KACO new energy blueplanet TL3 49

Code
49
Shown as
Grid failure overfrequency
Page
103
ID
fc:kaco-blueplanet-87-165-tl3-49
IRI
https://solarlattice.org/kb/fc/kaco-blueplanet-87-165-tl3-49
Status
active
Also known as
49, KACO new energy 49, Grid failure overfrequency
Category
Inverters
Class not stated
Production not stated
Clears not stated

Decoded

Reports grid overfrequency; confirm with inverter settings review, grid voltage measurement; do: grid settings check, AC connection check.

What can be behind Grid overfrequency

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL W006, ABB / FIMER PVS-60-TL CODE:01, ABB / FIMER PVS-60-TL W006, ABB / FIMER TRIO-20.0-27.6-TL CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS W006, ABB / FIMER UNO-DM-6.0-PLUS CODE:01, ABB / FIMER UNO-DM-6.0-PLUS W006
Canadian Solar
Canadian Solar 125K-T600GL02 OV-G-F, Canadian Solar 125KTL-GS-E OV-G-F, Canadian Solar 185-255K OV-G-F01/02, Canadian Solar 25-40K-T480GL01 OV-G-F, Canadian Solar 25-40KTL-GS-FL OV-G-F, Canadian Solar 50-66K-T480GL01 OV-G-F, Canadian Solar 50-66KTL-GS-FL OV-G-F, Canadian Solar 75-100K-T480GL02 OV-G-F
Fronius
Fronius Galvo 105, Fronius Galvo 560, Fronius Primo 105, Fronius Primo 560, Fronius Symo 105, Fronius Symo 560
Huawei
Huawei SUN2000-100KTL-USH0 2036, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
SMA
SMA SBSE-US-50 507, SMA PEAK3-US 0503, SMA PEAK3-US 507, SMA STP-X-US 507, SMA SC-CP-XT 0503, SMA SC-CP-XT 0505, SMA SI-US W327, SMA SI-US W328, SMA SI-US W329, SMA SI-US W330
Schneider Electric
Schneider Electric CL125 008
Solis
Solis 1P-4G-US OV-G-F, Solis 3P-5G-US OV-G-F01/02, Solis RHI-1P-HV OV-G-F01/02, Solis S5-GC OV-G-F, Solis S6-EH1P OV-G-F01/02, Solis S6-EH2P OV-G-F01, Solis S6-EH2P OV-G-F02, Solis S6-EH3P30-60K OV-G-F01, Solis S6-EH3P30-60K OV-G-F02, Solis S6-EH3P75-150K OV-G-F01, Solis S6-EH3P75-150K OV-G-F02, Solis S6-GC OV-G-F, Solis S6-GU OV-G-F
Sungrow
Sungrow SG-CX-US 008, Sungrow SG200HX 008, Sungrow SG250HX 8, Sungrow SG350HX 008
Yaskawa Solectria
Yaskawa Solectria SGI-XTM Fac High, Yaskawa Solectria XGI-1500-1MW WARN-7, Yaskawa Solectria XGI-1500-1MW WARN-8, Yaskawa Solectria XGI-1500-DCG WARN-7, Yaskawa Solectria XGI-1500-DCG WARN-8, Yaskawa Solectria XGI-1500 WARN-7, Yaskawa Solectria XGI-1500 WARN-8

Claims

defined_in

c1 drafted · lead KACO blueplanet 87.0-165 TL3 Operating Manual EN 2020-10 (Siemens-hosted copy)

reports

c2 drafted · lead Grid overfrequency

Taken from the label; the row's description says below the limit, which conflicts with the label.

detected_by

c3 drafted · lead Inverter settings review

Uses the code 48 action that the row points to.

c4 drafted · lead Grid voltage measurement

mitigated_by

c5 drafted · lead Grid settings check

c6 drafted · lead AC connection check

applies_to

c7 drafted · lead KACO blueplanet 87.0-165 TL3

Data