Solar Lattice

Product

SMA Data Manager M

ID
prod:sma-data-manager-m
IRI
https://solarlattice.org/kb/prod/sma-data-manager-m
Status
active
Also known as
Data Manager M, EDMM, EDMM-10, EDMM-US-10, EDMM-20, ennexOS Data Manager M
Category
Monitoring and communications
Make
sma
Product level
family

The SMA Data Manager M (EDMM) is a data logger that reports to the ennexOS portal, which is the successor of Sunny Portal. Each Data Manager M handles up to 50 devices. Bigger systems use several units, with one set as master and the others as slaves, and the total system power may not exceed 2.5 MVA; above that a Data Manager L must be the master. Only one measuring device is supported at the point of interconnection. That energy meter must be assigned to the master unit, and only the master can do control. It talks to SMA devices over Speedwire, to RS485 devices, and to Modbus devices such as the Sunny Tripower CORE2 using the SunSpec Modbus profile with Unit ID 1. From firmware 2.5.9.R, the EDMM-20 can monitor up to 20 SMA eChargers over Modbus TCP, but it cannot control them. It supports Q(U) reactive power control, power setpoints sent as pulse signals, a WAGO 750 I/O system, and firmware updates of connected SMA products. The Sunny SensorBox, Windy Boy, Hydro Boy and SolTrk are not supported. Function button: hold 5 to 10 seconds to restart, 10 to 15 seconds to reset the admin account, and 15 to 20 seconds to restore factory settings, which erases all data. If the user interface shows no data, the real-time clock buffer capacitor may have discharged after a long time without power, so check that the unit can reach an internet time server.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead SMA

review note: support check: partial - Passages show the product name and SMA-branded manuals/service site, but never explicitly state SMA makes it; implied by naming only.

instance_of

c2 drafted · lead Monitoring data logger

max_count

c3 drafted · lead ≤ 50 NUM

Conditions: Devices per Data Manager M; larger systems need several Data Managers M in master/slave configuration

c4 drafted · lead ≤ 20 NUM

Conditions: SMA eChargers (charging points) via Modbus TCP, monitoring only, EDMM-20

uses_protocol

c5 drafted · lead Modbus TCP

c6 drafted · lead SunSpec Modbus

Sunny Tripower CORE2 is controlled and monitored via SunSpec Modbus profile with Unit ID 1

c7 drafted · lead SMA Speedwire

c8 drafted · lead RS-485

c9 drafted · lead Wi-Fi

Soft access Wi-Fi for local commissioning login

compatible_with

c10 drafted · lead Sunny Tripower CORE2

c11 drafted · lead SMA Com Gateway proposed

Compatible RS485 devices behind a Com Gateway can be used; SMA Meteo Station only with restrictions

c12 drafted · lead SMA eCharger proposed

Scope: firmware from 2.5.9.R

Conditions: Monitoring only, no control; eCharger and Data Manager M firmware 2.5.9.R or later; EDMM-20

incompatible_with

c13 drafted · lead Sunny SensorBox

supersedes

c14 drafted · lead SMA Data Manager M Lite proposed

EDMM-10.A discontinued; EDMM-10 named as alternative and substitute

review note: support check: partial - M Lite discontinued and EDMM-10 named as alternative/substitute, but 'supersedes' is not stated exactly.

implements

c15 drafted · lead Volt-VAr

Reactive power as a function of grid voltage, Q(U)

review note: support check: partial - Articles refer to configuring reactive power as function of grid voltage in the manual; implies support but sparse and no explicit Volt-VAr statement.

c16 drafted · lead Closed-loop plant control

Only a Data Manager M in master mode performs control

c17 drafted · lead Remote firmware update

Updates firmware of connected SMA products

c18 drafted · lead Power reduction via digital inputs

Transfer of power specifications via pulse signals

review note: support check: partial - Only a title 'Transfer of power specifications via pulse signals' for EDMM; no explicit digital-input power reduction detail.

Referenced by

Data