Solar Lattice

FailureMode

Parallel inverter synchronization fault

ID
fm:parallel-inverter-sync-fault
IRI
https://solarlattice.org/kb/fm/parallel-inverter-sync-fault
Status
active
Also known as
MulMasterErr, Addr-Conflict, HeartbeatLose, MasterLoseErr, SlaveLoseErr, Mode Conflict, SlavePrd-Err, MasterPrd-Err, ModeConflict, MasterSyncLose, SlaveSyncErr, Master/Slave Synchronization Message Failure, Follower Lost Fast Loop synchronization

In a system of inverters running in parallel, the master and slave units lose synchronization or cannot agree on their roles. The inverter shows alarms such as lost master or slave sync signal, an abnormal sync signal period, heartbeat loss, address conflict, multiple masters, or an on-grid/off-grid mode conflict. Common causes are a loose or wrongly connected parallel cable, a cable other than the one supplied, a cable with missing cores out of the 8, or a cable with no shield. Configuration causes include two units with the same address, a host address set to 0 (addresses must start at 1), or more than one unit set as master. Faults with the sync signal period can also come from poor local grid quality, so check the grid as well. Check the DIP switches, address settings, cable shielding and grounding, and firmware compatibility across all units. After you correct the wiring or settings, restart the inverter, and contact customer service if the fault does not clear.

<!-- review notes

Claims

caused_by

c1 drafted · lead Unsuitable communication cable proposed

A parallel cable that is not the one supplied with the product, is missing cores of the 8-core wire, or has no shield can break communication between units.

c2 drafted · lead Installation error

A loose or wrongly connected parallel signal line between inverters.

c3 drafted · lead Duplicate device bus address

Two or more machines in the parallel system set to the same address raise Addr-Conflict.

c4 drafted · lead Inverter parameter settings

Host address set to 0 (addresses must start at 1), or two or more units configured as master.

c5 drafted · lead Poor grid power quality proposed

Poor local grid quality can disturb the master or slave synchronization signal period.

c6 drafted · lead Communication bus wiring or termination fault

Shielding, grounding and DIP switch settings of the parallel communication link are typical checks.

review note: support check: partial - The passage lists DIP switch, shielded cabling and grounding as checks, but does not mention termination or tie them specifically to a bus wiring fault for sync.

affects

c7 drafted · lead Communication cable proposed

c8 drafted · lead Inverter

presents_as

c9 drafted · lead Missing synchronization pulse

c10 drafted · lead Address conflict alarm proposed

c11 drafted · lead Communication loss

Heartbeat packet loss or no communication over the parallel line.

c12 drafted · lead Configuration error

Multiple masters or other parallel configuration conflicts.

mitigated_by

c13 drafted · lead Communication cable check

c14 drafted · lead Inverter settings review

Make sure each unit has a unique address starting from 1 and that only one master exists.

c15 drafted · lead Communication bus termination and cabling practice

Use shielded cabling with proper grounding and check DIP switch settings.

review note: support check: partial - Shielded cabling, grounding and DIP switch checks are stated, but termination is not mentioned.

c16 drafted · lead Inverter restart

c17 drafted · lead Contact manufacturer service