Solar Lattice

Fault codes › SMA › Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)

SMA SB-US-40 701

Code
701
Shown as
Frq. not permitted > Check parameter
Page
48
ID
fc:sma-sb-us-40-701
IRI
https://solarlattice.org/kb/fc/sma-sb-us-40-701
Status
active
Also known as
701, SMA 701, Frq. not permitted > Check parameter
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports grid frequency out of range; confirm with grid frequency measurement; do: AC connection check, utility company consultation, inverter parameter adjustment.

What can be behind Grid frequency out of range

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-208 GridF.OutLim, CPS SCA25KTL-480 GridF.OutLim, CPS SCA36KTL GridF.OutLim, CPS SCA50-60KTL GridF.OutLim, CPS SCH100-125KTL GridF.OutLim, CPS SCH125KTL-AIO GridF.OutLim, CPS SCH200-250K-T GridF.OutLim, CPS SCH275KTL GridF.OutLim, CPS SCH350KTL GridF.OutLim
Canadian Solar
Canadian Solar 23-28KTL-CT GridF.OutLim
Fronius
Fronius Galvo 454, Fronius Primo 454, Fronius Symo 454
Huawei
Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
SMA
SMA SB-US-40 501, SMA SB-US-41 0205, SMA SB-US-41 501, SMA SB-US-41 701, SMA SBSE-US-50 501, SMA SBSE-US-50 701, SMA PEAK3-US 501, SMA PEAK3-US 701, SMA CORE1-US 501, SMA STP-TL-US 501, SMA STP-TL-US 701, SMA STP-X-US 501, SMA STP-X-US 701, SMA SC-CP-XT 0205
Schneider Electric
Schneider Electric CL125 054
Solis
Solis S6-EH2P LmtByFreq, Solis S6-EH3P30-60K LmtByFreq, Solis S6-EH3P75-150K LmtByFreq, Solis S6-GC G-F-FLU, Solis S6-GU G-F-FLU
Sungrow
Sungrow SG-CX-US 013, Sungrow SG200HX 013, Sungrow SG250HX 13, Sungrow SG350HX 013
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GridF.OutLim, Yaskawa Solectria PVI-25TL-R GridF.OutLim, Yaskawa Solectria PVI-TL GridF.OutLim

Same code in other families

Claims

defined_in

c1 drafted · lead SBxx-US-1XP-40-BA-en-13

reports

c2 drafted · lead Grid frequency out of range

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

has_production_effect

c4 drafted · lead Trip (production stops)

detected_by

c5 drafted · lead Grid frequency measurement

review note: support check: partial - Corrective measures involve checking grid frequency, but detection by frequency measurement is only implied.

mitigated_by

c6 verified · fact AC connection check

verified by: review-workflowverified on: 2026-10-23

c7 drafted · lead Utility company consultation

When frequency fluctuations and this message occur often.

c8 drafted · lead Inverter parameter adjustment

Only with grid operator approval, coordinated with manufacturer service.