Solar Lattice

Fault codes › Huawei › Huawei SUN2000-45KTL-US-HV-D0

Huawei SUN2000-45KTL-US-HV-D0 202

Code
202
Shown as
Abnormal Invert Circuit
Vendor severity
Major
Page
115
ID
fc:huawei-sun2000-45ktl-us-hv-d0-202
IRI
https://solarlattice.org/kb/fc/huawei-sun2000-45ktl-us-hv-d0-202
Status
active
Also known as
202, Huawei 202, Abnormal Invert Circuit
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports AC overcurrent, high DC injection; look at inverter bridge, AC cable; do: AC connection check, contact manufacturer service.

What can be behind AC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

What can be behind High DC injection

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E023, ABB / FIMER PVS-166-175-TL E006, ABB / FIMER PVS-60-TL E023, ABB / FIMER PVS-60-TL E006, ABB / FIMER TRIO-20.0-27.6-TL E023, ABB / FIMER TRIO-20.0-27.6-TL E006, ABB / FIMER UNO-DM-3.3-5.0-PLUS E023, ABB / FIMER UNO-DM-3.3-5.0-PLUS E006, ABB / FIMER UNO-DM-6.0-PLUS E023, ABB / FIMER UNO-DM-6.0-PLUS E006
CPS
CPS SCA25KTL-208 Protect0170, CPS SCA25KTL-480 Protect0170, CPS SCA36KTL Protect0170, CPS SCA50-100K-T Protect1110, CPS SCA50-100K-T Protect0170, CPS SCA50-60KTL Protect0170, CPS SCH100-125KTL Protect0170, CPS SCH125KTL-AIO Protect0170, CPS SCH200-250K-T Protect0170, CPS SCH275KTL Protect0170, CPS SCH350KTL Protect0170
Canadian Solar
Canadian Solar 185-255K DCinj-FAULT, Canadian Solar 185-255K OV-G-I
Fronius
Fronius Galvo 301, Fronius Galvo 408, Fronius Primo 301, Fronius Primo 408, Fronius Symo 301, Fronius Symo 408
Huawei
Huawei SUN2000-100KTL-USH0 2039, Huawei SUN2000-100KTL-USH0 2040, Huawei SUN2000-25-30KTL-US 202
KACO new energy
KACO new energy blueplanet TL3 33, KACO new energy blueplanet TL3 36, KACO new energy blueplanet TL3 87, KACO new energy blueplanet TL3 88, KACO new energy blueplanet TL3 89
SMA
SMA SB-US-40 601, SMA SB-US-41 601, SMA SBSE-US-50 601, SMA PEAK3-US 601, SMA CORE1-US 601, SMA STP-TL-US 601, SMA STP-X-US 601, SMA STP-X-US 6404, SMA SC-CP-XT 6404, SMA SI-US F117, SMA SI-US W118, SMA SI-US W119, SMA SI-US W120, SMA SI-US W377, SMA SI-US W378, SMA SI-US W379, SMA SI-US W380, SMA SI-US W505, SMA SI-US W506, SMA SI-US W507, SMA SI-US W508
Schneider Electric
Schneider Electric CL125 011, Schneider Electric CL125 040, Schneider Electric CL125 006, Schneider Electric CL125 007
Solis
Solis 1P-4G-US GRID-INTF, Solis 3P-5G-US DCInj-Fault, Solis 3P-5G-US OV-G-I, Solis RHI-1P-HV DCInj-Fault, Solis RHI-1P-HV OV-G-I, Solis RHI-1P-HV OV-IgTr, Solis S5-GC GRID-INTF, Solis S6-EH1P DCInj-Fault, Solis S6-EH1P OV-G-I, Solis S6-EH1P OV-IgTr, Solis S6-EH2P DCInj-Fault, Solis S6-EH2P GRID-INTF, Solis S6-EH2P OV-G-I, Solis S6-EH3P30-60K DCInj-Fault, Solis S6-EH3P30-60K GRID-INTF, Solis S6-EH3P30-60K OV-G-I, Solis S6-EH3P75-150K DCInj-Fault, Solis S6-EH3P75-150K GRID-INTF, Solis S6-EH3P75-150K OV-G-I, Solis S6-GC DCInj-Fault, Solis S6-GC GRID-INTF, Solis S6-GC OV-G-I, Solis S6-GC OV-IgTr, Solis S6-GU DCInj-Fault, Solis S6-GU GRID-INTF, Solis S6-GU OV-G-I, Solis S6-GU OV-IgTr
Sungrow
Sungrow SG-CX-US 007, Sungrow SG200HX 007, Sungrow SG250HX 7, Sungrow SG350HX 007
Yaskawa Solectria
Yaskawa Solectria PVI-25TL-R Protect0170

Same code in other families

Claims

defined_in

c1 drafted · lead Huawei SUN2000-45KTL-US-HV-D0 User Manual

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the Type column

reports

c3 drafted · lead AC overcurrent

review note: support check: partial - Instantaneous high output current and output short-circuit surge are stated, though the alarm is named an invert module fault.

c4 drafted · lead High DC injection

Cause 16

affects

c5 drafted · lead Inverter bridge

c6 drafted · lead AC cable

Output short circuit, cause 20

mitigated_by

c7 drafted · lead AC connection check

review note: support check: partial - Only checking output cables for short circuits is stated, not a broader AC connection check.

c8 drafted · lead Contact manufacturer service

If the alarm persists

has_production_effect

c9 drafted · lead Trip (production stops)

has_recovery

c10 drafted · lead Auto-reset (clears by itself)

For grid-caused causes 13/14/16; escalate to service if it persists

applies_to

c11 drafted · lead Huawei SUN2000-45KTL-US-HV-D0

Data