Solar Lattice

Fault codes › SMA

SMA fault codes

Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)

CodeShown asClassProductionClearsReportsPage
101-105Grid fault fault stops Grid overvoltage, High grid impedance 46
202-206Grid fault fault stops Grid loss, Grid undervoltage 46
401-404Grid fault fault stops Islanding detected 47
501Grid fault fault stops Grid frequency out of range 47
601Grid fault High DC injection 47
701Frq. not permitted > Check parameter fault stops Grid frequency out of range 48
1001L/N swapped > Check connection AC polarity reversed 48
1302 fault stops Grid loss, Phase loss 48
1501Reconnection fault grid fault stops Configuration error 48
3301-3303Unstable operation stops Insufficient DC input power 49
3401-3407DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 49
3501Insulation failure > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 49
3601High discharge curr. > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 50
3701Resid.curr.too.high > Check generator fault stops by itself Ground fault alarm or trip 50
3801DC overcurrent > Check generator stops by itself DC overcurrent 50
3901-3902 by itself Insufficient solar irradiance 50
4301Electric arc detected > Check DC generator fault stops after a manual reset 51
6512 stops by itself Inverter undertemperature 51
6701-6702 warning unaffected needs service Internal communication failure 51
6803 Reverse polarity 51
6903 Reverse polarity 51
7106 warning unaffected Firmware update failure 51
7110 warning unaffected Firmware update failure 51
7112 informational 52
7113 Memory card not writable 52
7303 needs service Firmware update failure 52
7324 Firmware update failure 52
7331 informational 52
7332 informational 52
7333 Firmware update failure 52
7340 Firmware update failure 52
7347Incompatible file Configuration error 53
7348Incorrect file format Configuration error 53
7350 informational 53
7351 informational 53
7352Update of WLAN not successful Firmware update failure 53
7353Update time zone database informational 53
7354Update of time zone database not successful Time zone update failure 53
7355 informational 54
7356Update of the WebUI not successful Firmware update failure 54
7619 Communication loss 54
8003Active power limited derating warning reduced Inverter overtemperature 54
8206Electr. arc detected > Please confirm by tapping fault stops after a manual reset Operation inhibited 55
8503Self-diagnosis > Input C defective needs service Reverse polarity 55
8708Timeout in communication for active power limitation reduced Communication loss 55
8801-8803No display 55
9002SMA Grid Guard code invalid informational Invalid access code 55
9003Grid parameter locked informational Parameter change rejected 55
9005 Parameter change rejected, Insufficient DC input power 56
9202SPS AC overvoltage needs service Backup output AC overvoltage 56
9203Short circuit in the SPS power outlet after a manual reset Backup outlet short circuit 56
10110Time synchronization failed: [x] Time synchronization failure 56
10248-10249 Degraded network link 57
10250[Interface]: package error rate [ok / high] High network packet error rate 57
10251 informational 57
10252[Interface]: communication disrupted Communication loss 57
10253 informational Degraded network link 58
10254[Interface]: duplex mode goes to [Full / Half] Degraded network link 58
10255[Interface]: Network load OK informational unaffected 58
10282[User group]-Login via [protocol] locked informational by itself Invalid access code 58
10283WLAN module faulty needs service 58
10284No WLAN connection possible warning Communication loss 59
10285WLAN connection established informational unaffected 59
10286WLAN connection lost warning Communication loss 59
10339Webconnect enabled informational unaffected 59
10340Webconnect disabled informational 59
10341Webconnect error: no connection Communication loss 60
10343Webconnect error: Default gateway not configured Configuration error 60
10344Webconnect error: DNS server not configured Configuration error 60
10345No reply to DNS request Communication loss 60
10346SIP proxy DNS resolution failed Communication loss 61
10347Stun server DNS resolution failed Communication loss 61
10348 Communication loss 61
10349Webconnect error: No reply to SIP option packs Communication loss 62
10350Webconnect error: Registration rejected by SIP registrar Communication loss 62
10351Unknown SIP registry Communication loss 62
10352Webconnect error: Faulty communication Communication loss 63
10353 Communication loss 63
27107 informational 63
27108 informational 63
27109 informational 63
27301 informational 63
27302 informational 63
27312 informational 63
27331 informational 64
27332 informational 64
29001 informational 64
29004 informational Parameter change rejected 64

Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)

CodeShown asClassProductionClearsReportsPage
101Grid incident fault stops Grid overvoltage, High grid impedance 49
102Grid incident fault stops Grid overvoltage, High grid impedance 50
0103Grid incident fault stops by itself Grid overvoltage, High grid impedance 50
105Grid incident fault stops Grid overvoltage, High grid impedance 51
202Grid incident fault stops Grid undervoltage, Grid loss 51
0203Grid incident fault stops by itself Grid undervoltage, Grid loss 51
0205Grid incident fault stops by itself Grid synchronization failure, Grid frequency out of range 52
206Grid incident fault stops Grid undervoltage, Grid loss 52
301Grid incident fault stops Grid overvoltage 53
401Grid incident fault stops Islanding detected 53
404Grid incident fault stops by itself Islanding detected, Grid instability 54
501Grid incident fault stops Grid frequency out of range 54
601Grid incident High DC injection 54
701Frequency not permitted > Check parameter fault stops Grid frequency out of range 55
1001L / N swapped AC polarity reversed 55
1302 fault stops Grid loss, Phase loss 55
1501Reconnection fault grid fault stops Configuration error 56
3301Unstable operation fault stops by itself Insufficient DC input power, Insufficient solar irradiance 56
3303Unstable operation fault stops by itself Insufficient DC input power, Insufficient solar irradiance 56
3401DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 57
3402DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 57
3407DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 58
3501Insulation failure > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 58
3601High discharge current > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 58
3701Residual current too high > Check generator fault stops by itself Ground fault alarm or trip 59
3801Residual current too high > Check generator stops by itself DC overcurrent 59
3802Residual current too high > Check generator stops by itself DC overcurrent 59
3805Residual current too high stops by itself DC overcurrent 59
3901 stops by itself Insufficient DC input power 60
3902 stops by itself Insufficient DC input power 60
4301 fault stops after a manual reset 61
6512Minimum operating temperature not reached stops by itself Inverter undertemperature 61
6701Communication impaired warning unaffected Internal communication failure 61
6702Communication impaired warning unaffected Internal communication failure 61
6803Self-diagnosis > Input A defective Reverse polarity 62
6903Self-diagnosis > Input B defective Reverse polarity 62
7106 warning unaffected Firmware update failure 62
7110No update file found warning unaffected Firmware update failure 62
7112Update file successfully copied informational 63
7113The memory card is full or write-protected Memory card not writable 63
7303Update main CPU failed needs service Firmware update failure 63
7324Wait for update conditions Firmware update failure 63
7331Update transport started informational 63
7332Update transport successful informational 64
7333Update transport failed Firmware update failure 64
7340Update communication failed Firmware update failure 64
7347Incompatible file Configuration error 64
7348Incorrect file format Configuration error 65
7350Transfer of a configuration file has started informational 65
7351Update Wi-Fi informational 65
7352Update of Wi-Fi not successful Firmware update failure 65
7353Update time zone database informational 66
7354Update of time zone database not successful Time zone update failure 66
7355Update WebUI informational 66
7356Update of WebUI not successful Firmware update failure 66
7619 Communication loss 66
8003Temperature derating warning reduced Inverter overtemperature 67
8006 informational reduced Inverter power derating
8206Electric arc detected fault stops after a manual reset Operation inhibited 67
8503Self-diagnosis > Input C defective needs service Reverse polarity 67
8708Timeout in communication for active power limitation reduced Communication loss 68
8801No display Display unavailable 68
8803No display Display unavailable 68
9002Installer code invalid informational Invalid access code 68
9003Grid parameter locked informational Parameter change rejected 69
9005Waiting for main CPU Parameter change rejected, Insufficient DC input power 69
9034Error in the rapid shutdown system Rapid shutdown failure 69
9037Generator not connected stops PV array not connected 70
9202SPS AC overvoltage needs service Backup output AC overvoltage 70
9203Short circuit in the SPS power outlet after a manual reset Backup outlet short circuit 70
10110Time synchronization failed |d0| Time synchronization failure 71
10248|tn4|: network busy warning Degraded network link 71
10249|tn4|: network busy Communication loss 71
10250|tn4|: faulty data packages |tn8| High network packet error rate 71
10251 informational 72
10252[|tn4|: communication disrupted Communication loss 72
10253|tn4|: connection speed goes to |tn8| informational Degraded network link 72
10254|tn4|: duplex mode goes to |tn8| Degraded network link 73
10255[Interface]: Network load OK informational unaffected 73
10282|tn0|-Login via |tn4| locked informational by itself Invalid access code 73
10283WiFi module faulty needs service 73
10284No WiFi connection possible warning Communication loss 74
10285WiFi connection established informational unaffected 74
10286Wi-Fi connection lost warning Communication loss 74
10339Webconnect enabled informational unaffected 74
10340Webconnect disabled informational 75
10341Webconnect error: no connection Communication loss 75
10343Webconnect error: Default gateway not configured Configuration error 75
10344Webconnect error: DNS server not configured Configuration error 75
10345No reply to DNS request Communication loss 76
10346SIP proxy DNS resolution failed Communication loss 76
10347Stun server DNS resolution failed Communication loss 77
10348 Communication loss 77
10349Webconnect error: No reply to SIP option packs Communication loss 77
10350Webconnect error: Registration rejected by SIP registrar Communication loss 78
10351Unknown SIP registry Communication loss 78
10352Webconnect error: Faulty communication Communication loss 78
10353 Communication loss 79
27107Update file OK informational 79
27108Memory card is read informational 80
27109No new update on the memory card informational 80
27301Update communication informational 80
27302Update main CPU informational 80
27312Update completed informational 80
27331Update transport started informational 80
27332Update transport successful informational 80
29001SMA Grid Guard code valid informational 81
29004Grid parameter unchanged informational Parameter change rejected 81

Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50)

CodeShown asClassProductionClearsReportsPage
101Grid incident fault stops Grid overvoltage, High grid impedance 97
102Grid incident fault stops Grid overvoltage, High grid impedance 97
0103Grid incident fault stops by itself Grid overvoltage, High grid impedance 97
105Grid incident fault stops Grid overvoltage, High grid impedance 98
202Grid incident fault stops Grid undervoltage, Grid loss 98
0203Grid incident fault stops by itself Grid undervoltage, Grid loss 99
206Grid incident fault stops Grid undervoltage, Grid loss 99
301Grid incident fault stops Grid overvoltage 99
302Active power limited AC voltage reduced Grid overvoltage 100
401Grid incident fault stops Islanding detected 100
404Grid incident fault stops by itself Islanding detected, Grid instability 100
501Grid incident fault stops Grid frequency out of range 101
507Active power limit AC frequency reduced Grid overfrequency 101
601Grid incident High DC injection 101
701Frequency not permitted > Check parameter fault stops Grid frequency out of range 102
901PE connection missing > Check connection Missing ground connection 102
1001L / N swapped AC polarity reversed 102
1101Installation error > Check connection Abnormal neutral line 103
1302 fault stops Grid loss, Phase loss 103
1501Reconnection fault grid fault stops Configuration error 103
3302Unstable operation fault stops by itself Insufficient DC input power, Insufficient solar irradiance 103
3303Unstable operation fault stops by itself Insufficient DC input power, Insufficient solar irradiance 104
3401DC overvoltage > Disconnecting generator fault after a manual reset DC overvoltage 104
3402DC overvoltage > Disconnecting generator fault after a manual reset DC overvoltage 105
3407DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 105
3410DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 105
3411DC overvoltage > Disconnect generator fault after a manual reset DC overvoltage 106
3501Ground fault > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 106
3523Start of cyclic insulation test informational by itself 106
3601High leakage current > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 107
3701Residual current too high > Check generator fault stops by itself Ground fault alarm or trip 107
3901 stops by itself Insufficient DC input power 107
3902 stops by itself Insufficient DC input power 108
4013 Reverse polarity, String reverse current 108
4014 Reverse polarity, String reverse current 108
4015 Reverse polarity, String reverse current 109
4016 Reverse polarity, String reverse current 109
4017 Reverse polarity, String reverse current 109
4301 fault stops after a manual reset 110
6001-6499Self-diagnosis > Interference device fault needs service Internal device fault 110
6501Self-diagnosis > Overtemperature fault stops Inverter overtemperature 110
6502Self-diagnosis > Overtemperature fault stops Inverter overtemperature 111
6509Self-diagnosis > Overtemperature fault stops Inverter overtemperature 111
6511Self-diagnosis > Overtemperature Inverter overtemperature 111
6512Minimum operating temperature not reached stops by itself Inverter undertemperature 112
6602Overvoltage grid (SW) Grid overvoltage 112
6606Self-diagnosis > Device fault needs service Internal device fault 112
6633Self-diagnosis > Device fault fault needs service Internal device fault 112
6801Self-diagnosis > Input A defective needs service Abnormal PV input 113
6901Self-diagnosis > Input B defective needs service Abnormal PV input 113
7001Fault sensor interior temperature fault stops needs service 113
7002Fault sensor interior temperature fault stops needs service 113
7014Fault boost converter temperature sensor needs service 114
7015Fault sensor interior temperature fault stops needs service 114
7702Self-diagnosis > Interference device fault stops needs service Internal device fault 114
7703Self-diagnosis > Interference device fault stops needs service Internal device fault 114
8003Temperature derating warning reduced Inverter overtemperature 115
8104Communication impaired needs service Communication loss 115
8205AFCI self-test successful informational 115
8503Self-diagnosis > Input C defective needs service Reverse polarity 115
8708Timeout in communication for active power limitation reduced Communication loss 116
8709Timeout in communication for reactive power spec. reduced Communication loss 116
8710 unaffected Communication loss 116
9007Abort self-test Self-test failure 117
9033Rapid shutdown has been triggered stops Rapid shutdown triggered 117
9034Error in the rapid shutdown system Rapid shutdown failure 117
9035Rapid shutdown performed successfully informational 118
9037Generator not connected stops PV array not connected 118
9038Redundant rapid shutdown discharge function not assured needs service Rapid shutdown failure 118
9101AC voltage calibration failed. needs service Calibration failure 118
9102Permanent operation inhibition fault stops after a manual reset Operation inhibited 119
9107Self-diagnosis > Interference device needs service Internal device fault 119
9202AC overvoltage in backup operation needs service Backup output AC overvoltage 119
9203Short circuit in backup operation after a manual reset Backup outlet short circuit 119
9308Battery system communication error Communication loss 120
9342DC connection, polarity reversed > Check connection Reverse polarity 120
9345Battery charge too low for start procedure stops needs service Low battery state of charge 120
9350Timeout for battery status change Battery state change timeout 121
9394Deep discharge protection activated informational Battery deep discharge protection 121
9395Battery separated externally Battery disconnected 121
29252Backup operation not possible Backup mode unavailable 121
29254Input power too low for backup operation Insufficient DC input power 121

Sunny Highpower PEAK3 (SHP 125-172-US)

CodeShown asClassProductionClearsReportsPage
501Grid incident fault stops Grid frequency out of range 60
0502Grid incident fault stops by itself Grid underfrequency 60
0503Grid incident fault stops by itself Grid overfrequency 60
507Active power limit AC frequency reduced Grid overfrequency 61
601Grid incident High DC injection 61
701Frequency not permitted > Check parameter fault stops Grid frequency out of range 61
1302 fault stops Grid loss, Phase loss 62
1501Reconnection fault grid fault stops Configuration error 62
3501Insulation failure > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 62
3601High discharge current > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 63
3701Residual current too high > Check generator fault stops by itself Ground fault alarm or trip 63
6001-6499Self-diagnosis > Interference device fault needs service Internal device fault 63
6128 stops by itself Grid overvoltage
6438 fault stops after a manual reset Internal device fault
6501Self-diagnosis > Overtemperature fault stops Inverter overtemperature 63
6511Self-diagnosis > Overtemperature Inverter overtemperature 64
6512Minimum operating temperature not reached stops by itself Inverter undertemperature 64
6701Communication impaired warning unaffected Internal communication failure 64
7001Fault sensor interior temperature fault stops needs service 64
7102Parameter file not found or defective warning unaffected Parameter download failure 65
7303Update main CPU failed needs service Firmware update failure 65
7324Wait for update conditions Firmware update failure 65
7330Wait for update conditions Firmware update failure 65
7333Update transport failed Firmware update failure 66
7347Incompatible file Configuration error 66
7348Incorrect file format Configuration error 66
7349Incorrect login rights for configuration file Insufficient user rights 67
7619 Communication loss 67
7701Self-diagnosis > Interference device needs service Internal device fault 67
7801Fault overvoltage protector warning Surge protector alarm 67
8003Temperature derating warning reduced Inverter overtemperature 68
8101Communication impaired needs service Communication loss 68
8708Timeout in communication for active power limitation reduced Communication loss 68
8709Timeout in communication for reactive power spec. reduced Communication loss 69
8710 unaffected Communication loss 69
9002Installer code invalid informational Invalid access code 69
9003Grid parameter locked informational Parameter change rejected 69
9007Abort self-test Self-test failure 70
9107Self-diagnosis > Interference device needs service Internal device fault 70
10110Time synchronization failed |d0| Time synchronization failure 70
10248|tn4|: network busy warning Degraded network link 70
10249|tn4|: network busy Communication loss 71
10250|tn4|: faulty data packages |tn8| High network packet error rate 71
10252[|tn4|: communication disrupted Communication loss 71
10253|tn4|: connection speed goes to |tn8| informational Degraded network link 72
10254|tn4|: duplex mode goes to |tn8| Degraded network link 72
10282|tn0|-Login via |tn4| locked informational by itself Invalid access code 72

Sunny Tripower CORE1-US (STP 33/50/62-US-41)

CodeShown asClassProductionClearsReportsPage
101Grid incident fault stops Grid overvoltage, High grid impedance 47
301Grid incident fault stops Grid overvoltage 47
401Grid incident fault stops Islanding detected 47
501Grid incident fault stops Grid frequency out of range 47
601Grid incident High DC injection 47
801 stops Grid loss 48
901Grounding connection missing > Check connection Missing ground connection 48
3401DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 48
3402DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 49
3404DC overvoltage > Disconnect PV array fault DC overvoltage 49
3407DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 49
3410DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 49
3411DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 49
3412DC overvoltage > Disconnect PV array fault after a manual reset DC overvoltage 49
3501Insulation failure > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 48
3701Residual current too high > Check PV array fault stops by itself Ground fault alarm or trip 49
3801 stops by itself DC overcurrent 49
3802DC overcurrent > Check PV array stops by itself DC overcurrent 49
3803 stops by itself DC overcurrent 49
3805 stops by itself DC overcurrent 49
3806 stops by itself DC overcurrent 49
3807 stops by itself DC overcurrent 49
3808 stops by itself DC overcurrent 49
4301 fault stops after a manual reset 49
4302 after a manual reset 49
6002-6412Self-diagnosis > Device disturbance needs service Internal device fault 49
6107 fault stops by itself Internal device fault
6502 fault stops Inverter overtemperature 49
6512 stops by itself Inverter undertemperature 49
6603Self-diagnosis > Overload needs service Inverter overload 49
6604 needs service 49
6701 warning unaffected Internal communication failure 50
6702 warning unaffected Internal communication failure 50
7102 warning unaffected Parameter download failure 50
7105 warning unaffected Parameter change rejected, Configuration error 50
7106 warning unaffected Firmware update failure 50
7110 warning unaffected Firmware update failure 50
7112 informational 50
7113 Memory card not writable 50
7201 Data storage failure 50
7202 Data storage failure 50
7303 needs service Firmware update failure 50
7320 informational 50
7330 Firmware update failure 51
7331 informational 51
7332 informational 51
7333Update transport failed Firmware update failure 49
7341Update Bootloader 52
7342Update Bootloader failed Firmware update failure 51
7347Incompatible file Configuration error 51
7348Incorrect file format Configuration error 51
7350 informational 52
7351 informational 52
7352 Firmware update failure 52
7353 informational 52
7354 Time zone update failure 52
7355 informational 52
7356 Firmware update failure 52
7619 Communication loss 52
7622 fault stops Internal communication failure 52
7702Device fault fault stops needs service Internal device fault 54
7801Fault overvoltage protector warning Surge protector alarm 54
8003Active power limit Temperature warning reduced Inverter overtemperature 54
8101Communication failure needs service Communication loss 54
8102Communication failure needs service Communication loss 54
8103Communication failure needs service Communication loss 54
8104 needs service Communication loss 54
8206 fault stops after a manual reset Operation inhibited
8208 needs service Self-test failure 54
8209 needs service Self-test failure 54
8210
8212
9002 informational Invalid access code 54
9003 informational Parameter change rejected 54
9005 Parameter change rejected, Insufficient DC input power 54
9007 Self-test failure 54
9033 stops Rapid shutdown triggered 54
9034Error in Rapid Shutdown System Rapid shutdown failure 55
9035 informational 55
9037 stops PV array not connected 55
9038 needs service Rapid shutdown failure 55
10108 informational 55
10109 informational 55
10110 Time synchronization failure 55
10118 informational 55
10248[Interface]: network busy warning Degraded network link 57
10249[Interface]: network overloaded Communication loss 56
10250[Interface]: package error rate [ok / high] High network packet error rate 56
10251 informational 57
10252[Interface]: communication disrupted Communication loss 56
10253 informational Degraded network link 58
10254[Interface]: duplex mode goes to [Full / Half] Degraded network link 57
10255 informational unaffected 58
10282 informational by itself Invalid access code 58
10283Wi-Fi module faulty needs service 57
10284No Wi-Fi connection possible warning Communication loss 59
10285Wi-Fi connection established informational unaffected 58
10286Wi-Fi connection lost warning Communication loss 58
10339 informational unaffected 59
10340 informational 59
10431 informational 59
10433
10502 reduced Inverter power derating 59
10513 stops Remote shutdown 59
10901 informational 59
10902 informational 59
10903 informational 59
10904 informational 59
10905 informational 59
10906 informational 59
10907 informational 59
10908 informational 59
10909 informational 59
10910 informational 59
10911 informational 59
10912 informational 59
27103 informational 59
27104 informational 59
27107 informational 59
27301 informational 59
27302 informational 59
27312 informational 59
29001 informational 59
29004 informational Parameter change rejected 59

Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)

CodeShown asClassProductionClearsReportsPage
101-103Grid fault fault stops Grid overvoltage, High grid impedance 45
202-203Grid fault fault stops Grid undervoltage, Grid loss 45
301 fault stops Grid overvoltage 46
401 fault stops Islanding detected 46
404 fault stops by itself Islanding detected, Grid instability 46
501 fault stops Grid frequency out of range 46
601 High DC injection 47
701 fault stops Grid frequency out of range 47
901 Missing ground connection 47
1302 fault stops Grid loss, Phase loss 47
1501 fault stops Configuration error 47
3301Unstable operation > Generator output too low fault stops by itself Insufficient DC input power, Insufficient solar irradiance 48
3302Unstable operation > Abort self-test fault stops by itself Insufficient DC input power, Insufficient solar irradiance 48
3303Unstable operation > Data storage blocked fault stops by itself Insufficient DC input power, Insufficient solar irradiance 48
3401-3402DC overvoltage > Disconnect generator fault DC overvoltage 49
3501 fault stops Ground fault alarm or trip, Low insulation resistance 49
3601High discharge curr. > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 49
3701Resid.curr.too.high > Check generator fault stops by itself Ground fault alarm or trip 49
3801-3802 stops by itself DC overcurrent 49
3901-3902 by itself Insufficient solar irradiance 50
4301 fault stops after a manual reset 50
6001-6438Self diagnosis > Interference device needs service Internal device fault 50
6501-6511Self diagnosis > Interference device fault stops Inverter overtemperature 50
6512 stops by itself Inverter undertemperature 50
6603-6604Self-diagnosis > Overload needs service Inverter overload 50
6606 needs service Internal device fault 50
6701-6702 warning unaffected needs service Internal communication failure 51
6801-6802Self-diagnosis > Input needs service Abnormal PV input 51
6901-6902Self-diagnosis > Input B defective needs service Abnormal PV input 51
7001-7002 needs service Measurement signal error 51
7101 Memory card not writable 51
7102 warning unaffected Parameter download failure 52
7105 warning unaffected Parameter change rejected 51
7106 warning unaffected Firmware update failure 51
7110 warning unaffected Firmware update failure 52
7201-7202 warning unaffected needs service Data storage failure 52
7303 needs service Firmware update failure 52
7305 Firmware update failure 52
7311 Firmware update failure 52
7316 Firmware update failure 52
7324 Firmware update failure 52
7326 Firmware update failure 53
7508External fan fault > Replace fan Fan fault alarm 53
7701-7703Self diagnosis > Interference device needs service Internal device fault 53
8001 reduced Inverter overtemperature, Inverter power derating 53
8101-8104 needs service Communication loss 53
8204 needs service Self-test failure 53
8206Electr. arc detected > Please confirm by tapping fault stops after a manual reset Operation inhibited 54
8708 reduced Communication loss 54
8709 reduced Communication loss 54
8710 unaffected Communication loss 54
9002 informational Invalid access code 54
9003 informational Parameter change rejected 55
9005 Parameter change rejected, Insufficient DC input power 55
27103 informational 55
27104 informational 55
27107 informational 55
27108 informational 55
27109 informational 55
27301 informational 55
27302 informational 55
27304 informational 55
27310 informational 55
27312 informational 55
27317 informational 55
27325 informational 55
28205 informational 55
29001 informational 56
29004 informational Parameter change rejected 56

Sunny Tripower X 13-30-US (STP xx-US-50)

CodeShown asClassProductionClearsReportsPage
101Grid incident fault stops Grid overvoltage, High grid impedance 79
102Grid incident fault stops Grid overvoltage, High grid impedance 79
0103Grid incident fault stops by itself Grid overvoltage, High grid impedance 79
105Grid incident fault stops Grid overvoltage, High grid impedance 80
301Grid incident fault stops Grid overvoltage 80
302Active power limited AC voltage reduced Grid overvoltage 81
401Grid incident fault stops Islanding detected 81
404Grid incident fault stops by itself Islanding detected, Grid instability 81
501Grid incident fault stops Grid frequency out of range 81
507Active power limit AC frequency reduced Grid overfrequency 82
601Grid incident High DC injection 82
701Frequency not permitted > Check parameter fault stops Grid frequency out of range 82
1001L / N swapped AC polarity reversed 83
1101Installation error > Check connection Abnormal neutral line 83
1302 fault stops Grid loss, Phase loss 83
1501Reconnection fault grid fault stops Configuration error 84
3501Insulation failure > Check generator fault stops Ground fault alarm or trip, Low insulation resistance 84
3523Start of cyclic insulation test informational by itself 85
3601High discharge current > Check generator fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 85
3701Residual current too high > Check generator fault stops by itself Ground fault alarm or trip 85
3901 stops by itself Insufficient DC input power 86
3902 stops by itself Insufficient DC input power 87
4301 fault stops after a manual reset 87
6001-6499Self-diagnosis > Interference device fault needs service Internal device fault 88
6101Interference device / DevFlt > Self-diagnosis/ SlfDiag fault stops by itself Internal device fault 88
6107 fault stops by itself Internal device fault 88
6202Self-diagnosis > Interference device fault stops Internal device fault 89
6401Self-diagnosis > Interference device fault stops by itself Internal device fault 89
6404Self-diagnosis > Interference device fault stops by itself AC overcurrent 90
6405Self-diagnosis > Interference device by itself DC bus overvoltage 90
6406Self-diagnosis > Interference device DC overcurrent 90
6407Self-diagnosis > Interference device DC overcurrent 91
6422Self-diagnosis > Interference device fault after a manual reset Internal device fault 91
6438Self-diagnosis > Interference device fault stops after a manual reset Internal device fault 91
6501Self-diagnosis > Overtemperature fault stops Inverter overtemperature 92
6511Self-diagnosis > Overtemperature Inverter overtemperature 92
6512Minimum operating temperature not reached stops by itself Inverter undertemperature 93
6521
6602Overvoltage grid (SW) Grid overvoltage 93
7001Fault sensor interior temperature fault stops needs service 93
7014Fault boost converter temperature sensor needs service 93
7015Fault sensor interior temperature fault stops needs service 94
7702 fault stops needs service Internal device fault 94
7703Self-diagnosis / SlfDiag > Interference device / DevFlt fault stops needs service Internal device fault 94
7801Fault overvoltage protector warning Surge protector alarm 95
8501DC current sensor C offset Current sensor offset 95
8708Timeout in communication for active power limitation reduced Communication loss 95
8709Timeout in communication for reactive power spec. reduced Communication loss 96
8710 unaffected Communication loss 96
9002Installer code invalid informational Invalid access code 96
9003Grid parameter locked informational Parameter change rejected 96
9007Abort self-test Self-test failure 97
9033Rapid shutdown has been triggered stops Rapid shutdown triggered 97
9034Error in the rapid shutdown system Rapid shutdown failure 97
9035Rapid shutdown performed successfully informational 98
9038Redundant rapid shutdown discharge function not assured needs service Rapid shutdown failure 98

Sunny Central 500CP XT-1000CP XT

CodeShown asClassProductionClearsReportsPage
0103 fault stops by itself Grid overvoltage, High grid impedance 34
0104 stops by itself Grid overvoltage 34
0203 fault stops by itself Grid undervoltage, Grid loss 34
0204 stops by itself Grid undervoltage 34
0205 fault stops by itself Grid synchronization failure, Grid frequency out of range 34
404 fault stops by itself Islanding detected, Grid instability 35
0502 fault stops by itself Grid underfrequency 35
0503 fault stops by itself Grid overfrequency 35
0504 stops by itself Grid underfrequency 35
0505 stops by itself Grid overfrequency 35
0506 stops by itself Islanding detected 35
801 stops Grid loss 35
0802 stops by itself Phase loss 35
1301 Incorrect phase sequence 35
1500 stops by itself Grid voltage out of range 35
3403 DC overvoltage 35
3404 fault DC overvoltage 35
3406 DC overvoltage 35
3501 fault stops Ground fault alarm or trip, Low insulation resistance 36
3502 Ground fault alarm or trip 36
3504 Low insulation resistance 36
3507 Ground fault alarm or trip 36
3510 Low insulation resistance 36
3511 Low insulation resistance 36
3512 Ground fault alarm or trip 36
3515 warning Ground fault alarm or trip 36
3517 informational 36
3520 informational 36
3601 fault stops after a limited number of retries High leakage current, Ground fault alarm or trip 36
3803 stops by itself DC overcurrent 36
4003 String reverse current, Reverse polarity 36
6002 needs service Calibration failure 37
6113 needs service Internal memory error 37
6115 needs service Internal device fault 37
6116 needs service System clock time lost 37
6117 needs service Internal device fault 37
6119 needs service Internal communication failure 37
6120 needs service Internal device fault 37
6121 needs service Internal device fault 37
6122 needs service Internal device fault 37
6128 stops by itself Grid overvoltage 37
6404 fault stops by itself AC overcurrent 37
6405 by itself DC bus overvoltage 37
6410 fault needs service Invalid internal supply voltage 37
6417 fault needs service Invalid internal supply voltage 37
6418 fault needs service Inverter overtemperature 37
6422 fault after a manual reset Internal device fault 37
6423 fault needs service Inverter overtemperature 37
6425 fault needs service Grid synchronization failure 37
6427 fault needs service 37
6440 Transformer seal loss 37
6441 fault needs service 38
6443 fault needs service Internal device fault 38
6447 fault needs service Self-test failure 38
6448 Insulation monitor threshold error 38
6451 needs service AC voltage measurement mismatch 38
6452 needs service AC voltage measurement mismatch 38
6453 needs service Measurement signal error 38
6454 needs service Measurement signal error 38
6455 needs service Measurement signal error 38
6456 needs service 38
6457 needs service Self-test failure 38
6461 Insulation monitor threshold error 38
6471 needs service Self-test failure 38
6472 needs service Self-test failure 38
6486 AC DC power deviation 38
6487 needs service Ground fault alarm or trip 38
6501 fault stops Inverter overtemperature 38
6502 fault stops Inverter overtemperature 38
6508 High ambient temperature 38
6512 stops by itself Inverter undertemperature 38
6605 fault stops needs service Inverter overtemperature 39
7001 fault stops needs service 39
7002 fault stops needs service 39
7004 39
7006 39
7501 39
7502 39
7503 39
7507 Fan fault alarm 39
7510 39
7600 Internal communication failure 39
7601 needs service Internal device fault 39
7602 needs service Internal communication failure 39
7603
7605 after a manual reset Internal communication failure 39
7704 Switching device status fault 39
7706 needs service AC disconnect open 39
7707 needs service Switching device status fault 39
7708 needs service Switching device status fault 39
7709 needs service Switching cycle limit reached 39
7710 needs service Switching cycle limit reached 39
7714 needs service Switching cycle limit reached 40
7801 warning Surge protector alarm 40
7901 needs service String reverse current 40
8701 warning unaffected by itself Invalid power setpoint 40
8702 warning needs service Conflicting power setpoints 40
8703 warning needs service Invalid power setpoint 40
8704 warning needs service Invalid power setpoint 40
9008 needs service Enclosure door open 40
9009 fault stops after a manual reset Emergency stop triggered 40
9013 stops Remote shutdown 40
9019 40

Sunny Island 4548-US / 6048-US

CodeShown asClassProductionClearsReportsPage
E101Waiting mode 205
E102Startup process 205
E103Operation 205
E104Operating on the generator (at external input) informational unaffected 205
E105Operation on utility grid (at external input) informational unaffected 205
E106Feeding-in grid operation (at external input) informational unaffected 205
E107Sleep mode (slave in single-phase systems) informational 206
E108Silent mode on utility grid informational 206
E110Shutdown due to error fault stops Inverter shutdown 206
E115Emergency charge 206
E118Automatic start 206
E119Manual start (transition from standby mode to operation) informational 206
E120Manual stop (transition from operation to standby mode) informational stops 206
E121Start of energy saving mode informational 206
E122End of energy saving mode informational 206
E129External start (remote) informational 206
E130External stop (remote) informational stops Remote shutdown 206
E131Start of automatic frequency synchronization informational 206
E132End of automatic frequency synchronization informational 206
E202(Partial) reset of BMS due to new battery informational 206
E203State change, battery charging algorithm for float charge informational 206
E204State change, battery charging algorithm for boost charge informational 206
E205State change, battery charging algorithm for full charge informational 206
E206State change into silent mode option informational 206
E207State change, battery charging algorithm for equalization charge informational 206
E221Status change battery-preservation mode level 1 informational 206
E222Status change battery-preservation mode level 2 informational 206
E223Status change battery-preservation mode level 3 informational 206
E401 informational 206
E402 informational 206
E403Manual generator start informational 206
E404Manual generator stop informational 207
E405Manual error acknowledgment of generator error informational 207
E406Source of generator request informational 207
E407Current-regulated generator operation initiated informational 207
E408Current-controlled generator operation stopped informational 207
E501Grid request due to SOC (insufficient value) informational 207
E502Release of grid due to SOC (exceeds) informational 207
E503Grid request due to exceeding the power limit informational 207
E504 informational 207
E505Manual grid request informational 207
E506Manual grid release informational 207
E507Feed-in started informational 207
E508Feed-in stopped informational 207
E601Relay 1 off informational 207
E602Relay 1 on informational 207
E603Relay 1 slave 1 off informational 207
E604Relay 1 slave 1 on informational 207
E605Relay 1 slave 2 off informational 207
E606Relay 1 slave 2 on informational 207
E607Relay 1 slave 3 off informational 207
E608Relay 1 slave 3 on informational 207
E609Transfer relay open informational 207
E610Transfer relay closed informational 207
E611Transfer relay on slave 1 open informational 207
E612Transfer relay on slave 1 closed informational 207
E613Transfer relay on slave 2 open informational 207
E614Transfer relay on slave 2 closed informational 208
E615Transfer relay on slave 3 open informational 208
E616Transfer relay on slave 3 closed informational 208
E617Relay 2 open informational 208
E618Relay 2 closed informational 208
E619Relay 2 slave 1 open informational 208
E620Relay 2 slave 1 closed informational 208
E621Relay 2 slave 2 open informational 208
E622Relay 2 slave 2 closed informational 208
E623Relay 2 slave 3 open informational 208
E624Relay 2 slave 3 closed informational 208
E625Digital input OFF (Low) informational 208
E626Digital input ON (High) informational 208
E627Digital input slave 1 to OFF (low) informational 208
E628Digital input slave 1 to ON (high) informational 208
E629Digital input slave 2 to OFF (low) informational 208
E630Digital input slave 2 to ON (high) informational 208
E631Digital input slave 3 to OFF (low) informational 208
E632Digital input slave 3 to ON (high) informational 208
E705Device start 208
E706date, time changed informational 208
E707New system configured in QCG informational 208
E708Part 1 of firmware updated informational 208
E709Part 2 of firmware updated informational 208
E710Cluster firmware updated informational 208
E711MMC/SD memory card inserted informational 208
E712Parameters from MMC/SD memory card loaded informational 208
E851Sunny Island Charger #1 detected informational 208
E852Sunny Island Charger #2 detected informational 208
E853Sunny Island Charger #3 detected informational 209
E854Sunny Island Charger #4 detected informational 209
E901SOC recalibration started informational 209
E902SOC recalibration stopped informational 209
E903Derating started 209
E904Derating stopped 209
E905 stops Battery deep discharge protection 209
F109Transformer overtemperature fault 210
F113Overtemperature heat sink fault Inverter overtemperature 210
F117 fault AC overcurrent 210
F121Inverter overvoltage fault 210
F141Inverter undervoltage fault 210
F158Voltage on output AC1 fault Voltage on AC output 210
F201Measuring range of battery voltage exceeded fault Battery voltage out of range 211
F206Battery overtemperature fault 211
F208Battery overvoltage error fault Battery overvoltage 211
F213Warning low battery voltage fault Battery undervoltage 211
F221 fault Configuration error 211
F314External voltage failure fault Grid loss 211
F605Transfer relay does not open fault 214
F702DSP reset fault 214
F703Timeout during a task fault 214
F704Invalid DSP calibration fault Calibration failure 214
F706 fault 215
F710Autostart meter elapsed (several autostarts in succession) fault 215
F716Measuring range of battery voltage exceeded fault Battery voltage out of range 215
F720 fault 215
F721 fault 215
F731Error in cluster configuration fault Configuration error 215
F732Error in address assignment of cluster devices fault Configuration error 215
F733No message from cluster master (only slave) fault Communication loss 215
F739Internal communication of the master is interrupted fault Internal communication failure 215
F743Internal CAN communication of the master is interrupted fault Internal communication failure 215
F754Communication with Multicluster Box interrupted fault Communication loss 216
F758No output voltage measured from the main cluster fault No output voltage measured 216
F781 fault stops Internal device fault 216
F782Failure of the grid monitoring fault Grid monitoring failure 216
F783Slave does not receive a Syncpuls fault Missing synchronization pulse 216
F801 fault Switching device status fault 217
F806Multicluster Box settings do not match software settings. fault Configuration error 217
F809Error Q10 contactor (load shedding) fault Switching device status fault 217
F810 fault Invalid internal supply voltage 217
F811 fault Invalid internal supply voltage 217
F816Error Q7 contactor fault Switching device status fault 217
F817Error Q9 contactor fault Switching device status fault 217
F818 fault stops Phase loss 217
F890Interference at external measurement point of Multicluster Box fault Measurement signal error 218
F891 fault Measurement signal error 218
F892 fault Measurement signal error 218
F893 fault Measurement signal error 218
F920Error message via SiCom: General fault 218
F921Error message via SiCom: Battery overvoltage fault Battery overvoltage 218
F922Error message via SiCom: Battery undervoltage fault Battery undervoltage 218
F923Error message via SiCom: Battery overtemperature fault High battery temperature 218
F924Error message via SiCom: Battery undertemperature fault Low battery temperature 218
F925 fault High battery temperature 218
F926 fault Low battery temperature 218
F927 fault Excessive battery charging current 218
F928 fault Excessive battery charging current 218
F929Error message via SiCom: Error in the battery fault 218
F930Error message via SiCom: Short circuit fault Short circuit 218
F931 fault Battery management system error 218
F932 fault Battery cell charge imbalance 219
F935Error message via SiCom: Error in the generator fault 219
F952Time for external battery management exceeded fault External battery management timeout 219
W110Overtemperature transformer slave 1 warning Inverter overtemperature 210
W111Overtemperature transformer slave 2 warning Inverter overtemperature 210
W112Overtemperature transformer slave 3 warning Inverter overtemperature 210
W114Overtemperature heat sink slave 1 warning Inverter overtemperature 210
W115Overtemperature heat sink slave 2 warning Inverter overtemperature 210
W116Overtemperature heat sink slave 3 warning Inverter overtemperature 210
W118 warning AC overcurrent 210
W119 warning AC overcurrent 210
W120 warning AC overcurrent 210
W122Inverter overvoltage slave 1 warning Inverter overvoltage 210
W123Inverter overvoltage slave 2 warning Inverter overvoltage 210
W124Inverter overvoltage slave 3 warning Inverter overvoltage 210
W137Derating due to temperature (heat sink or transformer) warning reduced Inverter power derating, Inverter overtemperature 210
W138 warning reduced Inverter power derating, Inverter overtemperature 210
W139 warning reduced Inverter power derating, Inverter overtemperature 210
W140 warning reduced Inverter power derating, Inverter overtemperature 210
W142Inverter undervoltage slave 1 warning Inverter undervoltage 210
W143Inverter undervoltage slave 2 warning Inverter undervoltage 210
W144Inverter undervoltage slave 3 warning Inverter undervoltage 210
W159Voltage on output AC1 slave 1 warning Voltage on AC output 210
W160Voltage on output AC1 slave 2 warning Voltage on AC output 210
W161Voltage on output AC1 slave 3 warning Voltage on AC output 210
W202 warning Battery voltage out of range 211
W203 warning Battery voltage out of range 211
W204 warning Battery voltage out of range 211
W209Battery overvoltage error warning Battery overvoltage 211
W210Battery overvoltage warning warning Battery overvoltage 211
W211Low battery temperature warning warning Low battery temperature 211
W212High battery temperature warning warning High battery temperature 211
W220Warning SOH < 70% warning Low battery state of health 211
W309Relay protection warning 211
W310Relay protection slave 1 warning 211
W311Relay protection slave 2 warning 211
W312Relay protection slave 3 warning 211
W315 warning Grid undervoltage 211
W316 warning Grid undervoltage 211
W317 warning Grid undervoltage 211
W318 warning Grid undervoltage 211
W319 warning Grid overvoltage 211
W320 warning Grid overvoltage 212
W321 warning stops Grid overvoltage 212
W322 warning stops Grid overvoltage 212
W323 warning stops Grid underfrequency 212
W324 warning stops Grid underfrequency 212
W325 warning stops Grid underfrequency 212
W326 warning stops Grid underfrequency 212
W327 warning stops Grid overfrequency 212
W328 warning stops Grid overfrequency 212
W329 warning stops Grid overfrequency 212
W330 warning stops Grid overfrequency 212
W331Disconnection from utility grid/generator due to islanding warning stops Islanding detected 212
W332 warning stops Islanding detected 212
W333 warning stops Islanding detected 212
W334 warning stops Islanding detected 212
W335 warning stops Grid voltage out of range 212
W336 warning stops Grid voltage out of range 212
W337 warning stops Grid voltage out of range 212
W338 warning stops Grid voltage out of range 212
W339 warning stops Grid overvoltage 212
W340 warning stops Grid overvoltage 213
W341 warning stops Grid overvoltage 213
W342 warning stops Grid overvoltage 213
W343 warning stops 213
W344 warning stops 213
W345 warning 213
W346 warning 213
W347Disconnection from external source due to excessive load warning Inverter overload 213
W348 warning Inverter overload 213
W349 warning Inverter overload 213
W350 warning Inverter overload 213
W351 warning External short circuit 213
W352 warning External short circuit 213
W353 warning External short circuit 213
W354 warning External short circuit 213
W377 warning AC overcurrent 213
W378 warning AC overcurrent 213
W379 warning AC overcurrent 213
W380 warning AC overcurrent 213
W401Reverse power protection (generator) warning Reverse power flow 214
W402 warning Generator management locked 214
W501Grid reverse current prevented (quick grid disconnection) warning stops Reverse power flow 214
W502 warning stops Reverse power flow 214
W503 warning stops Reverse power flow 214
W504 warning stops Reverse power flow 214
W505 warning AC overcurrent 214
W506 warning AC overcurrent 214
W507 warning AC overcurrent 214
W508 warning AC overcurrent 214
W606Transfer relay does not open slave 1 warning 214
W607Transfer relay does not open slave 2 warning 214
W608Transfer relay does not open slave 3 warning 214
W705Watchdog DSP has been tripped warning 214
W707 warning 215
W708 warning 215
W709 warning 215
W713Watchdog has been tripped warning Internal device fault 215
W717 warning Battery voltage out of range 215
W718 warning Battery voltage out of range 215
W719 warning Battery voltage out of range 215
W722Short circuit on battery temperature sensor warning 215
W723Cable break on battery temperature sensor warning 215
W724Autostart meter slave 1 elapsed warning Automatic restart limit reached 215
W725Autostart meter slave 2 elapsed warning Automatic restart limit reached 215
W726Autostart meter slave 3 elapsed warning Automatic restart limit reached 215
W734No message from cluster slave 1 warning Communication loss 215
W735No message from cluster slave 2 warning Communication loss 215
W736No message from cluster slave 3 warning Communication loss 215
W738Synchronization not successful warning 215
W740Internal device communication of slave 1 interrupted warning Internal communication failure 215
W741Internal device communication of slave 2 interrupted warning Internal communication failure 215
W742Internal device communication of slave 3 interrupted warning Internal communication failure 215
W744Internal CAN communication of slave 1 is interrupted warning Internal communication failure 216
W745Internal CAN communication of slave 2 is interrupted warning Internal communication failure 216
W746Internal CAN communication of slave 3 is interrupted warning Internal communication failure 216
W747 warning 216
W748 warning 216
W749 warning 216
W750 warning 216
W751 warning 216
W752 warning 216
W753Invalid system time warning Inaccurate clock time 216
W755Battery-preservation mode 1 (LBM) warning Battery protection mode active 216
W756Battery-preservation mode 2 (LBM) warning Battery protection mode active 216
W757Battery-preservation mode 3 (LBM) warning Battery protection mode active 216
W759 warning No output voltage measured 216
W760 warning No output voltage measured 216
W761 warning No output voltage measured 216
W784Slave does not receive a Syncpuls Slave 1 warning Missing synchronization pulse 216
W785Slave does not receive a Syncpuls Slave 2 warning Missing synchronization pulse 216
W786Slave does not receive a Syncpuls Slave 3 warning Missing synchronization pulse 216
W791DSP reset detected on slave 1 warning Signal processor reset 216
W792DSP reset detected on slave 2 warning Signal processor reset 216
W793DSP reset detected on slave 3 warning Signal processor reset 216
W797Failure of the grid monitoring slave 1 warning Grid monitoring failure 216
W798Failure of the grid monitoring slave 2 warning Grid monitoring failure 216
W799Failure of the grid monitoring slave 3 warning Grid monitoring failure 216
W804Grid operation not possible warning Operation inhibited 217
W805Generator operation not possible warning Operation inhibited 217
W807No valid line voltage for requested grid operation warning Grid voltage out of range 217
W808Error Q4 contactor warning Switching device status fault 217
W815Error Q5 contactor warning Switching device status fault 217
W824Error Q4 contactor warning Switching device status fault 217
W851 warning Reverse polarity, External short circuit 217
W852Battery overvoltage Sunny Island Charger 1 warning Battery overvoltage 217
W853Overvoltage PV array Sunny Island Charger 1 warning DC overvoltage 217
W854 warning Abnormal PV input 217
W855 warning Abnormal temperature reading 217
W856Overtemperature Sunny Island Charger 1 warning Charge controller overtemperature 217
W857 warning Communication loss 217
W861 warning Reverse polarity, External short circuit 217
W862Battery overvoltage Sunny Island Charger 2 warning Battery overvoltage 217
W863Overvoltage PV array Sunny Island Charger 2 warning DC overvoltage 217
W864 warning Abnormal PV input 217
W865 warning Abnormal temperature reading 217
W866Overtemperature Sunny Island Charger 2 warning Charge controller overtemperature 217
W867 warning Communication loss 217
W871 warning Reverse polarity, External short circuit 217
W872Battery overvoltage Sunny Island Charger 3 warning Battery overvoltage 217
W873Overvoltage PV array Sunny Island Charger 3 warning DC overvoltage 217
W874 warning Abnormal PV input 218
W875 warning Abnormal temperature reading 218
W876Overtemperature Sunny Island Charger 3 warning Charge controller overtemperature 218
W877 warning Communication loss 218
W881 warning Reverse polarity 218
W882Battery overvoltage Sunny Island Charger 4 warning Battery overvoltage 218
W883Overvoltage PV array Sunny Island Charger 4 warning DC overvoltage 218
W884 warning Abnormal PV input 218
W885 warning Abnormal temperature reading 218
W886Overtemperature Sunny Island Charger 4 warning Charge controller overtemperature 218
W887 warning Communication loss 218
W915DSP failure warning 218
W936Warning via SiCom: General warning 219
W937Warning via SiCom: Battery overvoltage warning Battery overvoltage 219
W938Warning via SiCom: Battery undervoltage warning Battery undervoltage 219
W939Warning via SiCom: Battery overtemperature warning High battery temperature 219
W940Warning via SiCom: Battery undertemperature warning Low battery temperature 219
W941Warning via SiCom: Battery overtemperature in charge mode warning High battery temperature 219
W942Warning via SiCom: Battery undertemperature in charge mode warning Low battery temperature 219
W943Warning via SiCom: battery charging current too high warning Excessive battery charging current 219
W944 warning Excessive battery charging current 219
W945Warning via SiCom: error in the battery warning Battery error reported 219
W946Warning via SiCom: short circuit warning Short circuit 219
W947Warning via SiCom: internal error in battery management warning Battery management system error 219
W948 warning Battery cell charge imbalance 219
W951Warning via SiCom: Generator warning 219
W953Time for external battery management exceeded warning External battery management timeout 219

Codes are sorted by vendor prefix and number. Each row links to the code's record; concepts link to their reading rule.