| 102 | AC voltage too high |
fault |
stops |
by itself |
Grid overvoltage |
|
| 103 | AC voltage too low |
|
|
by itself |
Grid undervoltage |
|
| 105 | AC frequency too high |
|
stops |
by itself |
Grid overfrequency |
|
| 106 | AC frequency too low |
|
stops |
by itself |
Grid underfrequency |
|
| 107 | No AC grid detected |
|
stops |
by itself |
Grid loss |
|
| 108 | Stand-alone operation detected |
|
stops |
by itself |
Islanding detected |
|
| 112 | RCMU error |
|
|
|
|
|
| 212 | Overvoltage on L1 |
|
stops |
by itself |
Grid overvoltage |
|
| 213 | Undervoltage on L1 |
|
|
|
Grid undervoltage |
|
| 222 | Overvoltage on L2 |
|
|
|
Grid overvoltage |
|
| 223 | Undervoltage on L2 |
|
|
|
Grid undervoltage |
|
| 232 | Overvoltage on L3 |
|
|
|
Grid overvoltage |
|
| 233 | Undervoltage on L3 |
|
|
|
Grid undervoltage |
|
| 240 | Arc detected |
|
|
|
|
|
| 241 | Arc detected |
fault |
stops |
after a manual reset |
|
|
| 242 | Arc detected |
fault |
stops |
after a manual reset |
|
|
| 245 | Arc Detector self-test failed |
fault |
stops |
after a manual reset |
Self-test failure |
|
| 247 | Arc Detector current sensor faulty |
fault |
stops |
|
|
|
| 249 | Arc Detector faulty |
|
|
|
|
|
| 301 | Overcurrent (AC) |
fault |
stops |
by itself |
AC overcurrent |
|
| 302 | Overcurrent (DC) |
|
|
|
DC overcurrent |
|
| 303 | Overtemperature DC module |
fault |
stops |
by itself |
Inverter overtemperature |
|
| 304 | Overtemperature AC module |
|
|
|
Inverter overtemperature |
|
| 305 | No feed-in despite closed relay |
fault |
stops |
by itself |
|
|
| 306 | |
|
stops |
by itself |
Insufficient DC input power |
|
| 307 | |
informational |
|
by itself |
DC undervoltage |
|
| 308 | Intermediate circuit voltage too high |
fault |
stops |
by itself |
DC bus overvoltage |
|
| 309 | DC input voltage MPPT1 too high |
fault |
|
by itself |
DC overvoltage |
|
| 311 | DC strings polarity reversed |
fault |
|
by itself |
Reverse polarity |
|
| 313 | DC input voltage MPPT2 too high |
fault |
|
by itself |
DC overvoltage |
|
| 314 | Timeout current sensor calibration |
fault |
stops |
by itself |
Current sensor calibration timeout |
|
| 315 | AC current sensor fault |
fault |
|
by itself |
|
|
| 316 | InterruptCheck fail |
|
|
|
|
|
| 325 | Overtemperature in connection area |
fault |
|
by itself |
Inverter overtemperature |
|
| 326 | Fan 1 error |
fault |
|
by itself |
Fan fault alarm |
|
| 327 | Fan 2 error |
fault |
|
by itself |
Fan fault alarm |
|
| 401 | Communication with power module is not possible |
fault |
stops |
by itself |
Internal communication failure |
|
| 406 | AC module temperature sensor faulty (L1) |
fault |
|
|
|
|
| 407 | AC module temperature sensor faulty (L2) |
|
|
|
|
|
| 408 | |
|
|
|
High DC injection |
|
| 412 | |
|
|
|
Configuration error |
|
| 415 | Safety cut-out triggered by option card or RECERBO |
fault |
stops |
|
Inverter shutdown |
|
| 416 | No communication between power module and control unit |
fault |
stops |
by itself |
Internal communication failure |
|
| 417 | ID problem with hardware |
fault |
stops |
by itself |
Hardware component incompatibility |
|
| 419 | Unique ID conflict |
|
|
|
|
|
| 420 | Communication with Hybridmanager is not possible |
|
|
|
Communication loss |
|
| 421 | Error HID range |
|
|
|
|
|
| 425 | Communication with the power module is not possible |
|
|
|
Internal communication failure |
|
| 426-428 | Possible hardware defect |
|
|
|
Internal device fault |
|
| 431 | Software problem |
fault |
stops |
after a manual reset |
Internal device fault |
|
| 436 | |
fault |
|
by itself |
Hardware component incompatibility |
|
| 437 | Power module problem |
fault |
|
|
|
|
| 438 | |
fault |
|
by itself |
Hardware component incompatibility |
|
| 443 | Intermediate circuit voltage too low or unsymmetrical |
fault |
stops |
|
DC bus undervoltage |
|
| 445 | |
fault |
stops |
|
Hardware component incompatibility, Configuration error |
|
| 447 | Insulation fault |
fault |
stops |
|
Low insulation resistance |
|
| 448 | Neutral conductor not connected |
fault |
|
|
Abnormal neutral line |
|
| 450 | No guard found |
fault |
|
|
|
|
| 451 | Memory error detected |
fault |
|
by itself |
Data storage failure |
|
| 452 | Communication error between processors |
fault |
|
by itself |
Internal communication failure |
|
| 453 | Grid voltage and power module do not match |
fault |
|
|
Grid voltage out of range |
|
| 454 | Grid frequency and power module do not match |
|
|
|
Grid frequency out of range |
|
| 456 | Anti-islanding function has stopped running properly |
|
|
|
Anti-islanding function malfunction |
|
| 457 | Grid voltage relay error |
fault |
stops |
needs service |
Switching device status fault |
|
| 458 | Error during measuring signal detection |
fault |
stops |
|
Measurement signal error |
|
| 459 | Error during measuring signal detection for insulation test |
|
|
|
Measurement signal error |
|
| 460 | |
|
|
|
Reference voltage out of tolerance |
|
| 461 | Error in DSP data memory |
|
|
|
Internal memory error |
|
| 462 | Error in DC feed-in monitoring routine |
|
|
|
DC injection monitoring error |
|
| 463 | AC polarity reversed, AC connector plugged in incorrectly |
|
|
|
AC polarity reversed |
|
| 474 | RCMU sensor faulty |
fault |
stops |
|
|
|
| 475 | Insulation error (connection between solar module and grounding) |
fault |
stops |
|
Ground fault alarm or trip |
|
| 476 | Supply voltage for driver too low |
fault |
|
|
Driver supply undervoltage |
|
| 479 | Intermediate circuit voltage relay switched off |
fault |
|
by itself |
DC link fault |
|
| 480 | |
fault |
stops |
|
Hardware component incompatibility |
|
| 481 | |
fault |
stops |
|
Hardware component incompatibility |
|
| 482 | Setup interrupted after initial commissioning |
fault |
stops |
after a manual reset |
Configuration error |
|
| 483 | |
fault |
stops |
|
Configuration error |
|
| 485 | CAN transmission buffer is full |
fault |
stops |
after a manual reset |
Internal communication failure |
|
| 489 | |
fault |
stops |
|
DC bus overvoltage |
|
| 502 | Insulation fault on solar modules |
warning |
unaffected |
|
Low insulation resistance |
|
| 509 | No feed-in within the last 24 hours |
warning |
|
after a manual reset |
Extended no feed-in period |
|
| 515 | Communication with filter not possible |
warning |
unaffected |
|
Internal communication failure |
|
| 516 | Communication with memory unit not possible |
warning |
unaffected |
|
Internal communication failure |
|
| 517 | Power derating due to excessive temperature |
warning |
reduced |
by itself |
Inverter overtemperature, Inverter power derating |
|
| 518 | Internal DSP malfunction |
warning |
unaffected |
|
Internal device fault |
|
| 519 | Communication with memory unit not possible |
warning |
unaffected |
after a manual reset |
Internal communication failure |
|
| 520 | |
warning |
|
after a manual reset |
Extended no feed-in period |
|
| 522 | DC low String 1 |
warning |
unaffected |
after a manual reset |
DC undervoltage |
|
| 523 | DC low String 2 |
|
unaffected |
|
DC undervoltage |
|
| 558 | |
|
|
|
Hardware component incompatibility |
|
| 559 | |
warning |
|
|
Hardware component incompatibility |
|
| 560 | Power derating due to over-frequency |
|
reduced |
by itself |
Grid overfrequency |
|
| 564 | |
warning |
|
|
Hardware component incompatibility |
|
| 566 | |
informational |
unaffected |
after a manual reset |
Arc detection disabled |
|
| 568 | Incorrect input signal at the multifunctional power interface |
warning |
|
after a manual reset |
Invalid external input signal |
|
| 572 | Power limitation due to power module |
|
reduced |
|
Inverter power derating |
|
| 573 | Undertemperature warning |
warning |
unaffected |
after a manual reset |
Inverter undertemperature |
|
| 581 | Setup "Special Purpose Utility-Interactive" (SPUI) is activated |
informational |
|
after a manual reset |
Anti-islanding protection disabled |
|
| 601 | CAN bus is full |
fault |
stops |
|
Internal communication failure |
|
| 603 | AC module temperature sensor faulty (L3) |
fault |
stops |
by itself |
|
|
| 604 | DC module temperature sensor faulty |
|
|
|
|
|
| 607 | RCMU fault |
fault |
stops |
after a manual reset |
|
|
| 608 | |
fault |
stops |
|
Hardware component incompatibility |
|
| 701-704 | Provides information about the internal processor status |
warning |
|
|
|
|
| 705 | |
|
|
|
Configuration error |
|
| 706-716 | Provides information about the internal processor status |
warning |
|
|
|
|
| 721 | EEPROM was reinitialized |
warning |
|
after a manual reset |
Internal memory error |
|
| 722-730 | Provides information about the internal processor status |
warning |
|
|
|
|
| 731 | |
warning |
|
|
Unsupported removable storage drive |
|
| 732 | Initialization error – overcurrent at USB flash drive |
|
|
|
USB port overcurrent |
|
| 733 | No USB flash drive inserted |
warning |
|
|
Removable drive not detected |
|
| 734 | |
warning |
|
|
Firmware update failure |
|
| 735 | |
warning |
|
|
Firmware update failure |
|
| 736 | Write or read error occurred |
warning |
|
|
Data storage failure |
|
| 737 | File could not be opened |
warning |
|
|
Data storage failure |
|
| 738 | |
warning |
|
|
Data storage failure |
|
| 740 | |
warning |
|
|
Data storage failure |
|
| 741 | Error when recording logging data |
warning |
|
|
Data storage failure |
|
| 743 | Error occurred during the update |
warning |
|
|
Firmware update failure |
|
| 745 | Update file defective |
warning |
|
|
Firmware update failure |
|
| 746 | Error occurred during the update |
warning |
|
|
Firmware update failure |
|
| 751 | Time lost |
warning |
|
|
System clock time lost |
|
| 752 | Real Time Clock module communication error |
|
|
|
Internal communication failure |
|
| 753 | |
|
unaffected |
|
Inaccurate clock time |
|
| 754-755 | Provides information about the internal processor status |
warning |
|
|
|
|
| 757 | Hardware error in the Real Time Clock module |
fault |
stops |
needs service |
|
|
| 758 | |
|
unaffected |
|
Inaccurate clock time |
|
| 760 | Internal hardware error |
fault |
|
|
Internal device fault |
|
| 761-765 | Provides information about the internal processor status |
warning |
|
|
|
|
| 766 | |
fault |
reduced to 750 W |
|
Inverter power derating |
|
| 767 | Provides information about the internal processor status |
warning |
|
|
|
|
| 768 | Power limit different in the hardware modules |
|
|
|
Configuration error |
|
| 772 | Memory unit unavailable |
|
|
|
Internal memory error |
|
| 773 | Software update group 0 (invalid country setup) |
|
|
|
Configuration error |
|
| 775 | PMC power stage set unavailable |
warning |
|
after a manual reset |
|
|
| 776 | Invalid device type |
|
|
|
|
|
| 781-794 | Provides information about the internal processor status |
warning |
|
|
|
|