Solar Lattice

Fault codes › KACO new energy › KACO blueplanet 87.0-165 TL3

KACO new energy blueplanet TL3 87

Code
87
Shown as
Protection shutdown over-current L1
Page
106
ID
fc:kaco-blueplanet-87-165-tl3-87
IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-87
Status
active
Also known as
87, KACO new energy 87, Protection shutdown over-current L1
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports AC overcurrent; do: contact system installer.

What can be behind AC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E006, ABB / FIMER PVS-60-TL E006, ABB / FIMER TRIO-20.0-27.6-TL E006, ABB / FIMER UNO-DM-3.3-5.0-PLUS E006, ABB / FIMER UNO-DM-6.0-PLUS E006
CPS
CPS SCA50-100K-T Protect1110
Canadian Solar
Canadian Solar 185-255K OV-G-I
Fronius
Fronius Galvo 301, Fronius Primo 301, Fronius Symo 301
Huawei
Huawei SUN2000-100KTL-USH0 2039, Huawei SUN2000-25-30KTL-US 202, Huawei SUN2000-45KTL-US-HV-D0 202
KACO new energy
KACO new energy blueplanet TL3 36, KACO new energy blueplanet TL3 88, KACO new energy blueplanet TL3 89
SMA
SMA STP-X-US 6404, SMA SC-CP-XT 6404, SMA SI-US F117, SMA SI-US W118, SMA SI-US W119, SMA SI-US W120, SMA SI-US W377, SMA SI-US W378, SMA SI-US W379, SMA SI-US W380, SMA SI-US W505, SMA SI-US W506, SMA SI-US W507, SMA SI-US W508
Schneider Electric
Schneider Electric CL125 040, Schneider Electric CL125 006, Schneider Electric CL125 007
Solis
Solis 1P-4G-US GRID-INTF, Solis 3P-5G-US OV-G-I, Solis RHI-1P-HV OV-G-I, Solis RHI-1P-HV OV-IgTr, Solis S5-GC GRID-INTF, Solis S6-EH1P OV-G-I, Solis S6-EH1P OV-IgTr, Solis S6-EH2P GRID-INTF, Solis S6-EH2P OV-G-I, Solis S6-EH3P30-60K GRID-INTF, Solis S6-EH3P30-60K OV-G-I, Solis S6-EH3P75-150K GRID-INTF, Solis S6-EH3P75-150K OV-G-I, Solis S6-GC GRID-INTF, Solis S6-GC OV-G-I, Solis S6-GC OV-IgTr, Solis S6-GU GRID-INTF, Solis S6-GU OV-G-I, Solis S6-GU OV-IgTr
Sungrow
Sungrow SG-CX-US 007, Sungrow SG200HX 007, Sungrow SG250HX 7, Sungrow SG350HX 007

Claims

defined_in

c1 drafted · lead KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)

reports

c2 verified · fact AC overcurrent

verified by: review-workflowverified on: 2026-10-23

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

has_production_effect

c4 drafted · lead Trip (production stops)

mitigated_by

c5 drafted · lead Contact system installer

Only on repeated occurrence.

applies_to

c6 drafted · lead KACO blueplanet 87.0-165 TL3

Data