Fault codes › Sungrow › Sungrow SG350HX-US

Sungrow SG350HX 007

Code
007
Shown as
System Fault
Page
92
ID
fc:sungrow-sg350hx-7
IRI
https://solarlattice.org/kb/fc/sungrow-sg350hx-7
Status
active
Also known as
007, 7, Sungrow 007, System Fault
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports AC overcurrent; do: inverter restart.

What can be behind AC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E006, ABB / FIMER PVS-60-TL E006, ABB / FIMER TRIO-20.0-27.6-TL E006, ABB / FIMER UNO-DM-3.3-5.0-PLUS E006, ABB / FIMER UNO-DM-6.0-PLUS E006
CPS
CPS SCA50-100K-T Protect1110
Canadian Solar
Canadian Solar 185-255K OV-G-I
Fronius
Fronius Galvo 301, Fronius Primo 301, Fronius Symo 301
Huawei
Huawei SUN2000-100KTL-USH0 2039, Huawei SUN2000-25-30KTL-US 202, Huawei SUN2000-45KTL-US-HV-D0 202
KACO new energy
KACO new energy blueplanet TL3 36, KACO new energy blueplanet TL3 87, KACO new energy blueplanet TL3 88, KACO new energy blueplanet TL3 89
SMA
SMA STP-X-US 6404, SMA SC-CP-XT 6404, SMA SI-US F117, SMA SI-US W118, SMA SI-US W119, SMA SI-US W120, SMA SI-US W377, SMA SI-US W378, SMA SI-US W379, SMA SI-US W380, SMA SI-US W505, SMA SI-US W506, SMA SI-US W507, SMA SI-US W508
Schneider Electric
Schneider Electric CL125 040, Schneider Electric CL125 006, Schneider Electric CL125 007
Solis
Solis 1P-4G-US GRID-INTF, Solis 3P-5G-US OV-G-I, Solis RHI-1P-HV OV-G-I, Solis RHI-1P-HV OV-IgTr, Solis S5-GC GRID-INTF, Solis S6-EH1P OV-G-I, Solis S6-EH1P OV-IgTr, Solis S6-EH2P GRID-INTF, Solis S6-EH2P OV-G-I, Solis S6-EH3P30-60K GRID-INTF, Solis S6-EH3P30-60K OV-G-I, Solis S6-EH3P75-150K GRID-INTF, Solis S6-EH3P75-150K OV-G-I, Solis S6-GC GRID-INTF, Solis S6-GC OV-G-I, Solis S6-GC OV-IgTr, Solis S6-GU GRID-INTF, Solis S6-GU OV-G-I, Solis S6-GU OV-IgTr
Sungrow
Sungrow SG-CX-US 007, Sungrow SG200HX 007, Sungrow SG250HX 7

Same code in other families

Claims

defined_in

c1 drafted · lead Sungrow SG350HX-US User Manual

reports

c2 drafted · lead AC overcurrent

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

has_production_effect

c4 drafted · lead Trip (production stops)

review note: support check: partial - Reconnection implies disconnection, but production stop is not explicit.

has_recovery

c5 drafted · lead Auto-reset (clears by itself)

Escalation: wait, then power-cycle restart, then contact service.

review note: support check: partial - Reconnection after grid normal and the wait/restart/contact escalation are stated, but whether it clears automatically is mixed with manual power-cycle steps.

mitigated_by

c6 drafted · lead Inverter restart

applies_to

c7 drafted · lead Sungrow SG350HX-US