Symptom

Configuration error

ID
symptom:configuration-error
IRI
https://solarlattice.org/kb/symptom/configuration-error
Status
active
Also known as
CONF REV MISMA, Configuration Revision mismatch

A configuration error appears as a status or error message on the device or in the monitoring platform. It is not a physical defect of the PV array. Some meter data includes a counter that starts at zero and goes up each time the configuration changes, so you can use it to check whether the setup was changed. On a SolarEdge commercial inverter, a 'No DHCP' message points to a problem with the IP settings. Check the router and the network configuration, and talk to the site's network IT staff. In the PowerTrack monitoring platform, the Rule Tool has a configuration check. It confirms that the site generates alerts and that at least one person is set up to receive alert notifications. Be careful when editing device driver settings at a live site: changing the data name of a register makes the archived data for that address get lost.