SMA PEAK3-US 501

Code
501
Shown as
Grid incident
Page
60
ID
fc:sma-shp-peak3-501
IRI
https://solarlattice.org/kb/fc/sma-shp-peak3-501
Status
active
Also known as
501, SMA 501, Grid incident
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports grid frequency out of range; confirm with grid frequency measurement; do: utility company consultation, inverter parameter adjustment.

What can be behind Grid frequency out of range

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-208 GridF.OutLim, CPS SCA25KTL-480 GridF.OutLim, CPS SCA36KTL GridF.OutLim, CPS SCA50-60KTL GridF.OutLim, CPS SCH100-125KTL GridF.OutLim, CPS SCH125KTL-AIO GridF.OutLim, CPS SCH200-250K-T GridF.OutLim, CPS SCH275KTL GridF.OutLim, CPS SCH350KTL GridF.OutLim
Canadian Solar
Canadian Solar 23-28KTL-CT GridF.OutLim
Fronius
Fronius Galvo 454, Fronius Primo 454, Fronius Symo 454
Huawei
Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
SMA
SMA SB-US-40 501, SMA SB-US-40 701, SMA SB-US-41 0205, SMA SB-US-41 501, SMA SB-US-41 701, SMA SBSE-US-50 501, SMA SBSE-US-50 701, SMA PEAK3-US 701, SMA CORE1-US 501, SMA STP-TL-US 501, SMA STP-TL-US 701, SMA STP-X-US 501, SMA STP-X-US 701, SMA SC-CP-XT 0205
Schneider Electric
Schneider Electric CL125 054
Solis
Solis S6-EH2P LmtByFreq, Solis S6-EH3P30-60K LmtByFreq, Solis S6-EH3P75-150K LmtByFreq, Solis S6-GC G-F-FLU, Solis S6-GU G-F-FLU
Sungrow
Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GridF.OutLim, Yaskawa Solectria PVI-25TL-R GridF.OutLim, Yaskawa Solectria PVI-TL GridF.OutLim

Same code in other families

Claims

defined_in

c1 drafted · lead SHPxxx-US-21-BE-en-11

reports

c2 drafted · lead Grid frequency out of range

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - Passages call it a 'Grid fault' and the inverter disconnects, but there is no explicit fault classification.

has_production_effect

c4 drafted · lead Trip (production stops)

detected_by

c5 drafted · lead Grid frequency measurement

review note: support check: partial - Passages say frequency is out of range but don't explicitly state detection by grid frequency measurement; it is only implied.

mitigated_by

c6 drafted · lead Utility company consultation

When fluctuations and the message occur frequently.

c7 drafted · lead Inverter parameter adjustment

Only with grid operator approval, coordinated with service.

applies_to

c8 drafted · lead Sunny Highpower PEAK3