Fault codes › Sungrow › Sungrow SG200HX-US
Sungrow SG200HX 514
- Code
514
- Shown as
- Meter Communication Abnormal Alarm
- Page
- 93
- ID
fc:sungrow-sg200hx-514
- IRI
https://solarlattice.org/kb/fc/sungrow-sg200hx-514
- Status
- active
- Also known as
- 514, Sungrow 514, Meter Communication Abnormal Alarm
- Category
- Inverters
Production
not stated
Clears
not stated
Decoded
Reports communication loss; look at energy meter; do: communication cable check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-60-TL W030
- CPS
- CPS SCA36KTL CommErr, CPS SCA50-60KTL CommErr
- Fronius
- Fronius Symo 420
- SMA
- SMA SB-US-40 10252, SMA SB-US-40 10284, SMA SB-US-40 10286, SMA SB-US-40 10341, SMA SB-US-40 10345, SMA SB-US-40 10346, SMA SB-US-40 10347, SMA SB-US-40 10348, SMA SB-US-40 10349, SMA SB-US-40 10350, SMA SB-US-40 10351, SMA SB-US-40 10352, SMA SB-US-40 10353, SMA SB-US-40 7619, SMA SB-US-40 8708, SMA SB-US-41 10249, SMA SB-US-41 10252, SMA SB-US-41 10284, SMA SB-US-41 10286, SMA SB-US-41 10341, SMA SB-US-41 10345, SMA SB-US-41 10346, SMA SB-US-41 10347, SMA SB-US-41 10348, SMA SB-US-41 10349, SMA SB-US-41 10350, SMA SB-US-41 10351, SMA SB-US-41 10352, SMA SB-US-41 10353, SMA SB-US-41 7619, SMA SB-US-41 8708, SMA SBSE-US-50 8104, SMA SBSE-US-50 8708, SMA SBSE-US-50 8709, SMA SBSE-US-50 8710, SMA SBSE-US-50 9308, SMA PEAK3-US 10249, SMA PEAK3-US 10252, SMA PEAK3-US 7619, SMA PEAK3-US 8101, SMA PEAK3-US 8708, SMA PEAK3-US 8709, SMA PEAK3-US 8710, SMA CORE1-US 10249, SMA CORE1-US 10252, SMA CORE1-US 10284, SMA CORE1-US 10286, SMA CORE1-US 7619, SMA CORE1-US 8101, SMA CORE1-US 8102, SMA CORE1-US 8103, SMA CORE1-US 8104, SMA STP-TL-US 8101-8104, SMA STP-TL-US 8708, SMA STP-TL-US 8709, SMA STP-TL-US 8710, SMA STP-X-US 8708, SMA STP-X-US 8709, SMA STP-X-US 8710, SMA SI-US F733, SMA SI-US F754, SMA SI-US W734, SMA SI-US W735, SMA SI-US W736, SMA SI-US W857, SMA SI-US W867, SMA SI-US W877, SMA SI-US W887
- Solis
- Solis S6-EH2P CAN Fail, Solis S6-EH3P30-60K CAN Fail, Solis S6-EH3P75-150K CAN Fail, Solis S6-GC DRM LINK Fail, Solis S6-GU DRM LINK Fail
- Sungrow
- Sungrow SG200HX 75, Sungrow SG250HX 514, Sungrow SG250HX 75, Sungrow SG350HX 514, Sungrow SG350HX 75
- Yaskawa Solectria
- Yaskawa Solectria XGI-1500-1MW WARN-28, Yaskawa Solectria XGI-1500-DCG WARN-28, Yaskawa Solectria XGI-1500 WARN-28
Same code in other families
Claims
defined_in
c1 drafted · lead
Sungrow SG200HX-US User Manual
reports
c2 drafted · lead
Communication loss
affects
c3 drafted · lead
Energy meter
mitigated_by
c4 drafted · lead
Communication cable check
Contact service if the alarm persists.
has_event_class
c5 drafted · lead
Warning (device continues, a condition is flagged)
applies_to
c6 drafted · lead
Sungrow SG200HX-US
Data