Solar Lattice

Fault codes › SMA › Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)

SMA SB-US-41 1302

Code
1302
Page
55
ID
fc:sma-sb-us-41-1302
IRI
https://solarlattice.org/kb/fc/sma-sb-us-41-1302
Status
active
Also known as
1302, SMA 1302
Category
Inverters
Class fault drafted · lead
Production stops verified · fact
Clears not stated

Decoded

Reports grid loss, phase loss; look at AC cable; confirm with grid voltage measurement; do: AC connection check, grid settings check, grounding conductor check.

What can be behind Grid loss

Failure modes that present as the reported condition, and the tests that tell them apart.

What can be behind Phase loss

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

Canadian Solar
Canadian Solar 125K-T600GL02 NO-GRID, Canadian Solar 125KTL-GS-E NO-GRID, Canadian Solar 185-255K NO-GRID, Canadian Solar 23-28KTL-CT GridF.OutLim, Canadian Solar 25-40K-T480GL01 NO-GRID, Canadian Solar 25-40KTL-GS-FL NO-GRID, Canadian Solar 50-66K-T480GL01 NO-GRID, Canadian Solar 50-66KTL-GS-FL NO-GRID, Canadian Solar 75-100K-T480GL02 NO-GRID
Fronius
Fronius Galvo 107, Fronius Primo 107, Fronius Symo 107
Huawei
Huawei SUN2000-100KTL-USH0 2032, Huawei SUN2000-25-30KTL-US 301, Huawei SUN2000-45KTL-US-HV-D0 301
KACO new energy
KACO new energy blueplanet TL3 73
SMA
SMA SB-US-40 1302, SMA SB-US-40 202-206, SMA SB-US-41 202, SMA SB-US-41 0203, SMA SB-US-41 206, SMA SBSE-US-50 1302, SMA SBSE-US-50 202, SMA SBSE-US-50 0203, SMA SBSE-US-50 206, SMA PEAK3-US 1302, SMA CORE1-US 801, SMA STP-TL-US 1302, SMA STP-TL-US 202-203, SMA STP-X-US 1302, SMA SC-CP-XT 0203, SMA SC-CP-XT 801, SMA SC-CP-XT 0802, SMA SI-US F314, SMA SI-US F818
Solis
Solis 1P-4G-US NO-GRID, Solis 3P-5G-US NO-GRID, Solis RHI-1P-HV NO-GRID, Solis S5-GC NO-GRID, Solis S6-EH1P NO-GRID, Solis S6-EH2P NO-GRID, Solis S6-EH3P30-60K NO-GRID, Solis S6-EH3P75-150K NO-GRID, Solis S6-GC NO-GRID, Solis S6-GU NO-GRID
Sungrow
Sungrow SG-CX-US 010, Sungrow SG200HX 010, Sungrow SG250HX 10, Sungrow SG350HX 010
Yaskawa Solectria
Yaskawa Solectria SGI-XTM AC Islanding, Yaskawa Solectria SGI-XTM Open Phase, Yaskawa Solectria SGI-XTM Wait for Grid, Yaskawa Solectria XGI-1500-1MW WARN-4, Yaskawa Solectria XGI-1500-DCG WARN-4, Yaskawa Solectria XGI-1500 WARN-4

Same code in other families

Claims

defined_in

c1 drafted · lead SBxx-US-1XP-41-BA-en-12

reports

c2 drafted · lead Grid loss

c3 drafted · lead Phase loss

affects

c4 drafted · lead AC cable

detected_by

c5 drafted · lead Grid voltage measurement

review note: support check: partial - The passages say the grid monitor detects the unconnected conductors and list AC voltage measurements as corrective steps; they don't…

mitigated_by

c6 drafted · lead AC connection check

c7 drafted · lead Grid settings check

c8 drafted · lead Grounding conductor check

has_event_class

c9 drafted · lead Fault (device stops or needs intervention)

has_production_effect

c10 verified · fact Trip (production stops)

verified by: review-workflowverified on: 2026-10-23

applies_to

c11 drafted · lead Sunny Boy 3.0-7.7-US-41 proposed

Data