Product
Solis S6-GU(250-350)K-EHV-US
- ID
prod:solis-s6-gu-ehv-us
- IRI
https://solarlattice.org/kb/prod/solis-s6-gu-ehv-us
- Status
- active
- Also known as
- S6-GU250K-EHV-US, S6-GU300K-EHV-US, S6-GU350K-EHV-US, S6-250K-EHV-US, S6-300K-EHV-US, S6-350K-EHV-US, S6-GU250K-EHV-US-M12, S6-GU300K-EHV-US-M12, S6-GU350K-EHV-US-M12, S6-GU350K-EHV-US-M16, S6-250K-EHV-US-M12, S6-300K-EHV-US-M12, S6-350K-EHV-US-M12, S6-350K-EHV-US-M16
- Category
- Inverters
- Make
- solis
- Product level
- family
The Solis S6-GU(250-350)K-EHV-US is a family of three-phase string inverters made by Solis, with four models: 250K-M12, 300K-M12, 350K-M12 and 350K-M16. The certification listing describes them as transformerless, grid-support, utility-interactive PV inverters that are permanently connected. Every model accepts up to 1500 V DC. The 350K-M12 is rated at 1080 V DC and operates from 480 to 1500 V. Rated output current is 240.6 A on the 250K, 251 A on the 300K and 252.6 A on the 350K-M12. The 300K is rated for a 60 Hz grid. Efficiency is listed as 98.9% maximum and 98.5% CEC. The permitted ambient temperature range is -30 to +60 °C. Integrated AFCI (DC arc-fault protection) and PID recovery are built in. Communication is over RS-485, and PLC is available as an option. A DRM LINK Fail alarm points to a fault on the DRM link. To fix it, restart the inverter, check the DRM cables inside and outside the unit, and confirm the signal is normally closed.
<!-- review notes
- sentence 1: support check: partial - The four models are listed, but 'three-phase string inverters' and Solis as maker are not explicitly stated beyond the name.
- sentence 6: support check: partial - AFCI is YES for all four models, but PID recovery evidence omits the M16 model.
- sentence 1: review: partial - The four model names and the Solis brand are in the passages, but nothing quoted calls them three-phase string inverters.
-->
Claims
manufactured_by
c1 drafted · lead
Solis
review note: support check: partial - Evidence shows a 'solis' label and a certification listing with S6-GU models, but doesn't explicitly state Solis makes them (weakly implied by the name).
implements
c2 drafted · lead
DC arc-fault protection
Integrated AFCI listed as YES for each model in the datasheet tables.
c3 drafted · lead
PID recovery
Integrated PID recovery listed as YES.
review note: support check: partial - PID recovery YES for 250, 300, 350-M12 but the M16 model is not shown.
c6 drafted · lead
Demand response modes (DRM)
The alarm table includes a DRM LINK Fail alarm; the DRM link signal is expected to be normally closed.
review note: support check: partial - The DRM LINK Fail alarm implies DRM support, but no passage explicitly states DRM mode support.
uses_protocol
c4 drafted · lead
RS-485
c5 drafted · lead
Power line communication
PLC is listed as an optional communication connection.
max_input_voltage
c7 drafted · lead
nominal 1500 V
Conditions: Maximum DC input voltage, stated for 250K-M12, 300K-M12, 350K-M12 and 350K-M16 models
rated_output_current
c8 verified · fact
nominal 240.6 A
Conditions: S6-250K-EHV-US-M12 rated output current
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)
c9 drafted · lead
nominal 251 A
Conditions: S6-300K-EHV-US-M12 rated output current
review note: possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)
c10 drafted · lead
nominal 252.6 A
Conditions: S6-350K-EHV-US-M12 rated output current
review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions)
frequency
c11 drafted · lead
nominal 60 HZ
Conditions: Rated grid frequency, S6-300K-EHV-US-M12
efficiency
c12 drafted · lead
nominal 98.5 PERCENT
Conditions: CEC efficiency, stated for 250K-M12, 300K-M12, 350K-M12 and 350K-M16 models
review note: possible conflict with c13 (same source; check the conditions)
c13 drafted · lead
nominal 98.9 PERCENT
Conditions: Maximum efficiency, stated for 250K-M12, 300K-M12, 350K-M12 and 350K-M16 models
review note: possible conflict with c12 (same source; check the conditions)
operating_temperature
c14 verified · fact
-30–60 DEG_C
Conditions: Operating ambient temperature range, stated for 250K-M12, 300K-M12, 350K-M12 and 350K-M16 models
verified by: review-workflowverified on: 2026-10-24