Solar Lattice

FailureMode

Duplicate device bus address

ID
fm:duplicate-communication-address
IRI
https://solarlattice.org/kb/fm/duplicate-communication-address
Status
active
Also known as
inverter address conflict, Modbus slave address, set address, default address 1, Duplicate communication address, Physical address conflict, Addr-Conflict

Every inverter, meter or logger on a shared Modbus RS485 bus needs its own slave address, and this failure happens when two devices are given the same one. When addresses clash, neither device communicates properly and the master may lose contact with the whole bus. Some inverters raise a specific alarm, such as Addr-Conflict in Solis parallel systems. Some inverters ship with the same default address, so units on a multi-inverter site must be readdressed during setup. To confirm, read the address setting on each device on the bus and look for duplicates. To fix it, give each device a unique address within its allowed range, following the site design package if there is one. If the alarm stays after readdressing, restart the inverter, and contact the manufacturer if it still persists.

<!-- review notes

Claims

presents_as

c1 drafted · lead Communication loss

When two devices on an RS485 bus share an address, neither one communicates, and the whole serial bus may behave unpredictably.

c2 drafted · lead Address conflict alarm proposed

Solis parallel systems report this as Addr-Conflict (code 1064).

affects

c3 drafted · lead Inverter

c4 drafted · lead Monitoring data logger

The address must not match any other device or the data logger on the bus.

c5 drafted · lead Energy meter

Meters on a Modbus network also need a unique slave ID.

detected_by

c6 drafted · lead Inverter settings review

Check whether two or more units have been given the same address.

review note: support check: partial - u4 says to check whether units share an address, but it doesn't name inverter settings review as a detection method; it is a parallel-system check.

mitigated_by

c7 drafted · lead Inverter restart

Restart only if the fault remains after the addresses have been checked.

c8 drafted · lead Contact manufacturer service

Contact service if the fault persists after a restart.