Grid settings check
For a frequency fault, read the measured frequency on the inverter LCD. If the value is within the limit, restart the inverter. A similar Solectria procedure blames out-of-range grid frequency or loose AC connections. It says to watch for 10 minutes to see if the alarm clears by itself, check the frequency and AC wiring, and contact customer service if the error stays. A wrong grid standard or country data set can make the inverter run improperly, damage it or stop it from running at all. On SMA units it can look like the inverter is waiting for grid voltage. Only certified personnel should set the grid standard, and only to a configuration approved for the location. Settings meant for grid operators should not be changed unless you are specifically told to. To verify the programmed grid protection settings, open the inverter's view menu and compare each setpoint with the required values. O&M guidelines say plant control settings should be monitored at the inverter and grid injection levels. They list a yearly check of inverter parameters as a minimum requirement.
<!-- review notes
- sentence 3: support check: partial - The warning covers improper operation, damage or not operating, and the waiting-for-grid-voltage message lists a misconfigured country data set as a cause. The passages never name SMA or say the wrong standard makes the inverter look like it is waiting for grid voltage, though that is implied.
- sentence 5: support check: partial - The passage gives the path Maintenance → Grid Protection → View and says to verify setpoints against Table 1. It does not say 'view menu' exactly, and the required values are in a table the passage does not include.
- sentence 6: support check: partial - Monitoring control settings at inverter and grid injection level is stated. The annex lists 'Check parameters' for inverters as a yearly minimum requirement, but the passage does not tie that check to control settings. Calling it a guideline 'listing' this is a reasonable reading. -->
Referenced by
- CPS SCA36KTL GridF.OutLim
mitigated_byc4 - CPS SCA36KTL GridV.OutLim
mitigated_byc4 - CPS SCA50-60KTL GridF.OutLim
mitigated_byc4 - CPS SCA50-60KTL GridV.OutLim
mitigated_byc4 - Huawei SUN2000-100KTL-USH0 2034
mitigated_byc6 - Huawei SUN2000-100KTL-USH0 2037
mitigated_byc6 - Huawei SUN2000-25-30KTL-US 301
mitigated_byc10 - Huawei SUN2000-25-30KTL-US 305
mitigated_byc8 - Huawei SUN2000-45KTL-US-HV-D0 301
mitigated_byc10 - Huawei SUN2000-45KTL-US-HV-D0 305
mitigated_byc8 - KACO new energy blueplanet TL3 108
mitigated_byc6 - KACO new energy blueplanet TL3 111
mitigated_byc5 - KACO new energy blueplanet TL3 112
mitigated_byc5 - KACO new energy blueplanet TL3 113
mitigated_byc5 - KACO new energy blueplanet TL3 17
mitigated_byc5 - KACO new energy blueplanet TL3 41
mitigated_byc6 - KACO new energy blueplanet TL3 42
mitigated_byc6 - KACO new energy blueplanet TL3 43
mitigated_byc6 - KACO new energy blueplanet TL3 47
mitigated_byc7 - KACO new energy blueplanet TL3 48
mitigated_byc5 - KACO new energy blueplanet TL3 49
mitigated_byc5 - KACO new energy blueplanet TL3 50
mitigated_byc5 - SMA SB-US-40 101-105
mitigated_byc7 - SMA SB-US-40 1302
mitigated_byc7 - SMA SB-US-40 1501
mitigated_byc4 - SMA SB-US-40 202-206
mitigated_byc10 - SMA SB-US-41 1302
mitigated_byc7 - SMA SB-US-41 1501
mitigated_byc4 - SMA SB-US-41 202
mitigated_byc10 - SMA SB-US-41 0203
mitigated_byc7 - SMA SB-US-41 0205
mitigated_byc7 - SMA SB-US-41 206
mitigated_byc10 - SMA SBSE-US-50 1302
mitigated_byc7 - SMA SBSE-US-50 1501
mitigated_byc4 - SMA SBSE-US-50 202
mitigated_byc10 - SMA SBSE-US-50 0203
mitigated_byc7 - SMA SBSE-US-50 206
mitigated_byc10 - SMA SBSE-US-50 9007
mitigated_byc4 - SMA PEAK3-US 1302
mitigated_byc7 - SMA PEAK3-US 1501
mitigated_byc4 - SMA PEAK3-US 9007
mitigated_byc4 - SMA CORE1-US 801
mitigated_byc8 - SMA CORE1-US 9007
mitigated_byc6 - SMA STP-TL-US 1302
mitigated_byc7 - SMA STP-TL-US 1501
mitigated_byc4 - SMA STP-X-US 1302
mitigated_byc7 - SMA STP-X-US 1501
mitigated_byc4 - SMA STP-X-US 9007
mitigated_byc4 - SMA SC-CP-XT 0203
mitigated_byc7 - SMA SC-CP-XT 0205
mitigated_byc7 - SMA SC-CP-XT 801
mitigated_byc6 - Solis 1P-4G-US NO-GRID
mitigated_byc8 - Solis 1P-4G-US OV-G-F
mitigated_byc6 - Solis 1P-4G-US UN-G-F
mitigated_byc5 - Solis 1P-4G-US UN-G-V
mitigated_byc7 - Solis 3P-5G-US NO-GRID
mitigated_byc7 - Solis RHI-1P-HV NO-GRID
mitigated_byc7 - Solis RHI-1P-HV OV-G-V01/02/03/04/05
mitigated_byc5 - Solis S5-GC NO-GRID
mitigated_byc7 - Solis S5-GC OV-G-F
mitigated_byc5 - Solis S5-GC UN-G-V
mitigated_byc6 - Solis S6-EH1P NO-GRID
mitigated_byc7 - Solis S6-EH1P OV-G-V01/02/03/04/05
mitigated_byc5 - Solis S6-EH2P NO-GRID
mitigated_byc7 - Solis S6-EH3P30-60K NO-GRID
mitigated_byc8 - Solis S6-EH3P75-150K NO-GRID
mitigated_byc7 - Solis S6-GC NO-GRID
mitigated_byc8 - Solis S6-GC OV-G-F
mitigated_byc6 - Solis S6-GC UN-G-F
mitigated_byc4 - Solis S6-GC UN-G-V
mitigated_byc7 - Solis S6-GU NO-GRID
mitigated_byc7 - Solis S6-GU OV-G-F
mitigated_byc5 - Solis S6-GU UN-G-F
mitigated_byc4 - Solis S6-GU UN-G-V
mitigated_byc6 - Sungrow SG-CX-US 015
mitigated_byc9 - Sungrow SG-CX-US 002
mitigated_byc10 - Sungrow SG-CX-US 004
mitigated_byc10 - Sungrow SG-CX-US 005
mitigated_byc10 - Sungrow SG-CX-US 009
mitigated_byc6 - Sungrow SG200HX 015
mitigated_byc8 - Sungrow SG200HX 002
mitigated_byc9 - Sungrow SG200HX 004
mitigated_byc9 - Sungrow SG200HX 005
mitigated_byc9 - Sungrow SG200HX 009
mitigated_byc5 - Sungrow SG250HX 14
mitigated_byc7 - Sungrow SG250HX 15
mitigated_byc7 - Sungrow SG250HX 2
mitigated_byc7 - Sungrow SG250HX 3
mitigated_byc7 - Sungrow SG250HX 4
mitigated_byc7 - Sungrow SG250HX 5
mitigated_byc7 - Sungrow SG250HX 9
mitigated_byc5 - Sungrow SG350HX 015
mitigated_byc8 - Sungrow SG350HX 002
mitigated_byc9 - Sungrow SG350HX 004
mitigated_byc9 - Sungrow SG350HX 005
mitigated_byc9 - Sungrow SG350HX 009
mitigated_byc5 - Incorrect or unset grid code
mitigated_byc6