | Solis-3P(125-255)K-EHV-5G-US | Under grid voltage | has_event_class c4 drafted · lead |
| Solis RHI-1P-HV 12Power-FAULT | Solis RHI-1P(5-10)K-HVES-5G-US | 12V power supply fault | has_event_class c6 drafted · lead |
| Solis RHI-1P-HV AFCI Check FAULT | Solis RHI-1P(5-10)K-HVES-5G-US | AFCI module self check fault | has_event_class c7 drafted · lead |
| Solis RHI-1P-HV DCInj-Fault | Solis RHI-1P(5-10)K-HVES-5G-US | High DC injection current | has_event_class c7 drafted · lead |
| Solis RHI-1P-HV DSP-B-Fault | Solis RHI-1P(5-10)K-HVES-5G-US | Comm. failure between main and slave DSP | has_event_class c6 drafted · lead |
| Solis RHI-1P-HV IG-AD | Solis RHI-1P(5-10)K-HVES-5G-US | Grid current sampling fail | has_event_class c7 drafted · lead |
| Solis RHI-1P-HV IGBT-OV-I | Solis RHI-1P(5-10)K-HVES-5G-US | Over IGBT current | has_event_class c8 drafted · lead |
| Solis RHI-1P-HV INI-FAULT | Solis RHI-1P(5-10)K-HVES-5G-US | Initialization system fault | has_event_class c6 drafted · lead |
| Solis RHI-1P-HV OV-DCA-I | Solis RHI-1P(5-10)K-HVES-5G-US | DC input overcurrent | has_event_class c8 drafted · lead |
| Solis RHI-1P-HV OV-IgTr | Solis RHI-1P(5-10)K-HVES-5G-US | AC side transient overcurrent | has_event_class c6 drafted · lead |
| Solis RHI-1P-HV OV-TEM | Solis RHI-1P(5-10)K-HVES-5G-US | Over Temperature | has_event_class c10 drafted · lead |
| Solis RHI-1P-HV PV ISO-PRO 01/02 | Solis RHI-1P(5-10)K-HVES-5G-US | PV isolation protection | has_event_class c10 drafted · lead |
| Solis RHI-1P-HV RelayChk-Fail | Solis RHI-1P(5-10)K-HVES-5G-US | Relay check fail | has_event_class c6 drafted · lead |
| Solis RHI-1P-HV UN-BUS01/02 | Solis RHI-1P(5-10)K-HVES-5G-US | Under DC bus voltage | has_event_class c5 drafted · lead |
| Solis RHI-1P-HV UN-G-F01/02 | Solis RHI-1P(5-10)K-HVES-5G-US | Under grid frequency | has_event_class c4 drafted · lead |
| Solis RHI-1P-HV UN-G-V01/02 | Solis RHI-1P(5-10)K-HVES-5G-US | Under grid voltage | has_event_class c4 drafted · lead |
| Solis S5-GC ARC-FAULT | Solis S5-GC(75-125)K-US | has_event_class c11 verified · fact | |
| Solis S5-GC INI-FAULT | Solis S5-GC(75-125)K-US | Initialization Protect ion | has_event_class c6 verified · fact |
| Solis S5-GC OV-TEM | Solis S5-GC(75-125)K-US | Temperature Protect ion | has_event_class c10 verified · fact |
| Solis S5-GC PV ISO-PRO 01/02 | Solis S5-GC(75-125)K-US | Ground Protect ion | has_event_class c10 verified · fact |
| Solis S5-GC UN-BUS | Solis S5-GC(75-125)K-US | DC BUS voltage is too low | has_event_class c7 drafted · lead |
| Solis S6-EH1P 12Power-FAULT | Solis S6-EH1P(3.8-11.4)K-H-US | 12V power supply fault | has_event_class c6 drafted · lead |
| Solis S6-EH1P AFCI Check FAULT | Solis S6-EH1P(3.8-11.4)K-H-US | AFCI module self check fault | has_event_class c7 drafted · lead |
| Solis S6-EH1P DCInj-Fault | Solis S6-EH1P(3.8-11.4)K-H-US | High DC injection current | has_event_class c7 verified · fact |
| Solis S6-EH1P DSP-B-Fault | Solis S6-EH1P(3.8-11.4)K-H-US | Comm. failure between main and slave DSP | has_event_class c6 drafted · lead |
| Solis S6-EH1P IG-AD | Solis S6-EH1P(3.8-11.4)K-H-US | Grid current sampling fail | has_event_class c7 drafted · lead |
| Solis S6-EH1P IGBT-OV-I | Solis S6-EH1P(3.8-11.4)K-H-US | Over IGBT current | has_event_class c8 drafted · lead |
| Solis S6-EH1P INI-FAULT | Solis S6-EH1P(3.8-11.4)K-H-US | Initialization system fault | has_event_class c6 drafted · lead |
| Solis S6-EH1P OV-DCA-I | Solis S6-EH1P(3.8-11.4)K-H-US | DC input overcurrent | has_event_class c8 drafted · lead |
| Solis S6-EH1P OV-IgTr | Solis S6-EH1P(3.8-11.4)K-H-US | AC side transient overcurrent | has_event_class c6 drafted · lead |
| Solis S6-EH1P OV-TEM | Solis S6-EH1P(3.8-11.4)K-H-US | Over Temperature | has_event_class c10 drafted · lead |
| Solis S6-EH1P PV ISO-PRO 01/02 | Solis S6-EH1P(3.8-11.4)K-H-US | PV isolation protection | has_event_class c10 drafted · lead |
| Solis S6-EH1P RelayChk-Fail | Solis S6-EH1P(3.8-11.4)K-H-US | Relay check fail | has_event_class c6 drafted · lead |
| Solis S6-EH1P UN-BUS01/02 | Solis S6-EH1P(3.8-11.4)K-H-US | Under DC bus voltage | has_event_class c5 drafted · lead |
| Solis S6-EH1P UN-G-F01/02 | Solis S6-EH1P(3.8-11.4)K-H-US | Under grid frequency | has_event_class c4 drafted · lead |
| Solis S6-EH1P UN-G-V01/02 | Solis S6-EH1P(3.8-11.4)K-H-US | Under grid voltage | has_event_class c4 drafted · lead |
| Solis S6-EH2P 12Power-FAULT | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | 12V undervoltage failure | has_event_class c6 drafted · lead |
| Solis S6-EH2P AFCI-Check | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | AFCI self-test failure | has_event_class c7 drafted · lead |
| Solis S6-EH2P DCInj-Fault | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | The current DC component exceeds the limit | has_event_class c7 drafted · lead |
| Solis S6-EH2P DSP-B-Fault | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | The master-slave DSP communication is abnormal | has_event_class c6 verified · fact |
| Solis S6-EH2P G-F-GLU | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage frequency f luctuat ion | has_event_class c3 drafted · lead |
| Solis S6-EH2P GRID-INTF02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Power grid disturbance 02 | has_event_class c6 drafted · lead |
| Solis S6-EH2P IGBT-OV-I | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | IGBT overcurrent | has_event_class c8 drafted · lead |
| Solis S6-EH2P ILeak-Check | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Leakage current sensor fai lure | has_event_class c8 drafted · lead |
| Solis S6-EH2P ILeak-PRO01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Leakage current failure 01 (30mA) | has_event_class c5 drafted · lead |
| Solis S6-EH2P ILeak-PRO02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Leakage current failure 02 (60mA) | has_event_class c5 drafted · lead |
| Solis S6-EH2P ILeak-PRO03 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Leakage current failure 03 (150mA) | has_event_class c5 drafted · lead |
| Solis S6-EH2P ILeak-PRO04 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Leakage current failure 04 | has_event_class c5 drafted · lead |
| Solis S6-EH2P INI-FAULT | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | AD zero drift overlink | has_event_class c6 drafted · lead |
| Solis S6-EH2P OV-BUS-H | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Battery overvoltage hardware failure / VBUS | has_event_class c5 drafted · lead |
| Solis S6-EH2P OV-DC02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | DC 2 input overvoltage | has_event_class c6 drafted · lead |
| Solis S6-EH2P OV-DCA-I | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | DC 1 average overcurrent | has_event_class c8 drafted · lead |
| Solis S6-EH2P OV-DCB-I | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | DC 2 average overcurrent | has_event_class c6 drafted · lead |
| Solis S6-EH2P OV-G-F01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid frequency exceeds the upper frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH2P OV-G-F02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid frequency exceeds the upper frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH2P OV-G-V01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage exceeds the upper voltage range | has_event_class c6 drafted · lead |
| Solis S6-EH2P OV-G-V02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid transient overvoltage | has_event_class c3 drafted · lead |
| Solis S6-EH2P OV-G-V03 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid transient overvoltage | has_event_class c3 drafted · lead |
| Solis S6-EH2P OV-G-V04 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage exceeds the upper voltage range | has_event_class c3 verified · fact |
| Solis S6-EH2P OV-G-V05 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage RMS instanta-neous overvoltage fault | has_event_class c3 drafted · lead |
| Solis S6-EH2P OV-TEM | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Module over temperature | has_event_class c10 drafted · lead |
| Solis S6-EH2P PV ISO-PRO01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | PV negative ground fault | has_event_class c8 verified · fact |
| Solis S6-EH2P PV ISO-PRO02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | PV positive ground fault | has_event_class c8 drafted · lead |
| Solis S6-EH2P RelayChk-Fail | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Relay failure | has_event_class c6 drafted · lead |
| Solis S6-EH2P Surge Alarm | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | On-site grid surge | has_event_class c4 verified · fact |
| Solis S6-EH2P UNB-BUS | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | DC bus unbalanced voltage | has_event_class c4 verified · fact |
| Solis S6-EH2P UN-BUS01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | DC bus undervoltage | has_event_class c4 drafted · lead |
| Solis S6-EH2P UN-BUS02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Abnormal detection of DC bus voltage | has_event_class c4 drafted · lead |
| Solis S6-EH2P UN-G-F01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid frequency exceeds the lower frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH2P UN-G-F02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid frequency exceeds the lower frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH2P UN-G-V01 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage exceeds the lower voltage range | has_event_class c6 drafted · lead |
| Solis S6-EH2P UN-G-V02 | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Grid voltage exceeds the lower voltage range | has_event_class c3 drafted · lead |
| Solis S6-EH2P UN-TEM | Solis S6-EH2P(9.6-16)K-SV-YD-L-US | Low temperature protection | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K 12Power-FAULT | Solis S6-EH3P(30-60)K-NV-YD-H-US | 12V undervoltage failure | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K AFCI-Check | Solis S6-EH3P(30-60)K-NV-YD-H-US | AFCI self-test failure | has_event_class c8 drafted · lead |
| Solis S6-EH3P30-60K DCInj-Fault | Solis S6-EH3P(30-60)K-NV-YD-H-US | The current DC component exceeds the limit | has_event_class c8 drafted · lead |
| Solis S6-EH3P30-60K DSP-B-Fault | Solis S6-EH3P(30-60)K-NV-YD-H-US | The master-slave DSP communication is abnormal | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K G-F-GLU | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage frequency f luctuat ion | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K GRID-INTF02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Power grid disturbance 02 | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K IGBT-OV-I | Solis S6-EH3P(30-60)K-NV-YD-H-US | IGBT overcurrent | has_event_class c9 drafted · lead |
| Solis S6-EH3P30-60K ILeak-Check | Solis S6-EH3P(30-60)K-NV-YD-H-US | Leakage current sensor fai lure | has_event_class c9 drafted · lead |
| Solis S6-EH3P30-60K ILeak-PRO01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Leakage current failure 01 (30mA) | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K ILeak-PRO02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Leakage current failure 02 (60mA) | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K ILeak-PRO03 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Leakage current failure 03 (150mA) | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K ILeak-PRO04 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Leakage current failure 04 | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K INI-FAULT | Solis S6-EH3P(30-60)K-NV-YD-H-US | AD zero drift overlink | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K OV-BUS-H | Solis S6-EH3P(30-60)K-NV-YD-H-US | Battery overvoltage hardware failure / VBUS | has_event_class c6 drafted · lead |
| Solis S6-EH3P30-60K OV-DC02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | DC 2 input overvoltage | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K OV-DCA-I | Solis S6-EH3P(30-60)K-NV-YD-H-US | DC 1 average overcurrent | has_event_class c9 drafted · lead |
| Solis S6-EH3P30-60K OV-DCB-I | Solis S6-EH3P(30-60)K-NV-YD-H-US | DC 2 average overcurrent | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K OV-G-F01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid frequency exceeds the upper frequency range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-G-F02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid frequency exceeds the upper frequency range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-G-V01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage exceeds the upper voltage range | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K OV-G-V02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid transient overvoltage | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-G-V03 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid transient overvoltage | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-G-V04 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage exceeds the upper voltage range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-G-V05 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage RMS instanta-neous overvoltage fault | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K OV-TEM | Solis S6-EH3P(30-60)K-NV-YD-H-US | Module over temperature | has_event_class c11 drafted · lead |
| Solis S6-EH3P30-60K PV ISO-PRO01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | PV negative ground fault | has_event_class c9 drafted · lead |
| Solis S6-EH3P30-60K PV ISO-PRO02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | PV positive ground fault | has_event_class c9 drafted · lead |
| Solis S6-EH3P30-60K RelayChk-Fail | Solis S6-EH3P(30-60)K-NV-YD-H-US | Relay failure | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K Surge Alarm | Solis S6-EH3P(30-60)K-NV-YD-H-US | On-site grid surge | has_event_class c5 verified · fact |
| Solis S6-EH3P30-60K UNB-BUS | Solis S6-EH3P(30-60)K-NV-YD-H-US | DC bus unbalanced voltage | has_event_class c5 drafted · lead |
| Solis S6-EH3P30-60K UN-BUS01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | DC bus undervoltage | has_event_class c5 drafted · lead |
| Solis S6-EH3P30-60K UN-BUS02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Abnormal detection of DC bus voltage | has_event_class c5 drafted · lead |
| Solis S6-EH3P30-60K UN-G-F01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid frequency exceeds the lower frequency range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K UN-G-F02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid frequency exceeds the lower frequency range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K UN-G-V01 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage exceeds the lower voltage range | has_event_class c7 drafted · lead |
| Solis S6-EH3P30-60K UN-G-V02 | Solis S6-EH3P(30-60)K-NV-YD-H-US | Grid voltage exceeds the lower voltage range | has_event_class c4 drafted · lead |
| Solis S6-EH3P30-60K UN-TEM | Solis S6-EH3P(30-60)K-NV-YD-H-US | Low temperature protection | has_event_class c7 drafted · lead |
| Solis S6-EH3P75-150K 12Power-FAULT | Solis S6-EH3P(75-150)K10-NV-YD-H-US | 12V undervoltage failure | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K AFCI-Check | Solis S6-EH3P(75-150)K10-NV-YD-H-US | AFCI self-test failure | has_event_class c7 drafted · lead |
| Solis S6-EH3P75-150K DCInj-Fault | Solis S6-EH3P(75-150)K10-NV-YD-H-US | The current DC component exceeds the limit | has_event_class c7 drafted · lead |
| Solis S6-EH3P75-150K DSP-B-Fault | Solis S6-EH3P(75-150)K10-NV-YD-H-US | The primary-secondary DSP communication is abnormal | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K G-F-GLU | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage frequency f luctuat ion | has_event_class c3 verified · fact |
| Solis S6-EH3P75-150K GRID-INTF02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Power grid disturbance 02 | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K IGBT-OV-I | Solis S6-EH3P(75-150)K10-NV-YD-H-US | IGBT overcurrent | has_event_class c8 drafted · lead |
| Solis S6-EH3P75-150K ILeak-Check | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Leakage current sensor fai lure | has_event_class c8 drafted · lead |
| Solis S6-EH3P75-150K ILeak-PRO01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Leakage current failure 01 (30mA) | has_event_class c5 drafted · lead |
| Solis S6-EH3P75-150K ILeak-PRO02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Leakage current failure 02 (60mA) | has_event_class c5 drafted · lead |
| Solis S6-EH3P75-150K ILeak-PRO03 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Leakage current failure 03 (150mA) | has_event_class c5 drafted · lead |
| Solis S6-EH3P75-150K ILeak-PRO04 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Leakage current failure 04 | has_event_class c5 drafted · lead |
| Solis S6-EH3P75-150K INI-FAULT | Solis S6-EH3P(75-150)K10-NV-YD-H-US | AD zero drift overlink | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K OV-BUS-H | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Battery overvoltage hardware failure / VBUS | has_event_class c5 drafted · lead |
| Solis S6-EH3P75-150K OV-DC02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | DC 2 input overvoltage | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K OV-DCA-I | Solis S6-EH3P(75-150)K10-NV-YD-H-US | DC 1 average overcurrent | has_event_class c8 verified · fact |
| Solis S6-EH3P75-150K OV-DCB-I | Solis S6-EH3P(75-150)K10-NV-YD-H-US | DC 2 average overcurrent | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K OV-G-F01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid frequency exceeds the upper frequency range | has_event_class c3 verified · fact |
| Solis S6-EH3P75-150K OV-G-F02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid frequency exceeds the upper frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K OV-G-V01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage exceeds the upper voltage range | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K OV-G-V02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid transient overvoltage | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K OV-G-V03 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid transient overvoltage | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K OV-G-V04 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage exceeds the upper voltage range | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K OV-G-V05 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage RMS instanta-neous overvoltage fault | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K OV-TEM | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Module over temperature | has_event_class c10 drafted · lead |
| Solis S6-EH3P75-150K PV ISO-PRO01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | PV negative ground fault | has_event_class c8 drafted · lead |
| Solis S6-EH3P75-150K PV ISO-PRO02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | PV positive ground fault | has_event_class c8 drafted · lead |
| Solis S6-EH3P75-150K RelayChk-Fail | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Relay failure | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K Surge Alarm | Solis S6-EH3P(75-150)K10-NV-YD-H-US | On-site grid surge | has_event_class c4 drafted · lead |
| Solis S6-EH3P75-150K UNB-BUS | Solis S6-EH3P(75-150)K10-NV-YD-H-US | DC bus unbalanced voltage | has_event_class c4 drafted · lead |
| Solis S6-EH3P75-150K UN-BUS01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | DC bus undervoltage | has_event_class c4 drafted · lead |
| Solis S6-EH3P75-150K UN-BUS02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Abnormal detection of DC bus voltage | has_event_class c4 verified · fact |
| Solis S6-EH3P75-150K UN-G-F01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid frequency exceeds the lower frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K UN-G-F02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid frequency exceeds the lower frequency range | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K UN-G-V01 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage exceeds the lower voltage range | has_event_class c6 drafted · lead |
| Solis S6-EH3P75-150K UN-G-V02 | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Grid voltage exceeds the lower voltage range | has_event_class c3 drafted · lead |
| Solis S6-EH3P75-150K UN-TEM | Solis S6-EH3P(75-150)K10-NV-YD-H-US | Low temperature protection | has_event_class c6 drafted · lead |
| Solis S6-GC AFCI-Check | Solis S6-GC(25-60)K-US | AFCI self check protect ion | has_event_class c7 drafted · lead |
| Solis S6-GC BoostFal | Solis S6-GC(25-60)K-US | DC Boost converter fault | has_event_class c6 drafted · lead |
| Solis S6-GC DCInj-Fault | Solis S6-GC(25-60)K-US | Excessive DC component | has_event_class c7 verified · fact |
| Solis S6-GC DRM LINK Fail | Solis S6-GC(25-60)K-US | DRM link failed | has_event_class c5 drafted · lead |
| Solis S6-GC DSP-B-Fault | Solis S6-GC(25-60)K-US | DSP-B internal protect ion | has_event_class c6 drafted · lead |
| Solis S6-GC DSP-SelfCheck | Solis S6-GC(25-60)K-US | DSP self-check is abnormal | has_event_class c6 drafted · lead |
| Solis S6-GC IG-AD | Solis S6-GC(25-60)K-US | Abnormal grid current sampling | has_event_class c7 drafted · lead |
| Solis S6-GC IGBT-OV-I | Solis S6-GC(25-60)K-US | IGBT overcurrent | has_event_class c8 drafted · lead |
| Solis S6-GC ILeak-Check | Solis S6-GC(25-60)K-US | Leakage current self check protect ion | has_event_class c8 drafted · lead |
| Solis S6-GC ILeak-PRO | Solis S6-GC(25-60)K-US | Leakage current protect ion | has_event_class c8 drafted · lead |
| Solis S6-GC INI-FAULT | Solis S6-GC(25-60)K-US | Initialization Protect ion | has_event_class c7 drafted · lead |
| Solis S6-GC OV-DCA-I | Solis S6-GC(25-60)K-US | DC1 average overcurrent | has_event_class c8 drafted · lead |
| Solis S6-GC OV-DCB-I | Solis S6-GC(25-60)K-US | DC1 average overcurrent | has_event_class c6 drafted · lead |
| Solis S6-GC OV-IgTr | Solis S6-GC(25-60)K-US | Grid current transient overcurrent | has_event_class c6 drafted · lead |
| Solis S6-GC OV-TEM | Solis S6-GC(25-60)K-US | Temperature Protect ion | has_event_class c11 drafted · lead |
| Solis S6-GC PHASE FAULT | Solis S6-GC(25-60)K-US | Abnormal phase of the grid | has_event_class c6 drafted · lead |
| Solis S6-GC PID Repairing | Solis S6-GC(25-60)K-US | Inverter logic fault | has_event_class c8 drafted · lead |
| Solis S6-GC PV ISO-PRO 01/02 | Solis S6-GC(25-60)K-US | Ground Protect ion | has_event_class c11 drafted · lead |
| Solis S6-GC RelayChk-Fail | Solis S6-GC(25-60)K-US | Relay detection fai lure | has_event_class c6 drafted · lead |
| Solis S6-GC UN-BUS | Solis S6-GC(25-60)K-US | DC BUS voltage is too low | has_event_class c8 drafted · lead |
| Solis S6-GC UN-TEM | Solis S6-GC(25-60)K-US | Under temperature protect ion | has_event_class c6 drafted · lead |
| Solis S6-GU AFCI-Check | Solis S6-GU(250-350)K-EHV-US | AFCI self check protect ion | has_event_class c7 drafted · lead |
| Solis S6-GU BoostFal | Solis S6-GU(250-350)K-EHV-US | DC Boost converter fault | has_event_class c6 drafted · lead |
| Solis S6-GU DCInj-Fault | Solis S6-GU(250-350)K-EHV-US | Excessive DC component | has_event_class c7 drafted · lead |
| Solis S6-GU DRM LINK Fail | Solis S6-GU(250-350)K-EHV-US | DRM link failed | has_event_class c5 drafted · lead |
| Solis S6-GU DSP-B-Fault | Solis S6-GU(250-350)K-EHV-US | DSP-B internal protect ion | has_event_class c6 drafted · lead |
| Solis S6-GU DSP-SelfCheck | Solis S6-GU(250-350)K-EHV-US | DSP self-check is abnormal | has_event_class c6 drafted · lead |
| Solis S6-GU IG-AD | Solis S6-GU(250-350)K-EHV-US | Abnormal grid current sampling | has_event_class c7 drafted · lead |
| Solis S6-GU IGBT-OV-I | Solis S6-GU(250-350)K-EHV-US | IGBT overcurrent | has_event_class c8 drafted · lead |
| Solis S6-GU ILeak-Check | Solis S6-GU(250-350)K-EHV-US | Leakage current self check protect ion | has_event_class c8 drafted · lead |
| Solis S6-GU ILeak-PRO | Solis S6-GU(250-350)K-EHV-US | Leakage current protect ion | has_event_class c8 drafted · lead |
| Solis S6-GU INI-FAULT | Solis S6-GU(250-350)K-EHV-US | Initialization Protect ion | has_event_class c6 drafted · lead |
| Solis S6-GU OV-DCA-I | Solis S6-GU(250-350)K-EHV-US | DC1 average overcurrent | has_event_class c8 drafted · lead |
| Solis S6-GU OV-DCB-I | Solis S6-GU(250-350)K-EHV-US | DC1 average overcurrent | has_event_class c6 drafted · lead |
| Solis S6-GU OV-IgTr | Solis S6-GU(250-350)K-EHV-US | Grid current transient overcurrent | has_event_class c6 drafted · lead |
| Solis S6-GU OV-TEM | Solis S6-GU(250-350)K-EHV-US | Temperature Protect ion | has_event_class c10 drafted · lead |
| Solis S6-GU PHASE FAULT | Solis S6-GU(250-350)K-EHV-US | Abnormal phase of the grid | has_event_class c6 drafted · lead |
| Solis S6-GU PID Repairing | Solis S6-GU(250-350)K-EHV-US | Inverter logic fault | has_event_class c8 drafted · lead |
| Solis S6-GU PV ISO-PRO 01/02 | Solis S6-GU(250-350)K-EHV-US | Ground Protect ion | has_event_class c10 verified · fact |
| Solis S6-GU RelayChk-Fail | Solis S6-GU(250-350)K-EHV-US | Relay detection fai lure | has_event_class c6 drafted · lead |
| Solis S6-GU UN-BUS | Solis S6-GU(250-350)K-EHV-US | DC BUS voltage is too low | has_event_class c7 drafted · lead |
| Solis S6-GU UN-TEM | Solis S6-GU(250-350)K-EHV-US | Under temperature protect ion | has_event_class c6 drafted · lead |
Sungrow
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Sungrow SG-CX-US 010 | Sungrow SG36/60CX-US | Grid power outage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 105 | Sungrow SG36/60CX-US | Protection self-check failure on grid side | has_event_class c5 drafted · lead |
| Sungrow SG-CX-US 106 | Sungrow SG36/60CX-US | Grounding cable fault | has_event_class c7 drafted · lead |
| Sungrow SG-CX-US 011 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 012 | Sungrow SG36/60CX-US | Excessive leakage current | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 013 | Sungrow SG36/60CX-US | Grid abnormal | has_event_class c5 drafted · lead |
| Sungrow SG-CX-US 014 | Sungrow SG36/60CX-US | 10-minute grid overvoltage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 015 | Sungrow SG36/60CX-US | Grid overvoltage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 016 | Sungrow SG36/60CX-US | Output overload | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 017 | Sungrow SG36/60CX-US | Grid voltage unbalance | has_event_class c8 verified · fact |
| Sungrow SG-CX-US 019-020 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 verified · fact |
| Sungrow SG-CX-US 002 | Sungrow SG36/60CX-US | Grid overvoltage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 021-022 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 024-025 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 003 | Sungrow SG36/60CX-US | Grid transient overvoltage | has_event_class c4 verified · fact |
| Sungrow SG-CX-US 030-034 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 036 | Sungrow SG36/60CX-US | Temperature anomaly | has_event_class c4 verified · fact |
| Sungrow SG-CX-US 037 | Sungrow SG36/60CX-US | Temperature anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 038 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 039 | Sungrow SG36/60CX-US | Low system insulation resistance | has_event_class c5 drafted · lead |
| Sungrow SG-CX-US 004 | Sungrow SG36/60CX-US | Grid undervoltage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 040-042 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 043 | Sungrow SG36/60CX-US | Low ambient temperature | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 044-046 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 448-471 | Sungrow SG36/60CX-US | String x reverse connection fault | has_event_class c7 drafted · lead |
| Sungrow SG-CX-US 047 | Sungrow SG36/60CX-US | PV input configuration abnormal | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 048-050 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 005 | Sungrow SG36/60CX-US | Grid low voltage | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 053-056 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 059-060 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 007 | Sungrow SG36/60CX-US | AC instantaneous overcurrent | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 076 | Sungrow SG36/60CX-US | Device anomaly | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 008 | Sungrow SG36/60CX-US | Grid overfrequency | has_event_class c4 drafted · lead |
| Sungrow SG-CX-US 088 | Sungrow SG36/60CX-US | Electric arc fault | has_event_class c8 drafted · lead |
| Sungrow SG-CX-US 009 | Sungrow SG36/60CX-US | Grid underfrequency | has_event_class c4 drafted · lead |
| Sungrow SG200HX 010 | Sungrow SG200HX-US | Grid Power Outage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 100-105 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 106 | Sungrow SG200HX-US | Grounding Cable Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 107-114 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 1096-1122 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 011 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 116-124 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 012 | Sungrow SG200HX-US | Excess Leakage Current | has_event_class c3 drafted · lead |
| Sungrow SG200HX 1200-1295 | Sungrow SG200HX-US | Electric Arc Fault | has_event_class c8 drafted · lead |
| Sungrow SG200HX 013 | Sungrow SG200HX-US | Grid Abnormal | has_event_class c4 drafted · lead |
| Sungrow SG200HX 014 | Sungrow SG200HX-US | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 015 | Sungrow SG200HX-US | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 016 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 1600-1615 | Sungrow SG200HX-US | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 1616 | Sungrow SG200HX-US | System Hardware Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 1632-1655 | Sungrow SG200HX-US | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 19-25 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 002 | Sungrow SG200HX-US | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 200-211 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 208 | Sungrow SG200HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 212 | Sungrow SG200HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 248-255 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 28 | Sungrow SG200HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 29 | Sungrow SG200HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 003 | Sungrow SG200HX-US | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 030-034 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 300-322 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 324-328 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 036 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 364-395 | Sungrow SG200HX-US | Boost Capacitor Overvoltage Fault | has_event_class c3 verified · fact |
| Sungrow SG200HX 037 | Sungrow SG200HX-US | Excessively High Ambient Temperature | has_event_class c3 drafted · lead |
| Sungrow SG200HX 038 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 039 | Sungrow SG200HX-US | Low System Insulation Resistance | has_event_class c4 drafted · lead |
| Sungrow SG200HX 004 | Sungrow SG200HX-US | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 040-042 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 401-412 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 043 | Sungrow SG200HX-US | Excessively Low Ambient Temperature | has_event_class c3 drafted · lead |
| Sungrow SG200HX 44-50 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 448-479 | Sungrow SG200HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG200HX 005 | Sungrow SG200HX-US | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG200HX 52-58 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 60-69 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 600-603 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 605 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 608 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 612 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 616 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 620 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 622-624 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 007 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 008 | Sungrow SG200HX-US | Grid Overfrequency | has_event_class c3 drafted · lead |
| Sungrow SG200HX 800 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 802 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 804 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 807 | Sungrow SG200HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG200HX 85 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 009 | Sungrow SG200HX-US | Grid Underfrequency | has_event_class c3 drafted · lead |
| Sungrow SG200HX 92 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG200HX 93 | Sungrow SG200HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 10 | Sungrow SG250HX | Grid Power Outage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 100-105 | Sungrow SG250HX | System Fault | has_event_class c2 verified · fact |
| Sungrow SG250HX 107-114 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 1096-1122 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 11 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 116-124 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 12 | Sungrow SG250HX | Excess Leakage Current | has_event_class c3 verified · fact |
| Sungrow SG250HX 13 | Sungrow SG250HX | Grid Abnormal | has_event_class c4 drafted · lead |
| Sungrow SG250HX 14 | Sungrow SG250HX | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 15 | Sungrow SG250HX | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 16 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 1600-1615 | Sungrow SG250HX | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 1616 | Sungrow SG250HX | System Hardware Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 1632-1655 | Sungrow SG250HX | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 17 | Sungrow SG250HX | Grid Voltage Imbalance | has_event_class c3 drafted · lead |
| Sungrow SG250HX 19-25 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 2 | Sungrow SG250HX | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 200-211 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 208 | Sungrow SG250HX | PV Reserve Con-nection Fault | has_event_class c6 drafted · lead |
| Sungrow SG250HX 212 | Sungrow SG250HX | PV Reserve Con-nection Fault | has_event_class c6 drafted · lead |
| Sungrow SG250HX 248-255 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 264-283 | Sungrow SG250HX | MPPT Reverse Connection | has_event_class c2 drafted · lead |
| Sungrow SG250HX 28 | Sungrow SG250HX | PV Reserve Con-nection Fault | has_event_class c6 drafted · lead |
| Sungrow SG250HX 29 | Sungrow SG250HX | PV Reserve Con-nection Fault | has_event_class c6 drafted · lead |
| Sungrow SG250HX 3 | Sungrow SG250HX | Grid Overvoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 30-34 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 300-322 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 324-328 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 36 | Sungrow SG250HX | System Fault | has_event_class c7 drafted · lead |
| Sungrow SG250HX 364-395 | Sungrow SG250HX | Boost Capacitor Overvoltage Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 37 | Sungrow SG250HX | Excessively High Ambient Temperature | has_event_class c8 drafted · lead |
| Sungrow SG250HX 38 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 4 | Sungrow SG250HX | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 40-42 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 401-412 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 43 | Sungrow SG250HX | Excessively Low Ambient Temperature | has_event_class c3 drafted · lead |
| Sungrow SG250HX 44-50 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 448-479 | Sungrow SG250HX | PV Reserve Con-nection Fault | has_event_class c6 drafted · lead |
| Sungrow SG250HX 5 | Sungrow SG250HX | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG250HX 52-58 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 60-69 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 600-603 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 605 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 608 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 612 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 616 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 620 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 622-624 | Sungrow SG250HX | System Fault | has_event_class c4 drafted · lead |
| Sungrow SG250HX 7 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 8 | Sungrow SG250HX | Grid Overfrequency | has_event_class c3 drafted · lead |
| Sungrow SG250HX 800 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 802 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 804 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 807 | Sungrow SG250HX | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG250HX 85 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 88 | Sungrow SG250HX | Electric Arc Fault | has_event_class c8 drafted · lead |
| Sungrow SG250HX 9 | Sungrow SG250HX | Grid Underfrequency | has_event_class c3 drafted · lead |
| Sungrow SG250HX 92 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG250HX 93 | Sungrow SG250HX | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 010 | Sungrow SG350HX-US | Grid Power Outage | has_event_class c3 drafted · lead |
| Sungrow SG350HX 100-105 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 106 | Sungrow SG350HX-US | Grounding Cable Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 107-114 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 1096-1122 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 011 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 116-124 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 012 | Sungrow SG350HX-US | Excess Leakage Current | has_event_class c3 drafted · lead |
| Sungrow SG350HX 013 | Sungrow SG350HX-US | Grid Abnormal | has_event_class c4 drafted · lead |
| Sungrow SG350HX 014 | Sungrow SG350HX-US | Grid Overvoltage | has_event_class c3 verified · fact |
| Sungrow SG350HX 015 | Sungrow SG350HX-US | Grid Overvoltage | has_event_class c3 verified · fact |
| Sungrow SG350HX 016 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 1600-1615 | Sungrow SG350HX-US | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 1616 | Sungrow SG350HX-US | System Hardware Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 1632-1655 | Sungrow SG350HX-US | PV Grounding Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 19-25 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 002 | Sungrow SG350HX-US | Grid Overvoltage | has_event_class c3 verified · fact |
| Sungrow SG350HX 200-211 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 208 | Sungrow SG350HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 212 | Sungrow SG350HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 248-255 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 28 | Sungrow SG350HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 29 | Sungrow SG350HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 003 | Sungrow SG350HX-US | Grid Overvoltage | has_event_class c3 verified · fact |
| Sungrow SG350HX 030-034 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 300-322 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 324-328 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 036 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 364-395 | Sungrow SG350HX-US | Boost Capacitor Overvoltage Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 037 | Sungrow SG350HX-US | Excessively High Ambient Temperature | has_event_class c3 drafted · lead |
| Sungrow SG350HX 038 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 039 | Sungrow SG350HX-US | Low System Insulation Resistance | has_event_class c4 drafted · lead |
| Sungrow SG350HX 004 | Sungrow SG350HX-US | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG350HX 040-042 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 401-412 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 043 | Sungrow SG350HX-US | Excessively Low Ambient Temperature | has_event_class c3 drafted · lead |
| Sungrow SG350HX 44-50 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 448-479 | Sungrow SG350HX-US | PV Reserve Connection Fault | has_event_class c6 drafted · lead |
| Sungrow SG350HX 005 | Sungrow SG350HX-US | Grid Undervoltage | has_event_class c3 drafted · lead |
| Sungrow SG350HX 52-58 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 60-69 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 600-603 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 605 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 608 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 612 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 616 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 620 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 622-624 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 007 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 008 | Sungrow SG350HX-US | Grid Overfrequency | has_event_class c3 drafted · lead |
| Sungrow SG350HX 800 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 802 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 804 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 807 | Sungrow SG350HX-US | System Fault | has_event_class c2 drafted · lead |
| Sungrow SG350HX 85 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 009 | Sungrow SG350HX-US | Grid Underfrequency | has_event_class c3 verified · fact |
| Sungrow SG350HX 92 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
| Sungrow SG350HX 93 | Sungrow SG350HX-US | System Fault | has_event_class c3 drafted · lead |
Yaskawa Solectria
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Yaskawa Solectria PVI-14-20TL Arc Protect | Solectria PVI 14/20TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-14-20TL GFCI.Err | Solectria PVI 14/20TL | DC leakage current is above recommend value | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL GridF.OutLim | Solectria PVI 14/20TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-14-20TL GridV.OutLim | Solectria PVI 14/20TL | Grid voltage exceeds the specified range | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL IntFaultA~O | Solectria PVI 14/20TL | Internal noncritical fault within the inverter | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL IntProtectA~Z | Solectria PVI 14/20TL | Internal problem within the inverter | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL OverTemp | Solectria PVI 14/20TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-14-20TL PV1 (2) Reverse | Solectria PVI 14/20TL | DC inputs connected with incorrect polarities | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL PV1 (2) VoltOver | Solectria PVI 14/20TL | DC input voltage exceeds the specified value | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0100 | Solectria PVI 20/25TL-480-R | Grid relay fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0110 | Solectria PVI 20/25TL-480-R | Bus imbalance | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0130 | Solectria PVI 20/25TL-480-R | Bus over total voltage | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0150 | Solectria PVI 20/25TL-480-R | Open-loop self-check failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0020 | Solectria PVI 20/25TL-480-R | Bus over volt Hardware | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0060 | Solectria PVI 20/25TL-480-R | CPLD Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Fault0090 | Solectria PVI 20/25TL-480-R | Static leakage current high | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0100 | Solectria PVI 20/25TL-480-R | The sensor fault of leakage current | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0110 | Solectria PVI 20/25TL-480-R | BUS over voltage (firmware) | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0150 | Solectria PVI 20/25TL-480-R | Mini MCU Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0170 | Solectria PVI 20/25TL-480-R | DCI high | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0180 | Solectria PVI 20/25TL-480-R | The sampling offset of DCI | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0020 | Solectria PVI 20/25TL-480-R | Grid relay error | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0230 | Solectria PVI 20/25TL-480-R | Inverter open-loop self-test fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0030 | Solectria PVI 20/25TL-480-R | Inverter Over Current | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Protect0070 | Solectria PVI 20/25TL-480-R | Bus imbalance | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R TempOver | Solectria PVI 20/25TL-480-R | Over-temperature protection | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL Arc Board Error | Solectria PVI 23/28/36TL | Internal Arc board self-check error | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL Arc Protect | Solectria PVI 23/28/36TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-TL GFCI.Err | Solectria PVI 23/28/36TL | DC leakage current is above recommended value | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL GridF.OutLim | Solectria PVI 23/28/36TL | Grid voltage frequency is abnormal | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL GridV.OutLim | Solectria PVI 23/28/36TL | Grid voltage exceeds the specified range | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL IntFault0010-150 | Solectria PVI 23/28/36TL | Internal non-critical fault within the inverter | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL IntProtect0010-0260 | Solectria PVI 23/28/36TL | Internal problem within the inverter | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL IsolationErr | Solectria PVI 23/28/36TL | DC insulation impedance to ground | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL OverTemp | Solectria PVI 23/28/36TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-TL PV1 (2) Reverse | Solectria PVI 23/28/36TL | DC inputs connected with incorrect polarities | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL PV1 (2) VoltOver | Solectria PVI 23/28/36TL | DC input voltage exceeds the specified value | has_event_class c2 drafted · lead |
| Yaskawa Solectria SGI-XTM Contactor Fail | Solectria SGI 500/750XTM | has_event_class c4 drafted · lead | |
| Yaskawa Solectria SGI-XTM CT Failure | Solectria SGI 500/750XTM | has_event_class c4 drafted · lead | |
| Yaskawa Solectria SGI-XTM DC GND Fault | Solectria SGI 500/750XTM | has_event_class c4 drafted · lead | |
| Yaskawa Solectria SGI-XTM Desat Error | Solectria SGI 500/750XTM | has_event_class c3 drafted · lead | |
| Yaskawa Solectria SGI-XTM IGBT Overtemp | Solectria SGI 500/750XTM | has_event_class c3 drafted · lead | |
| Yaskawa Solectria SGI-XTM NTC Failure | Solectria SGI 500/750XTM | has_event_class c4 drafted · lead | |
| Yaskawa Solectria SGI-XTM Open Phase | Solectria SGI 500/750XTM | has_event_class c3 drafted · lead | |
| Yaskawa Solectria SGI-XTM RCM Fault | Solectria SGI 500/750XTM | has_event_class c3 drafted · lead | |
| Yaskawa Solectria SGI-XTM Shunt Trip | Solectria SGI 500/750XTM | has_event_class c2 drafted · lead | |
| Yaskawa Solectria SGI-XTM Vsense Error | Solectria SGI 500/750XTM | has_event_class c2 drafted · lead | |
| Yaskawa Solectria XGI-1500-1MW CRIT-1 | Yaskawa Solectria XGI 1500-1MW | Software Parameter Load Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-11 | Yaskawa Solectria XGI 1500-1MW | Operational Self Check Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-12 | Yaskawa Solectria XGI 1500-1MW | Startup Self Check Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-2 | Yaskawa Solectria XGI 1500-1MW | Internal Communication 1 Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-3 | Yaskawa Solectria XGI 1500-1MW | Internal Communication 2 Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-32 | Yaskawa Solectria XGI 1500-1MW | has_event_class c2 drafted · lead | |
| Yaskawa Solectria XGI-1500-1MW CRIT-5 | Yaskawa Solectria XGI 1500-1MW | AC Contactor Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-6 | Yaskawa Solectria XGI 1500-1MW | Critical Over Temperature | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-7 | Yaskawa Solectria XGI 1500-1MW | Ground Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW CRIT-9 | Yaskawa Solectria XGI 1500-1MW | Critical Internal Hardware Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-1 | Yaskawa Solectria XGI 1500 | Software Parameter Load Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-10 | Yaskawa Solectria XGI 1500 | Ground Fault Detection Self Check Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-11 | Yaskawa Solectria XGI 1500 | Operational Self Check Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-12 | Yaskawa Solectria XGI 1500 | Startup Self Check Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-2 | Yaskawa Solectria XGI 1500 | Internal Communication 1 Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-3 | Yaskawa Solectria XGI 1500 | Internal Communication 2 Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-32 | Yaskawa Solectria XGI 1500 | has_event_class c4 drafted · lead | |
| Yaskawa Solectria XGI-1500 CRIT-4 | Yaskawa Solectria XGI 1500 | ARC Fault Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-5 | Yaskawa Solectria XGI 1500 | AC Contactor Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-6 | Yaskawa Solectria XGI 1500 | Critical Over Temperature | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-7 | Yaskawa Solectria XGI 1500 | Ground Fault, Excessive Leakage Current | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-8 | Yaskawa Solectria XGI 1500 | Ground Fault, Isolation Resistance Low | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 CRIT-9 | Yaskawa Solectria XGI 1500 | Critical Internal Hardware Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-1 | Yaskawa Solectria XGI 1500-DCG | Software Parameter Load Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-11 | Yaskawa Solectria XGI 1500-DCG | Operational Self Check Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-12 | Yaskawa Solectria XGI 1500-DCG | Startup Self Check Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-2 | Yaskawa Solectria XGI 1500-DCG | Internal Communication 1 Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-3 | Yaskawa Solectria XGI 1500-DCG | Internal Communication 2 Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-32 | Yaskawa Solectria XGI 1500-DCG | Reserved | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-5 | Yaskawa Solectria XGI 1500-DCG | AC Contactor Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-6 | Yaskawa Solectria XGI 1500-DCG | Critical Over Temperature | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-7 | Yaskawa Solectria XGI 1500-DCG | Ground Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG CRIT-9 | Yaskawa Solectria XGI 1500-DCG | Critical Internal Hardware Failure | has_event_class c2 drafted · lead |