Fault codes › Fronius › Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)

Fronius Symo 483

Code
483
Vendor severity
Class 4
ID
fc:fronius-symo-483
IRI
https://solarlattice.org/kb/fc/fronius-symo-483
Status
active
Also known as
483, Fronius 483
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports configuration error; do: inverter settings review.

What can be behind Configuration error

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E055, ABB / FIMER PVS-166-175-TL E077, ABB / FIMER PVS-60-TL E013, ABB / FIMER PVS-60-TL E055, ABB / FIMER PVS-60-TL E077, ABB / FIMER TRIO-20.0-27.6-TL E013, ABB / FIMER TRIO-20.0-27.6-TL W009, ABB / FIMER UNO-DM-3.3-5.0-PLUS E013, ABB / FIMER UNO-DM-3.3-5.0-PLUS E055, ABB / FIMER UNO-DM-3.3-5.0-PLUS E077, ABB / FIMER UNO-DM-6.0-PLUS E013, ABB / FIMER UNO-DM-6.0-PLUS E055, ABB / FIMER UNO-DM-6.0-PLUS E077
CPS
CPS SCA50-100K-T Protect0720
Fronius
Fronius Galvo 412, Fronius Galvo 445, Fronius Galvo 482, Fronius Galvo 705, Fronius Primo 412, Fronius Primo 445, Fronius Primo 482, Fronius Primo 483, Fronius Primo 705, Fronius Symo 412, Fronius Symo 445, Fronius Symo 482, Fronius Symo 705, Fronius Symo 768, Fronius Symo 773
Generac
Generac PWRcell Inverter 0X7701, Generac PWRcell Inverter 0X7702, Generac PWRcell Inverter 0X7704, Generac PWRcell Inverter 0X7705, Generac PWRcell Inverter 0X7706, Generac PWRcell Inverter 0X7708, Generac PWRcell Inverter 0X7709, Generac PWRcell Inverter 0X770A, Generac PWRcell Inverter 0X770B, Generac PWRcell Inverter 0X770C, Generac PWRcell Inverter 0X7721
KACO new energy
KACO new energy blueplanet TL3 159
SMA
SMA SB-US-40 10343, SMA SB-US-40 10344, SMA SB-US-40 1501, SMA SB-US-40 7347, SMA SB-US-40 7348, SMA SB-US-41 10343, SMA SB-US-41 10344, SMA SB-US-41 1501, SMA SB-US-41 7347, SMA SB-US-41 7348, SMA SBSE-US-50 1501, SMA PEAK3-US 1501, SMA PEAK3-US 7347, SMA PEAK3-US 7348, SMA CORE1-US 7105, SMA CORE1-US 7347, SMA CORE1-US 7348, SMA STP-TL-US 1501, SMA STP-X-US 1501, SMA SI-US F221, SMA SI-US F731, SMA SI-US F732, SMA SI-US F806
Schneider Electric
Schneider Electric CL125 023, Schneider Electric CL125 047
Solis
Solis S6-EH2P BatName-FAIL, Solis S6-EH3P30-60K BatName-FAIL, Solis S6-EH3P75-150K BatName-FAIL
Sungrow
Sungrow SG-CX-US 047
Yaskawa Solectria
Yaskawa Solectria SGI-XTM PAR Backup Err, Yaskawa Solectria SGI-XTM PAR Config Err, Yaskawa Solectria SGI-XTM Pw Brd Mismatch, Yaskawa Solectria XGI-1500 WARN-31

Same code in other families

Claims

defined_in

c1 drafted · lead fronius-symo-ul-emanual-status-codes

reports

c2 drafted · lead Configuration error

Fixed DC voltage setting for MPP2 out of valid range.

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - Not feeding in implies fault, but class 4 link to 483 is not explicit.

has_production_effect

c4 drafted · lead Trip (production stops)

mitigated_by

c5 drafted · lead Inverter settings review

Check MPP settings first; service technician if the code persists.

applies_to

c6 drafted · lead Fronius Symo

Data