Solar Lattice

Product

Sungrow SG200HX-US

ID
prod:sungrow-sg200hx
IRI
https://solarlattice.org/kb/prod/sungrow-sg200hx
Status
active
Also known as
SG200HX, SG200HX-US, PV Grid-Connected Inverter
Category
Inverters
Make
sungrow
Product level
family
Model number
SG200HX-US

The Sungrow SG200HX-US is a transformerless, three-phase, grid-connected PV string inverter. It has 12 PV inputs rated at 40 A each, a full-power MPP voltage range of 850 V to 1300 V at 40 °C, and an AC voltage range of 528 V to 660 V. Its maximum efficiency is 98.9 % and its CEC efficiency is 98.5 %. Harmonic distortion is below 3 % at nominal power, and DC current injection is below 0.5 % of rated current. Built-in protections include DC reverse connection protection, AC short-circuit protection, leakage current protection, grid and ground fault monitoring, PV string current monitoring and Type II surge protection on both the DC and AC sides. It can supply reactive power at night and has an adjustable power factor. AFCI and anti-PID with PID recovery are optional extras. The inverter has a DC switch but no AC switch, so a separate AC disconnect has to be provided. It communicates over RS485 using Modbus and SunSpec, and it has LED indicators plus Bluetooth for setup through an app.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Sungrow proposed

review note: support check: partial - Passage mentions SUNGROW warranty but doesn't explicitly state SG200HX-US is made by Sungrow (only implied via document title elsewhere).

instance_of

c2 drafted · lead Inverter

efficiency

c3 drafted · lead nominal 98.9 PERCENT

Conditions: maximum efficiency

review note: possible conflict with c4 (same source; check the conditions)

c4 drafted · lead nominal 98.5 PERCENT

Conditions: CEC weighted efficiency

review note: possible conflict with c3 (same source; check the conditions)

mppt_voltage_range

c5 drafted · lead 850–1300 V

Conditions: full-power MPP voltage range at 40 °C

max_input_current

c6 drafted · lead nominal 40 A

Conditions: maximum PV input current per input, listed as 12 x 40 A

uses_protocol

c7 drafted · lead RS-485

c8 drafted · lead Modbus

c9 verified · fact SunSpec information models

verified by: review-workflowverified on: 2026-10-24

c10 drafted · lead Bluetooth

Bluetooth with app as display/interface alongside LEDs

certified_to

c11 drafted · lead UL 1741 proposed

review note: support check: partial - UL1741 is listed under compliance, but 'certified' is not stated explicitly.

c12 drafted · lead UL 1741 SA proposed

review note: support check: partial - UL1741 SA/SB listed as compliance; certification not explicit.

c13 drafted · lead UL 1741 SB proposed

review note: support check: partial - UL1741 SA/SB listed as compliance; certification not explicit.

c14 drafted · lead UL 62109-1 proposed

review note: support check: partial - UL62109-1 listed as compliance; certification not explicit.; review: partial - UL62109-1 appears in the Compliance row, but the passage claims compliance, not certification.

c15 verified · fact IEEE 1547-2018 proposed

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - IEEE1547-2018 listed as compliance; certification not explicit.

c16 drafted · lead IEEE 1547.1-2020 proposed

review note: support check: partial - IEEE1547.1-2020 listed as compliance; certification not explicit.

c17 drafted · lead CA Rule 21 proposed

review note: support check: partial - California Rule21 listed as compliance; certification not explicit.

c18 drafted · lead FCC Part 15 proposed

Class A limit

review note: support check: partial - FCC Part 15 Class A limit listed as compliance; certification not explicit.

implements

c19 verified · fact Reverse polarity protection

verified by: review-workflowverified on: 2026-10-24

c20 drafted · lead Residual current monitoring

listed as leakage current protection

c21 drafted · lead DC ground-fault protection

listed as ground fault monitoring

c22 drafted · lead String monitoring

c23 drafted · lead Reactive power at night

c24 drafted · lead Surge protection

DC Type II and AC Type II

c25 verified · fact Constant power factor mode

adjustable power factor 0.8 leading to 0.8 lagging

verified by: review-workflowverified on: 2026-10-24

c26 drafted · lead PID recovery

optional feature

c27 drafted · lead DC arc-fault protection

AFCI listed as optional

Referenced by