Product
Solis-3P(125-255)K-EHV-5G-US
- ID
prod:solis-3p-5g-us
- IRI
https://solarlattice.org/kb/prod/solis-3p-5g-us
- Status
- active
- Also known as
- Solis-125K-EHV-5G-US, Solis-185K-EHV-5G-US, Solis-255K-EHV-5G-US
- Category
- Inverters
- Make
- solis
- Product level
- family
Its CSA listing covers wall-mounted, permanently connected installation. The DC input accepts up to 1500 V and uses MC4 connectors. The 255K models connect to an 800 V three-phase grid, and the 185K and 125K-PLUS models connect to 600 V, all at 60 Hz. Maximum efficiency is 98.6 to 99.0 percent depending on the model, and the CEC efficiency is 98.3 percent. Communication is over RS485, with PLC as an option, and the unit has a two-line LCD display. The 185K and 255K models have integrated PID recovery.
<!-- review notes
- sentence 5: support check: partial - RS485/PLC and a 2x20 LCD are supported, but the evidence doesn't say 'two-line' explicitly beyond 2x20 notation; reasonable inference.
-->
Claims
instance_of
c1 drafted · lead
Inverter
Listed as a transformerless grid support utility interactive PV inverter, wall mounted and permanently connected.
compatible_with
c2 verified · fact
Grid-tied PV without storage
Described as a utility interactive PV inverter.
verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Utility interactive PV inverter is stated, but no mention of absence of storage; grid-tied-without-storage is an inference.
uses_protocol
c3 drafted · lead
RS-485
c4 drafted · lead
Power line communication
PLC is listed as an optional communication connection.
implements
c5 drafted · lead
PID recovery
Integrated PID recovery listed for the 185K and 255K models.
max_input_voltage
c6 verified · fact
nominal 1500 V
Conditions: Maximum DC input voltage, Solis-125K-EHV-5G-US-PLUS and Solis-255K-EHV-5G-US
verified by: review-workflowverified on: 2026-10-24
nominal_voltage
c7 drafted · lead
nominal 800 V
Conditions: Rated AC grid voltage (3/PE), Solis-255K-EHV-5G-US and -PLUS
review note: possible conflict with c8 (same source; check the conditions)
c8 drafted · lead
nominal 600 V
Conditions: Rated AC grid voltage (3/PE), Solis-185K-EHV-5G-US and Solis-125K-EHV-5G-US-PLUS
review note: possible conflict with c7 (same source; check the conditions)
rated_output_current
c9 drafted · lead
nominal 184 A
Conditions: Rated output current, Solis-255K-EHV-5G-US
review note: possible conflict with c10 (same source; check the conditions)
c10 drafted · lead
nominal 132.3 A
Conditions: Rated output current, Solis-125K-EHV-5G-US-PLUS
review note: possible conflict with c9 (same source; check the conditions)
frequency
c11 drafted · lead
nominal 60 HZ
Conditions: Rated grid frequency, all listed models
efficiency
c12 verified · fact
nominal 99 PERCENT
Conditions: Maximum efficiency, Solis-255K-EHV-5G-US
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions)
c13 verified · fact
nominal 98.7 PERCENT
Conditions: Maximum efficiency, Solis-185K-EHV-5G-US and -PLUS
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c12 (same source; check the conditions); possible conflict with c14 (same source; check the conditions); possible conflict with c15 (same source; check the conditions)
c14 verified · fact
nominal 98.6 PERCENT
Conditions: Maximum efficiency, Solis-125K-EHV-5G-US-PLUS
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions); possible conflict with c15 (same source; check the conditions)
c15 verified · fact
nominal 98.3 PERCENT
Conditions: CEC efficiency, Solis-125K-EHV-5G-US-PLUS, Solis-185K-EHV-5G-US and Solis-255K-EHV-5G-US
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions)
Referenced by