ABB / FIMER PVS-166-175-TL W006

Code
W006
Shown as
Grid OF
Vendor severity
Warning
Page
137
ID
fc:abb-pvs-166-175-tl-us-w6
IRI
https://solarlattice.org/kb/fc/abb-pvs-166-175-tl-us-w6
Status
active
Also known as
W006, w6, ABB / FIMER W006, Grid OF
Category
Inverters
Class warning drafted · lead
Production not stated
Clears not stated

Decoded

Reports grid overfrequency; confirm with grid frequency measurement; do: contact manufacturer service.

What can be behind Grid overfrequency

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-60-TL CODE:01, ABB / FIMER PVS-60-TL W006, ABB / FIMER TRIO-20.0-27.6-TL CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS W006, ABB / FIMER UNO-DM-6.0-PLUS CODE:01, ABB / FIMER UNO-DM-6.0-PLUS W006
Canadian Solar
Canadian Solar 125K-T600GL02 OV-G-F, Canadian Solar 125KTL-GS-E OV-G-F, Canadian Solar 185-255K OV-G-F01/02, Canadian Solar 25-40K-T480GL01 OV-G-F, Canadian Solar 25-40KTL-GS-FL OV-G-F, Canadian Solar 50-66K-T480GL01 OV-G-F, Canadian Solar 50-66KTL-GS-FL OV-G-F, Canadian Solar 75-100K-T480GL02 OV-G-F
Fronius
Fronius Galvo 105, Fronius Galvo 560, Fronius Primo 105, Fronius Primo 560, Fronius Symo 105, Fronius Symo 560
Huawei
Huawei SUN2000-100KTL-USH0 2036, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
KACO new energy
KACO new energy blueplanet TL3 49
SMA
SMA SBSE-US-50 507, SMA PEAK3-US 0503, SMA PEAK3-US 507, SMA STP-X-US 507, SMA SC-CP-XT 0503, SMA SC-CP-XT 0505, SMA SI-US W327, SMA SI-US W328, SMA SI-US W329, SMA SI-US W330
Schneider Electric
Schneider Electric CL125 008
Solis
Solis 1P-4G-US OV-G-F, Solis 3P-5G-US OV-G-F01/02, Solis RHI-1P-HV OV-G-F01/02, Solis S5-GC OV-G-F, Solis S6-EH1P OV-G-F01/02, Solis S6-EH2P OV-G-F01, Solis S6-EH2P OV-G-F02, Solis S6-EH3P30-60K OV-G-F01, Solis S6-EH3P30-60K OV-G-F02, Solis S6-EH3P75-150K OV-G-F01, Solis S6-EH3P75-150K OV-G-F02, Solis S6-GC OV-G-F, Solis S6-GU OV-G-F
Sungrow
Sungrow SG-CX-US 008, Sungrow SG200HX 008, Sungrow SG250HX 8, Sungrow SG350HX 008
Yaskawa Solectria
Yaskawa Solectria SGI-XTM Fac High, Yaskawa Solectria XGI-1500-1MW WARN-7, Yaskawa Solectria XGI-1500-1MW WARN-8, Yaskawa Solectria XGI-1500-DCG WARN-7, Yaskawa Solectria XGI-1500-DCG WARN-8, Yaskawa Solectria XGI-1500 WARN-7, Yaskawa Solectria XGI-1500 WARN-8

Same code in other families

Claims

defined_in

c1 drafted · lead FIMER PVS-166-175-TL-US A.2 Product Manual RevE

has_event_class

c2 drafted · lead Warning (device continues, a condition is flagged)

from the code prefix

reports

c3 verified · fact Grid overfrequency

verified by: review-workflowverified on: 2026-10-23

detected_by

c4 drafted · lead Grid frequency measurement

mitigated_by

c5 drafted · lead Contact manufacturer service

Only if frequency is back within limits yet alarm continues

applies_to

c6 drafted · lead FIMER PVS-166/175-TL-US string inverter

Data