Fault codes › Sungrow › Sungrow SG350HX-US
Sungrow SG350HX 013
- Code
013
- Shown as
- Grid Abnormal
- Page
- 88
- ID
fc:sungrow-sg350hx-13
- IRI
https://solarlattice.org/kb/fc/sungrow-sg350hx-13
- Status
- active
- Also known as
- 013, 13, Sungrow 013, Grid Abnormal
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports grid voltage out of range, grid frequency out of range; confirm with grid frequency measurement; do: utility company consultation.
Failure modes that present as the reported condition, and the tests that tell them apart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- CPS
- CPS SCA25KTL-208 GridF.OutLim, CPS SCA25KTL-208 GridV.OutLim, CPS SCA25KTL-480 GridF.OutLim, CPS SCA25KTL-480 GridV.OutLim, CPS SCA36KTL GridF.OutLim, CPS SCA36KTL GridV.OutLim, CPS SCA50-100K-T Protect0080, CPS SCA50-60KTL GridF.OutLim, CPS SCA50-60KTL GridV.OutLim, CPS SCH100-125KTL GridF.OutLim, CPS SCH100-125KTL GridV.OutLim, CPS SCH125KTL-AIO GridF.OutLim, CPS SCH125KTL-AIO GridV.OutLim, CPS SCH200-250K-T GridF.OutLim, CPS SCH200-250K-T GridV.OutLim, CPS SCH275KTL GridF.OutLim, CPS SCH275KTL GridV.OutLim, CPS SCH350KTL GridF.OutLim, CPS SCH350KTL GridV.OutLim
- Canadian Solar
- Canadian Solar 23-28KTL-CT GridF.OutLim, Canadian Solar 23-28KTL-CT GridV.OutLim
- Fronius
- Fronius Galvo 453, Fronius Galvo 454, Fronius Primo 453, Fronius Primo 454, Fronius Symo 453, Fronius Symo 454
- Huawei
- Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 301, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 47
- SMA
- SMA SB-US-40 501, SMA SB-US-40 701, SMA SB-US-41 0205, SMA SB-US-41 501, SMA SB-US-41 701, SMA SBSE-US-50 501, SMA SBSE-US-50 701, SMA PEAK3-US 501, SMA PEAK3-US 701, SMA CORE1-US 501, SMA STP-TL-US 501, SMA STP-TL-US 701, SMA STP-X-US 501, SMA STP-X-US 701, SMA SC-CP-XT 1500, SMA SC-CP-XT 0205, SMA SI-US W335, SMA SI-US W336, SMA SI-US W337, SMA SI-US W338, SMA SI-US W807
- Schneider Electric
- Schneider Electric CL125 013, Schneider Electric CL125 003, Schneider Electric CL125 053, Schneider Electric CL125 054
- Solis
- Solis S6-EH2P LmtByFreq, Solis S6-EH3P30-60K LmtByFreq, Solis S6-EH3P75-150K LmtByFreq, Solis S6-GC G-F-FLU, Solis S6-GU G-F-FLU
- Sungrow
- Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL GridF.OutLim, Yaskawa Solectria PVI-14-20TL GridV.OutLim, Yaskawa Solectria PVI-25TL-R GridF.OutLim, Yaskawa Solectria PVI-25TL-R GridV.OutLim, Yaskawa Solectria PVI-TL GridF.OutLim, Yaskawa Solectria PVI-TL GridV.OutLim
Same code in other families
Claims
defined_in
c1 drafted · lead
Sungrow SG350HX-US User Manual
reports
c2 drafted · lead
Grid voltage out of range
c3 drafted · lead
Grid frequency out of range
has_event_class
c4 drafted · lead
Fault (device stops or needs intervention)
review note: support check: partial - Cannot connect to grid and service contact is stated, but explicit fault classification is not.
has_production_effect
c5 drafted · lead
Trip (production stops)
has_recovery
c6 drafted · lead
Auto-reset (clears by itself)
detected_by
c7 drafted · lead
Grid frequency measurement
review note: support check: partial - Measuring the actual grid frequency is a check step; not stated as detection method.
mitigated_by
c8 drafted · lead
Utility company consultation
applies_to
c9 drafted · lead
Sungrow SG350HX-US
Data