Solar Lattice

Fault codes › Solis › Solis S6-EH2P(9.6-16)K-SV-YD-L-US

Solis S6-EH2P LmtByFreq

Code
LmtByFreq
Shown as
Frequency power limited
Page
95
ID
fc:solis-s6-eh2p-l-us-lmtbyfreq
IRI
https://solarlattice.org/kb/fc/solis-s6-eh2p-l-us-lmtbyfreq
Status
active
Also known as
LmtByFreq, lmtbyfreq, Solis LmtByFreq, Frequency power limited
Category
Inverters
Class not stated
Production reduced drafted · lead
Clears by itself drafted · lead

Decoded

Reports grid frequency out of range.

What can be behind Grid frequency out of range

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-208 GridF.OutLim, CPS SCA25KTL-480 GridF.OutLim, CPS SCA36KTL GridF.OutLim, CPS SCA50-60KTL GridF.OutLim, CPS SCH100-125KTL GridF.OutLim, CPS SCH125KTL-AIO GridF.OutLim, CPS SCH200-250K-T GridF.OutLim, CPS SCH275KTL GridF.OutLim, CPS SCH350KTL GridF.OutLim
Canadian Solar
Canadian Solar 23-28KTL-CT GridF.OutLim
Fronius
Fronius Galvo 454, Fronius Primo 454, Fronius Symo 454
Huawei
Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
SMA
SMA SB-US-40 501, SMA SB-US-40 701, SMA SB-US-41 0205, SMA SB-US-41 501, SMA SB-US-41 701, SMA SBSE-US-50 501, SMA SBSE-US-50 701, SMA PEAK3-US 501, SMA PEAK3-US 701, SMA CORE1-US 501, SMA STP-TL-US 501, SMA STP-TL-US 701, SMA STP-X-US 501, SMA STP-X-US 701, SMA SC-CP-XT 0205
Schneider Electric
Schneider Electric CL125 054
Solis
Solis S6-EH3P30-60K LmtByFreq, Solis S6-EH3P75-150K LmtByFreq, Solis S6-GC G-F-FLU, Solis S6-GU G-F-FLU
Sungrow
Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GridF.OutLim, Yaskawa Solectria PVI-25TL-R GridF.OutLim, Yaskawa Solectria PVI-TL GridF.OutLim

Same code in other families

Claims

defined_in

c1 drafted · lead Solis_manual_S6-EH2P(9.6-16)K-SV-YD-L-US_V2.7_20260305

reports

c2 drafted · lead Grid frequency out of range

review note: support check: partial - Frequency power limited, but the passages don't say the grid frequency is out of range.

has_production_effect

c3 drafted · lead Derate (output reduced or limited)

has_recovery

c4 drafted · lead Auto-reset (clears by itself)

No action needed; normal operation continues.

review note: support check: partial - No action needed is stated, but auto-clearing is not explicitly stated.

applies_to

c5 drafted · lead Solis S6-EH2P(9.6-16)K-SV-YD-L-US