fixed power factor, cos phi fixed, PF mode, DFPF, Fixed PF, Fixed Power Factor mode
Category
Grid support
Function kind
grid-support
Constant power factor mode makes the inverter run at a fixed power factor, so its reactive power follows its active output at a set ratio. In FIMER Aurora Manager LITE, you pick cos-phi fixed as the reactive power regulation mode, enter the over- or under-excited value and confirm with SET. CPS SCH125KTL-AIO, SCH200K/SCH250K-T, SCA25KTL-DO and CSI 23/28KTL-CT inverters list power factor adjustable to plus or minus 0.8. The FIMER PVS-166 adjusts to 0.75 lead or lag, the PVS-175 to 0.8, and the UNO-DM-3.3/3.8-PLUS to plus or minus 0.8.