Product
FIMER PVS-166/175-TL-US string inverter
- ID
prod:abb-pvs-166-175-tl-us
- IRI
https://solarlattice.org/kb/prod/abb-pvs-166-175-tl-us
- Status
- active
- Also known as
- PVS-166-TL-US, PVS-175-TL-US, PVS-166-175-TL-US, PVS-166/175-TL-US
- Category
- Inverters
- Make
- abb
- Product level
- family
The FIMER PVS-166/175-TL-US is a three-phase string inverter family made up of the PVS-166-TL US and PVS-175-TL US models. At unity power factor and 40°C, the PVS-166-TL US is rated 166 500 W of AC output and the PVS-175-TL US 175 000 W. Both connect to an 800 V rated AC grid. Maximum efficiency is 98.6 percent. Current is monitored per MPPT, not per individual string. For communication it uses SunSpec-compliant Modbus RTU and Modbus TCP. Inverter parameters can be upgraded remotely over Ethernet or WLAN using SunSpec Modbus. Its grid support functions are voltage and frequency ride-through with trip limits, fixed power factor, fixed reactive power, power factor as a function of output power, and Volt/VAr control. Reactive power control is disabled by default, so the inverter runs at unity power factor. To change grid settings in the internal webserver, you need a Wi-Fi connection to the inverter.
<!-- review notes
- sentence 1: support check: partial - The two models are evidenced, but 'three-phase' and 'string inverter' are not stated in the passages.
- sentence 1: review: partial - The passages show the two models PVS-166-TL US and PVS-175-TL US, but they never say it is a three-phase string inverter.
-->
Claims
manufactured_by
c1 drafted · lead
FIMER proposed
review note: support check: partial - The evidence is only a manual title naming FIMER and the product; it implies but does not state manufacturer.
rated_power
c2 drafted · lead
nominal 175000 W
Conditions: PVS-175-TL US model, rated AC power at cosφ=1 and 40°C
nominal_voltage
c3 drafted · lead
nominal 800 V
Conditions: Rated AC grid voltage, both models
efficiency
c4 drafted · lead
nominal 98.6 PERCENT
Conditions: Maximum (peak) efficiency
uses_protocol
c5 drafted · lead
Modbus RTU
c6 drafted · lead
Modbus TCP
c7 drafted · lead
SunSpec Modbus
Modbus implementation stated as SunSpec compliant; also used for remote parameter upgrade
c8 drafted · lead
Ethernet
Remote inverter parameter upgrade via Ethernet/WLAN
c9 drafted · lead
Wi-Fi
Wi-Fi connection required to change grid settings through the internal webserver
implements
c10 drafted · lead
String monitoring
Current sensing at MPPT level rather than per string
c11 drafted · lead
Voltage ride-through
c12 verified · fact
Frequency ride-through
verified by: review-workflowverified on: 2026-10-24
c13 drafted · lead
Voltage trip
Disconnects from grid after programmed delay on abnormal voltage
c14 verified · fact
Frequency trip
Disconnects after programmed delay on frequency excursion
verified by: review-workflowverified on: 2026-10-24
c15 drafted · lead
Constant power factor mode
Cosφ set mode; default reactive power setting is disabled (unity power factor)
c16 drafted · lead
Constant reactive power mode
Q Set mode
c17 drafted · lead
Watt-power factor
Cosφ(P) with a 4-point curve adjustable via webserver
c18 drafted · lead
Volt-VAr
Q(V) with a 4-point curve adjustable via webserver