Solar Lattice

Product

Sunny Highpower PEAK3

ID
prod:sma-shp-peak3
IRI
https://solarlattice.org/kb/prod/sma-shp-peak3
Status
active
Also known as
Sunny Highpower PEAK 3, SHP PEAK 3, PEAK 3 US, PEAK3, SHP US 20, SHP xx 20, Sunny High Power PEAK 3, Sunny Highpower PEAK3-US, Sunny Highpower PEAK3 US-20, Sunny Highpower PEAK3 US-21
Category
Inverters
Make
sma
Product level
family

The Sunny Highpower PEAK3 is a family of SMA string inverters. It includes the SHP 100-20 and SHP 150-20, the SHP 100/150/172/180-21, and the US models SHP 125/150/165/172/FLEX-US-21. There are also US-20 models (SHP 125/150-US-20) and Japanese models (SHP 100-JP-20 and SHP 143-JP-20). The inverter supports Modbus TCP for third-party SCADA. Some SHPxx-US-20 units can lose this link at random or for good. A firmware update, a full AC/DC power cycle of at least 15 minutes, or switching the Modbus TCP server off and on may restore it. With the Q on Demand function, the inverter can supply reactive power at night. To do this it draws about 1800 W of active power on average. The filter capacitors cause a reactive power draw. With the grid relays open, this is roughly 127 to 219 VAr per inverter. With the relays closed and operation blocked, it can reach 1089 VAr. If event 6438 appears and the inverter does not feed in, check first that the firmware is 3.11.33.R or higher. If the event stays after a power cycle of at least 5 minutes, check the DC side for ground faults and insulation faults. You can update the firmware automatically through the SMA Data Manager, or by hand through the inverter user interface or a USB drive.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead SMA

uses_protocol

c2 drafted · lead Modbus TCP

SHPxx-US-20 units provide a Modbus TCP server for third-party SCADA systems.

c3 verified · fact Modbus

Modbus function documented for the US-21 models.

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Only a title of a 'Modbus function' page for US-21 is given; the content isn't shown, though it implies Modbus use.

implements

c4 verified · fact Reactive power at night

Called Q on Demand. During non-feed-in operation the inverter stays connected and draws about 1800 W of active power on average to cover its losses.

verified by: review-workflowverified on: 2026-10-24

c5 verified · fact Remote firmware update

Automatic firmware updates can be enabled through the SMA Data Manager or on US-21 models. Manual update is possible through the inverter UI or a USB drive.

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Automatic updates via Data Manager and manual update via UI or USB are stated, but 'remote' and the US-21 automatic update claim rest only on a title; the Data Manager link isn't specific to US-21.

compatible_with

c6 drafted · lead SMA Data Manager M

The Data Manager can show the inverter firmware version and run automatic updates.

review note: support check: partial - Data Manager use for firmware check and automatic updates is stated, but the specific model 'Data Manager M' isn't named.

Referenced by