CPS SCH275KTL GridF.OutLim
- Code
GridF.OutLim
- Vendor severity
- Protection
- Page
- 72
- ID
fc:chint-sch-275ktl-gridfoutlim
- IRI
https://solarlattice.org/kb/fc/chint-sch-275ktl-gridfoutlim
- Status
- active
- Also known as
- GridF.OutLim, gridfoutlim, CPS GridF.OutLim
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports grid frequency out of range; confirm with grid frequency measurement; do: AC connection check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- CPS
- CPS SCA25KTL-208 GridF.OutLim, CPS SCA25KTL-480 GridF.OutLim, CPS SCA36KTL GridF.OutLim, CPS SCA50-60KTL GridF.OutLim, CPS SCH100-125KTL GridF.OutLim, CPS SCH125KTL-AIO GridF.OutLim, CPS SCH200-250K-T GridF.OutLim, CPS SCH350KTL GridF.OutLim
- Canadian Solar
- Canadian Solar 23-28KTL-CT GridF.OutLim
- Fronius
- Fronius Galvo 454, Fronius Primo 454, Fronius Symo 454
- Huawei
- Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- SMA
- SMA SB-US-40 501, SMA SB-US-40 701, SMA SB-US-41 0205, SMA SB-US-41 501, SMA SB-US-41 701, SMA SBSE-US-50 501, SMA SBSE-US-50 701, SMA PEAK3-US 501, SMA PEAK3-US 701, SMA CORE1-US 501, SMA STP-TL-US 501, SMA STP-TL-US 701, SMA STP-X-US 501, SMA STP-X-US 701, SMA SC-CP-XT 0205
- Schneider Electric
- Schneider Electric CL125 054
- Solis
- Solis S6-EH2P LmtByFreq, Solis S6-EH3P30-60K LmtByFreq, Solis S6-EH3P75-150K LmtByFreq, Solis S6-GC G-F-FLU, Solis S6-GU G-F-FLU
- Sungrow
- Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL GridF.OutLim, Yaskawa Solectria PVI-25TL-R GridF.OutLim, Yaskawa Solectria PVI-TL GridF.OutLim
Same code in other families
Claims
defined_in
c1 drafted · lead
CPS SCH275KTL-DO-US-800 V2 User Manual Rev 1.7
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the table header
reports
c3 drafted · lead
Grid frequency out of range
detected_by
c4 drafted · lead
Grid frequency measurement
Compare measured frequency on display against limits
mitigated_by
c5 drafted · lead
AC connection check
has_production_effect
c6 drafted · lead
Trip (production stops)
Restart needed implies inverter stopped
review note: support check: partial - Restart instruction implies stoppage but trip is not explicitly stated.
has_recovery
c7 drafted · lead
Manual reset (operator restarts or acknowledges)
Restart once frequency is within limits
applies_to
c8 drafted · lead
CPS SCH275KTL-DO/US-800
Data