Solar Lattice

Product

Sungrow SG350HX-US

ID
prod:sungrow-sg350hx
IRI
https://solarlattice.org/kb/prod/sungrow-sg350hx
Status
active
Also known as
SG350HX, SG350HX-US
Category
Inverters
Make
sungrow
Product level
family

The Sungrow SG350HX-US is a transformerless three-phase PV inverter that connects to the grid. Its maximum efficiency is 99.02 percent and its CEC efficiency is 98.5 percent. Its maximum AC output current is 254 A. At 40 °C, full-power MPP tracking covers 860 V to 1330 V. The AC voltage range is 704 V to 880 V. Built-in protection covers DC reverse connection, AC short circuit, leakage current, ground faults and grid monitoring. It also has Type II surge protection on the DC and AC sides. The inverter has a DC switch but no AC switch. It supports PV string current monitoring and reactive power at night. Anti-PID and PID recovery are optional and need the EMU200. It communicates over RS485 and PLC, and on site you can reach it through LED indicators or Bluetooth with an app. The inverter is listed to UL 1741 including SA and SB, UL 62109-1, CSA C22.2 No.107.1, IEEE 1547-2018, IEEE 1547.1-2020, California Rule 21 and HECO SRD V2.0. It is IP66 (NEMA 4X) rated, cooled by smart forced air, and weighs up to 123 kg.

Claims

manufactured_by

c1 drafted · lead Sungrow proposed

review note: support check: partial - Passages mention SUNGROW warranty and the SG350HX-US title, but never explicitly state Sungrow manufactures this model (implied only).

instance_of

c2 drafted · lead Inverter

PV grid-connected inverter

uses_protocol

c3 drafted · lead RS-485

RS485 connection on COM1 per the quick installation guide

c4 drafted · lead Power line communication

c5 drafted · lead Bluetooth

Local display is LEDs plus Bluetooth with an app

certified_to

c6 drafted · lead UL 1741 proposed

c7 verified · fact UL 1741 SA proposed

verified by: review-workflowverified on: 2026-10-24

c8 drafted · lead UL 1741 SB proposed

c9 drafted · lead UL 62109-1 proposed

c10 drafted · lead IEEE 1547-2018 proposed

c11 drafted · lead IEEE 1547.1-2020 proposed

c12 verified · fact CA Rule 21 proposed

verified by: review-workflowverified on: 2026-10-24

c13 drafted · lead HECO SRD V2.0 proposed

implements

c14 drafted · lead Reverse polarity protection

DC reverse connection protection

c15 verified · fact Residual current monitoring

Listed as leakage current protection

verified by: review-workflowverified on: 2026-10-24

c16 drafted · lead DC ground-fault protection

Listed as ground fault monitoring

c17 verified · fact String monitoring

verified by: review-workflowverified on: 2026-10-24

c18 drafted · lead Reactive power at night

c19 drafted · lead Surge protection

Type II on both DC and AC sides

c20 verified · fact PID recovery

Optional, provided with the EMU200 accessory

verified by: review-workflowverified on: 2026-10-24

requires

c21 drafted · lead Sungrow EMU200 proposed

Needed only for the optional anti-PID and PID recovery function

review note: support check: partial - EMU200 is tied to the optional anti-PID function, but 'requires' is only implied as optional and not stated as a requirement.

efficiency

c22 drafted · lead nominal 99.02 PERCENT

Conditions: Maximum efficiency

review note: possible conflict with c23 (same source; check the conditions)

c23 drafted · lead nominal 98.5 PERCENT

Conditions: CEC weighted efficiency

review note: possible conflict with c22 (same source; check the conditions)

mppt_voltage_range

c24 drafted · lead 860–1330 V

Conditions: Full power MPP voltage range at 40 °C

rated_output_current

c25 drafted · lead nominal 254 A

Conditions: Maximum AC output current

Referenced by