Demand response modes let the utility or grid operator command an inverter remotely through contact signals, as required in Australia by AS/NZS 4777.2. DRM0 disconnects the inverter from the grid, DRM1 brings grid import to zero and DRM5 brings export to zero on utility command. On FIMER UNO-DM PLUS inverters, DRM0 uses the REM terminal block and is enabled with a jumper; if it is enabled without correct wiring, the inverter cannot connect to the grid. Solis inverters have an RJ45 DRM port: pins 5 and 6 switch the inverter on or off, and pins 1 to 4 limit output in stages, for example from a ripple control receiver. DRM is off by default on Solis inverters. If it is turned on while the contact is open or not wired, the display reads Limit by DRM and output is limited to zero. You can enable DRM from the inverter display, over Bluetooth in the SolisCloud app under Grid Code Settings, or in SolisCloud, and it must be set on each inverter separately. KACO blueplanet inverters sold in Australia need a DRM 0 safety label fixed next to the nameplate.
<!-- review notes
setting_rangec1 drafted · lead 0–110 PERCENT
Conditions: Solis DRM port, power level for switch S1
tbl=1.r1 h=2b341e25a908c3 drafted · lead 0–110 PERCENT
Conditions: Solis DRM port, power level for switch S2
tbl=1.r2 h=eccfe9264935c5 drafted · lead 0–110 PERCENT
Conditions: Solis DRM port, power level for switch S3
tbl=1.r3 h=4eb2a83fc75dc7 drafted · lead 0–110 PERCENT
Conditions: Solis DRM port, power level for switch S4
tbl=1.r4 h=67e97f232d9ddefault_valuec2 drafted · lead nominal 30 PERCENT
Conditions: Solis DRM port, power level applied when switch S2 is closed
tbl=1.r2 h=eccfe9264935review note: possible conflict with c4 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
c4 verified · fact nominal 60 PERCENT
Conditions: Solis DRM port, power level applied when switch S3 is closed
tbl=1.r3 h=4eb2a83fc75dverified by: review-workflowverified on: 2026-10-24review note: possible conflict with c2 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
c6 drafted · lead nominal 100 PERCENT
Conditions: Solis DRM port, power level applied when switch S4 is closed
tbl=1.r4 h=67e97f232d9dreview note: possible conflict with c2 (same source; check the conditions); possible conflict with c4 (same source; check the conditions)
response_timeConditions: Solis inverter shutdown and grid disconnection after the S0 contact (pins 5 and 6) is opened
sec=h1 h=6ad7f1571bc0review note: support check: partial - Passage says shutdown within 1 second after S0 opened; 'up to' is implied but fine, though pins 5/6 as S0 is implied by the 0-100% control section; mostly supported.
reconnect_delayConditions: Solis inverter reconnection to grid after the S0 contact is closed again
sec=h1 h=6ad7f1571bc0verified by: review-workflowverified on: 2026-10-24
related_to c4implements c6