Solar Lattice

Function

PID recovery

ID
func:pid-recovery
IRI
https://solarlattice.org/kb/func/pid-recovery
Status
active
Also known as
anti-PID, PID protection, PID offset, PID repair, PID night recovery, Integrated PID recovery
Category
Protection
Function kind
protection

PID recovery fixes potential induced degradation in PV modules. At night, when the array is not producing, the inverter applies a compensating voltage between the PV strings and ground. IEA PVPS reports that recovery works if PID is caught early, but it should be confirmed by monitoring. Advanced PID may take months or years to recover, and replacing the modules may be the better fix. Before enabling PID recovery, check the module manufacturer's required polarity to ground. A wrong voltage scheme can stop the function from working or even damage the modules. The Sungrow inverters report a PID abnormity state if the insulation impedance is abnormal or the function cannot run properly after it is enabled.

<!-- review notes

Claims

default_value

c1 drafted · lead nominal 500 V

Scope: products Sungrow SG36/60CX-US

Conditions: PV string-to-ground voltage once PID recovery is enabled; can be changed in the App

c2 drafted · lead nominal 500 V

Scope: products Sungrow SG250HX-US

Conditions: PV string-to-ground voltage once PID recovery is enabled

requires

c3 drafted · lead Sungrow EMU200 proposed

Scope: products Sungrow SG350HX-US

Anti-PID and PID recovery listed as optional via EMU200 on SG350HX-US

review note: support check: partial - Passage shows Anti-PID and PID recovery is optional (EMU200) on SG350HX-US, but 'requires' is stronger than 'optional'.

c4 drafted · lead not Reactive power at night

Scope: products Sungrow SG250HX-US

PID repair cannot run at the same time as night reactive power generation

Referenced by

Data