Warning (device continues, a condition is flagged)
The device keeps running and flags a condition that deserves attention. Vendor words that read as this class: Chint Warning and Alarm, Yaskawa Solectria Warning, SMA events that say the device continues to feed in.
Reading rule: manuals do not separate alarm from warning consistently (a Chint Alarm continues, a Sungrow alarm may stop), so both read as this class when the device continues; the vendor's word survives in vendor_severity. A message on which the device stops is a fault even when the vendor calls it an alarm.
Referenced by
Every fault code that carries this concept, by make: the cross-vendor answer to which codes trip, derate or clear by themselves.
ABB / FIMER
| Code | Family | Shown as | Claim |
|---|---|---|---|
| ABB / FIMER PVS-166-175-TL W001 | FIMER PVS-166/175-TL-US | Sun Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W011 | FIMER PVS-166/175-TL-US | Bulk UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W012 | FIMER PVS-166/175-TL-US | Batt. Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W013 | FIMER PVS-166/175-TL-US | Clock Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W015 | FIMER PVS-166/175-TL-US | Island Detect. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W018 | FIMER PVS-166/175-TL-US | DC SPD tripped | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W019 | FIMER PVS-166/175-TL-US | AC SPD tripped | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W002 | FIMER PVS-166/175-TL-US | Input UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W021 | FIMER PVS-166/175-TL-US | P-reduction Star t | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W022 | FIMER PVS-166/175-TL-US | Q-mode Change | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W023 | FIMER PVS-166/175-TL-US | Date/time mod. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W024 | FIMER PVS-166/175-TL-US | Energy data rst | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W025 | FIMER PVS-166/175-TL-US | P-reduction End | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W026 | FIMER PVS-166/175-TL-US | AFDD user reset | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W003 | FIMER PVS-166/175-TL-US | Grid Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W004 | FIMER PVS-166/175-TL-US | Grid OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W046 | FIMER PVS-166/175-TL-US | Grid conn. fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W047 | FIMER PVS-166/175-TL-US | Update Incomplete | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W048 | FIMER PVS-166/175-TL-US | Periodic GridOff | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W049 | FIMER PVS-166/175-TL-US | Global-Settings Event | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W005 | FIMER PVS-166/175-TL-US | Grid UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W058 | FIMER PVS-166/175-TL-US | System Frozen | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W006 | FIMER PVS-166/175-TL-US | Grid OF | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-166-175-TL W007 | FIMER PVS-166/175-TL-US | Grid UF | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL CODE:02 | FIMER PVS-60-TL-US | has_event_class c3 verified · fact | |
| ABB / FIMER PVS-60-TL CODE:03 | FIMER PVS-60-TL-US | has_event_class c3 drafted · lead | |
| ABB / FIMER PVS-60-TL CODE:04 | FIMER PVS-60-TL-US | has_event_class c3 drafted · lead | |
| ABB / FIMER PVS-60-TL CODE:05 | FIMER PVS-60-TL-US | has_event_class c3 drafted · lead | |
| ABB / FIMER PVS-60-TL CODE:06 | FIMER PVS-60-TL-US | has_event_class c3 drafted · lead | |
| ABB / FIMER PVS-60-TL W001 | FIMER PVS-60-TL-US | Sun Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W010 | FIMER PVS-60-TL-US | Fan Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W011 | FIMER PVS-60-TL-US | Bulk UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W012 | FIMER PVS-60-TL-US | Batt. Low | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W013 | FIMER PVS-60-TL-US | Clock Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W015 | FIMER PVS-60-TL-US | Island Detect. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W017 | FIMER PVS-60-TL-US | String Err. | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W018 | FIMER PVS-60-TL-US | SPD DC Err | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W019 | FIMER PVS-60-TL-US | SPD AC Err | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W002 | FIMER PVS-60-TL-US | Input UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W021 | FIMER PVS-60-TL-US | P-reductionStart | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W022 | FIMER PVS-60-TL-US | Reactive power mode changed | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W023 | FIMER PVS-60-TL-US | date/time changed | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W024 | FIMER PVS-60-TL-US | Energy data reset | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W025 | FIMER PVS-60-TL-US | P-reductionEnd | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W026 | FIMER PVS-60-TL-US | AFDD user reset | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W027 | FIMER PVS-60-TL-US | Latch-Manual reset | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W003 | FIMER PVS-60-TL-US | Grid Fail | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W030 | FIMER PVS-60-TL-US | Energy Meter ER- ROR | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W004 | FIMER PVS-60-TL-US | Grid OV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W045 | FIMER PVS-60-TL-US | Sys disconnected | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W046 | FIMER PVS-60-TL-US | Grid conn. fault | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W047 | FIMER PVS-60-TL-US | Update Incomplete | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W048 | FIMER PVS-60-TL-US | Periodic GridOff | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W049 | FIMER PVS-60-TL-US | Global-Settings Event | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W005 | FIMER PVS-60-TL-US | Grid UV | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W058 | FIMER PVS-60-TL-US | System Frozen | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W006 | FIMER PVS-60-TL-US | Grid OF | has_event_class c2 drafted · lead |
| ABB / FIMER PVS-60-TL W007 | FIMER PVS-60-TL-US | Grid UF | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL CODE:02 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c3 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL CODE:03 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c3 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL CODE:04 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c3 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL CODE:05 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c3 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL CODE:06 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c3 verified · fact | |
| ABB / FIMER TRIO-20.0-27.6-TL W001 | TRIO-20.0/27.6-TL-OUTD(-US) | Sun Low | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W010 | TRIO-20.0/27.6-TL-OUTD(-US) | Fan broken! | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W011 | TRIO-20.0/27.6-TL-OUTD(-US) | Bulk UV | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W012 | TRIO-20.0/27.6-TL-OUTD(-US) | Batt. Flat | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W013 | TRIO-20.0/27.6-TL-OUTD(-US) | Clock broken | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W017 | TRIO-20.0/27.6-TL-OUTD(-US) | String Err. | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W018 | TRIO-20.0/27.6-TL-OUTD(-US) | SPD DC Err | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W019 | TRIO-20.0/27.6-TL-OUTD(-US) | SPD AC Err | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W002 | TRIO-20.0/27.6-TL-OUTD(-US) | Input UV | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W022 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c2 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL W023 | TRIO-20.0/27.6-TL-OUTD(-US) | date/time changed | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W024 | TRIO-20.0/27.6-TL-OUTD(-US) | has_event_class c2 drafted · lead | |
| ABB / FIMER TRIO-20.0-27.6-TL W003 | TRIO-20.0/27.6-TL-OUTD(-US) | Grid Fail | has_event_class c2 drafted · lead |
| ABB / FIMER TRIO-20.0-27.6-TL W009 | TRIO-20.0/27.6-TL-OUTD(-US) | Empty Table | has_event_class c2 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:02 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | has_event_class c3 drafted · lead | |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:03 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:04 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | has_event_class c3 drafted · lead | |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:05 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:06 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W001 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Sun Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W010 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Fan Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W011 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Bulk UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W012 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Batt. Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W013 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Clock Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W015 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Island Detect. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W017 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | String Err. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W018 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | SPD DC Err | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W019 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | SPD AC Err | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W002 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Input UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W022 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Reactive power mode changed | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W023 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | date/time changed | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W024 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Energy data reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W026 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | AFDD user reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W027 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Latch-Manual reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W003 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W004 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W046 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid conn. fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W047 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Update Incomplete | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W048 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Periodic GridOff | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W049 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Global-Settings Event | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W005 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W058 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | System Frozen | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W006 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid OF | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-3.3-5.0-PLUS W007 | UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-US | Grid UF | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS CODE:02 | UNO-DM-6.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-6.0-PLUS CODE:03 | UNO-DM-6.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-6.0-PLUS CODE:04 | UNO-DM-6.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-6.0-PLUS CODE:05 | UNO-DM-6.0-TL-PLUS-US | has_event_class c3 verified · fact | |
| ABB / FIMER UNO-DM-6.0-PLUS CODE:06 | UNO-DM-6.0-TL-PLUS-US | has_event_class c3 drafted · lead | |
| ABB / FIMER UNO-DM-6.0-PLUS W001 | UNO-DM-6.0-TL-PLUS-US | Sun Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W010 | UNO-DM-6.0-TL-PLUS-US | Fan Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W011 | UNO-DM-6.0-TL-PLUS-US | Bulk UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W012 | UNO-DM-6.0-TL-PLUS-US | Batt. Low | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W013 | UNO-DM-6.0-TL-PLUS-US | Clock Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W015 | UNO-DM-6.0-TL-PLUS-US | Island Detect. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W017 | UNO-DM-6.0-TL-PLUS-US | String Err. | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W018 | UNO-DM-6.0-TL-PLUS-US | SPD DC Err | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W019 | UNO-DM-6.0-TL-PLUS-US | SPD AC Err | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W002 | UNO-DM-6.0-TL-PLUS-US | Input UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W022 | UNO-DM-6.0-TL-PLUS-US | Reactive power mode changed | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W023 | UNO-DM-6.0-TL-PLUS-US | date/time changed | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W024 | UNO-DM-6.0-TL-PLUS-US | Energy data reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W026 | UNO-DM-6.0-TL-PLUS-US | AFDD user reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W027 | UNO-DM-6.0-TL-PLUS-US | Latch-Manual reset | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W003 | UNO-DM-6.0-TL-PLUS-US | Grid Fail | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W004 | UNO-DM-6.0-TL-PLUS-US | Grid OV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W046 | UNO-DM-6.0-TL-PLUS-US | Grid conn. fault | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W047 | UNO-DM-6.0-TL-PLUS-US | Update Incomplete | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W048 | UNO-DM-6.0-TL-PLUS-US | Periodic GridOff | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W049 | UNO-DM-6.0-TL-PLUS-US | Global-Settings Event | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W005 | UNO-DM-6.0-TL-PLUS-US | Grid UV | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W058 | UNO-DM-6.0-TL-PLUS-US | System Frozen | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W006 | UNO-DM-6.0-TL-PLUS-US | Grid OF | has_event_class c3 drafted · lead |
| ABB / FIMER UNO-DM-6.0-PLUS W007 | UNO-DM-6.0-TL-PLUS-US | Grid UF | has_event_class c3 drafted · lead |
CPS
| Code | Family | Shown as | Claim |
|---|---|---|---|
| CPS SCA25KTL-208 CommErr | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 EepromErr | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 ExtFanErr | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 TempSensorErr | CPS SCA25KTL-DO/US-208 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-208 Warn0030 | CPS SCA25KTL-DO/US-208 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCA25KTL-208 Warn0050 | CPS SCA25KTL-DO/US-208 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 CommErr | CPS SCA25KTL-DO-R/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA25KTL-480 Warn0100 | CPS SCA25KTL-DO-R/US-480 | AC SPD fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Warn0030 | CPS SCA25KTL-DO-R/US-480 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Warn0040 | CPS SCA25KTL-DO-R/US-480 | DC SPD fault | has_event_class c2 drafted · lead |
| CPS SCA25KTL-480 Warn0050 | CPS SCA25KTL-DO-R/US-480 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCA36KTL CommErr | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL EepromErr | CPS SCA36KTL-DO/US-480 | has_event_class c3 verified · fact | |
| CPS SCA36KTL ExtFanErr | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL IntFanErr | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL TempSensorErr | CPS SCA36KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA36KTL Warn0100 | CPS SCA36KTL-DO/US-480 | AC SPD | has_event_class c2 drafted · lead |
| CPS SCA36KTL Warn0030 | CPS SCA36KTL-DO/US-480 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCA36KTL Warn0040 | CPS SCA36KTL-DO/US-480 | DC SPD | has_event_class c2 drafted · lead |
| CPS SCA36KTL Warn0050 | CPS SCA36KTL-DO/US-480 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0000 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Ex Fan Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0010 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | In Fan Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0100 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | AC lightning protector Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0020 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | CAN Comm Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0030 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Eeprom Fault | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0040 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | DC lightning protector Abn | has_event_class c2 drafted · lead |
| CPS SCA50-100K-T Warn0050 | CPS SCA100K-T-US-480 / SCA50K-T-US-208 | Temp Sensor Abn | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL CommErr | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL EepromErr | CPS SCA50/60KTL-DO/US-480 | has_event_class c3 drafted · lead | |
| CPS SCA50-60KTL ExtFanErr | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL IntFanErr | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL TempSensorErr | CPS SCA50/60KTL-DO/US-480 | has_event_class c2 drafted · lead | |
| CPS SCA50-60KTL Warn0100 | CPS SCA50/60KTL-DO/US-480 | AC SPD | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Warn0030 | CPS SCA50/60KTL-DO/US-480 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Warn0040 | CPS SCA50/60KTL-DO/US-480 | DC SPD | has_event_class c2 drafted · lead |
| CPS SCA50-60KTL Warn0050 | CPS SCA50/60KTL-DO/US-480 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL CommErr | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL ExtFanErr | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL IntFanErr | CPS SCH100/125KTL-DO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH100-125KTL Warn0100 | CPS SCH100/125KTL-DO/US-600 | AC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Warn0030 | CPS SCH100/125KTL-DO/US-600 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Warn0040 | CPS SCH100/125KTL-DO/US-600 | DC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH100-125KTL Warn0050 | CPS SCH100/125KTL-DO/US-600 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO CommErr | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO ExtFanErr | CPS SCH125KTL-AIO/US-600 | has_event_class c2 drafted · lead | |
| CPS SCH125KTL-AIO Warn0100 | CPS SCH125KTL-AIO/US-600 | AC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Warn0030 | CPS SCH125KTL-AIO/US-600 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Warn0040 | CPS SCH125KTL-AIO/US-600 | DC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH125KTL-AIO Warn0050 | CPS SCH125KTL-AIO/US-600 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Warn0030 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCH200-250K-T Warn0050 | CPS SCH200K-T-US-480 / SCH250K-T-US-600 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH275KTL CommErr | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL ExtFanErr | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL IntFanErr | CPS SCH275KTL-DO/US-800 | has_event_class c2 drafted · lead | |
| CPS SCH275KTL Warn0100 | CPS SCH275KTL-DO/US-800 | AC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Warn0030 | CPS SCH275KTL-DO/US-800 | EepromErr | has_event_class c2 drafted · lead |
| CPS SCH275KTL Warn0040 | CPS SCH275KTL-DO/US-800 | DC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH275KTL Warn0050 | CPS SCH275KTL-DO/US-800 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH350KTL CfLowErr | CPS SCH350KTL-DO/US-800 | voltage across flying capacitor too low | has_event_class c3 verified · fact |
| CPS SCH350KTL Warn0100 | CPS SCH350KTL-DO/US-800 | AC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Warn0030 | CPS SCH350KTL-DO/US-800 | Eeprom error | has_event_class c2 drafted · lead |
| CPS SCH350KTL Warn0040 | CPS SCH350KTL-DO/US-800 | DC SPD fault | has_event_class c2 drafted · lead |
| CPS SCH350KTL Warn0050 | CPS SCH350KTL-DO/US-800 | TempSensorErr | has_event_class c2 drafted · lead |
| CPS SCH350KTL Warn0080 | CPS SCH350KTL-DO/US-800 | external heat exchanger fan error | has_event_class c2 drafted · lead |
Canadian Solar
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Canadian Solar 23-28KTL-CT CommErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT EepromErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT ExtFanErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead | |
| Canadian Solar 23-28KTL-CT TempSensorErr | CSI 23/28KTL-CT/US-480 | has_event_class c2 drafted · lead |
Fronius
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Fronius Galvo 502 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Insulation error on the solar modules | has_event_class c5 drafted · lead |
| Fronius Galvo 509 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | No feed-in within the last 24 hours | has_event_class c3 drafted · lead |
| Fronius Galvo 517 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Power derating due to excessive temperature | has_event_class c4 drafted · lead |
| Fronius Galvo 551 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Fuse for solar module ground is defective | has_event_class c5 drafted · lead |
| Fronius Galvo 721 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | EEPROM was reinitialized or EEPROM defective | has_event_class c3 drafted · lead |
| Fronius Galvo 731 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c4 drafted · lead | |
| Fronius Galvo 733 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | No USB thumb drive inserted | has_event_class c5 drafted · lead |
| Fronius Galvo 734 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c4 drafted · lead | |
| Fronius Galvo 735 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c5 drafted · lead | |
| Fronius Galvo 736 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Write or read error occurred | has_event_class c6 drafted · lead |
| Fronius Galvo 738 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | has_event_class c6 drafted · lead | |
| Fronius Galvo 743 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Error occurred during the update | has_event_class c5 drafted · lead |
| Fronius Galvo 745 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Update file defective | has_event_class c5 drafted · lead |
| Fronius Galvo 751 | Fronius Galvo 208-240 (1.5-1 to 3.1-1) | Time lost | has_event_class c4 drafted · lead |
| Fronius Primo 502 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Insulation fault on solar modules | has_event_class c5 drafted · lead |
| Fronius Primo 509 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | No feed-in within the last 24 hours | has_event_class c3 verified · fact |
| Fronius Primo 515 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Communication with filter not possible | has_event_class c4 drafted · lead |
| Fronius Primo 516 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Communication with memory unit not possible | has_event_class c4 drafted · lead |
| Fronius Primo 517 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Power derating due to excessive temperature | has_event_class c4 drafted · lead |
| Fronius Primo 522 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | DC low String 1 | has_event_class c3 drafted · lead |
| Fronius Primo 721 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | EEPROM was reinitialized or EEPROM defective | has_event_class c3 drafted · lead |
| Fronius Primo 731 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c4 drafted · lead | |
| Fronius Primo 733 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | No USB thumb drive inserted | has_event_class c5 drafted · lead |
| Fronius Primo 734 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c4 drafted · lead | |
| Fronius Primo 735 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c5 drafted · lead | |
| Fronius Primo 736 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Write or read error occurred | has_event_class c6 drafted · lead |
| Fronius Primo 738 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | has_event_class c6 drafted · lead | |
| Fronius Primo 743 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Error occurred during the update | has_event_class c5 drafted · lead |
| Fronius Primo 745 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Update file defective | has_event_class c5 drafted · lead |
| Fronius Primo 751 | Fronius Primo 208-240 (3.8-1 to 15.0-1) | Time lost | has_event_class c4 drafted · lead |
| Fronius Symo 502 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Insulation fault on solar modules | has_event_class c5 drafted · lead |
| Fronius Symo 509 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | No feed-in within the last 24 hours | has_event_class c3 drafted · lead |
| Fronius Symo 515 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Communication with filter not possible | has_event_class c4 drafted · lead |
| Fronius Symo 516 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Communication with memory unit not possible | has_event_class c4 drafted · lead |
| Fronius Symo 517 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Power derating due to excessive temperature | has_event_class c4 drafted · lead |
| Fronius Symo 518 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Internal DSP malfunction | has_event_class c4 drafted · lead |
| Fronius Symo 519 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Communication with memory unit not possible | has_event_class c4 drafted · lead |
| Fronius Symo 520 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c4 drafted · lead | |
| Fronius Symo 522 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | DC low String 1 | has_event_class c3 drafted · lead |
| Fronius Symo 559 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c5 drafted · lead | |
| Fronius Symo 564 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c5 drafted · lead | |
| Fronius Symo 568 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Incorrect input signal at the multifunctional power interface | has_event_class c4 drafted · lead |
| Fronius Symo 573 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Undertemperature warning | has_event_class c3 drafted · lead |
| Fronius Symo 701-704 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 706-716 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 721 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | EEPROM was reinitialized | has_event_class c3 drafted · lead |
| Fronius Symo 722-730 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 731 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c4 drafted · lead | |
| Fronius Symo 733 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | No USB flash drive inserted | has_event_class c5 drafted · lead |
| Fronius Symo 734 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c4 drafted · lead | |
| Fronius Symo 735 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c5 drafted · lead | |
| Fronius Symo 736 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Write or read error occurred | has_event_class c6 drafted · lead |
| Fronius Symo 737 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | File could not be opened | has_event_class c6 drafted · lead |
| Fronius Symo 738 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c6 drafted · lead | |
| Fronius Symo 740 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | has_event_class c5 drafted · lead | |
| Fronius Symo 741 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Error when recording logging data | has_event_class c6 drafted · lead |
| Fronius Symo 743 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Error occurred during the update | has_event_class c5 drafted · lead |
| Fronius Symo 745 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Update file defective | has_event_class c5 drafted · lead |
| Fronius Symo 746 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Error occurred during the update | has_event_class c4 drafted · lead |
| Fronius Symo 751 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Time lost | has_event_class c4 drafted · lead |
| Fronius Symo 754-755 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 761-765 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 767 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
| Fronius Symo 775 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | PMC power stage set unavailable | has_event_class c2 drafted · lead |
| Fronius Symo 781-794 | Fronius Symo UL (10.0-3 to 24.0-3 208-240/480) | Provides information about the internal processor status | has_event_class c2 drafted · lead |
Huawei
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Huawei SUN2000-100KTL-USH0 2012 | Huawei SUN2000-100KTL-USH0 | String current backfeed | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2013 | Huawei SUN2000-100KTL-USH0 | Abnormal String Power | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2065 | Huawei SUN2000-100KTL-USH0 | Upgrade Failed | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 2066 | Huawei SUN2000-100KTL-USH0 | License Expired | has_event_class c2 drafted · lead |
| Huawei SUN2000-100KTL-USH0 61440 | Huawei SUN2000-100KTL-USH0 | Faulty Monitoring Unit | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 106-111 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | String 1-6 Abnormal | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 504 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Version Mismatch | has_event_class c2 drafted · lead |
| Huawei SUN2000-25-30KTL-US 61440 | Huawei SUN2000-25KTL-US / SUN2000-30KTL-US | Flash Fault | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 106-113 | Huawei SUN2000-45KTL-US-HV-D0 | Abnormal String 1-8 | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 504 | Huawei SUN2000-45KTL-US-HV-D0 | Software Version Unmatch | has_event_class c2 drafted · lead |
| Huawei SUN2000-45KTL-US-HV-D0 61440 | Huawei SUN2000-45KTL-US-HV-D0 | Flash Fault | has_event_class c2 drafted · lead |
KACO new energy
| Code | Family | Shown as | Claim |
|---|---|---|---|
| KACO new energy blueplanet TL3 107 | KACO blueplanet 87.0-165 TL3 | Check surge protection device | has_event_class c7 drafted · lead |
| KACO new energy blueplanet TL3 158 | KACO blueplanet 87.0-165 TL3 | Power limitation | has_event_class c4 drafted · lead |
| KACO new energy blueplanet TL3 187 | KACO blueplanet 87.0-165 TL3 | Fault in fan 4 | has_event_class c8 drafted · lead |
SMA
| Code | Family | Shown as | Claim |
|---|---|---|---|
| SMA SB-US-40 10284 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | No WLAN connection possible | has_event_class c4 drafted · lead |
| SMA SB-US-40 10286 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | WLAN connection lost | has_event_class c4 drafted · lead |
| SMA SB-US-40 6701-6702 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | has_event_class c5 drafted · lead | |
| SMA SB-US-40 7106 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | has_event_class c6 drafted · lead | |
| SMA SB-US-40 7110 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | has_event_class c4 drafted · lead | |
| SMA SB-US-40 8003 | Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40) | Active power limited derating | has_event_class c10 drafted · lead |
| SMA SB-US-41 10248 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | |tn4|: network busy | has_event_class c4 drafted · lead |
| SMA SB-US-41 10284 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | No WiFi connection possible | has_event_class c4 drafted · lead |
| SMA SB-US-41 10286 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Wi-Fi connection lost | has_event_class c4 drafted · lead |
| SMA SB-US-41 6701 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Communication impaired | has_event_class c5 drafted · lead |
| SMA SB-US-41 6702 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Communication impaired | has_event_class c5 drafted · lead |
| SMA SB-US-41 7106 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | has_event_class c6 drafted · lead | |
| SMA SB-US-41 7110 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | No update file found | has_event_class c4 drafted · lead |
| SMA SB-US-41 8003 | Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41) | Temperature derating | has_event_class c10 drafted · lead |
| SMA SBSE-US-50 8003 | Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50) | Temperature derating | has_event_class c10 drafted · lead |
| SMA PEAK3-US 10248 | Sunny Highpower PEAK3 (SHP 125-172-US) | |tn4|: network busy | has_event_class c4 drafted · lead |
| SMA PEAK3-US 6701 | Sunny Highpower PEAK3 (SHP 125-172-US) | Communication impaired | has_event_class c5 drafted · lead |
| SMA PEAK3-US 7102 | Sunny Highpower PEAK3 (SHP 125-172-US) | Parameter file not found or defective | has_event_class c4 drafted · lead |
| SMA PEAK3-US 7801 | Sunny Highpower PEAK3 (SHP 125-172-US) | Fault overvoltage protector | has_event_class c7 drafted · lead |
| SMA PEAK3-US 8003 | Sunny Highpower PEAK3 (SHP 125-172-US) | Temperature derating | has_event_class c10 drafted · lead |
| SMA CORE1-US 10248 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | [Interface]: network busy | has_event_class c4 drafted · lead |
| SMA CORE1-US 10284 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | No Wi-Fi connection possible | has_event_class c4 drafted · lead |
| SMA CORE1-US 10286 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Wi-Fi connection lost | has_event_class c6 drafted · lead |
| SMA CORE1-US 6701 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c7 drafted · lead | |
| SMA CORE1-US 6702 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c7 drafted · lead | |
| SMA CORE1-US 7102 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c6 verified · fact | |
| SMA CORE1-US 7105 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c7 drafted · lead | |
| SMA CORE1-US 7106 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c8 verified · fact | |
| SMA CORE1-US 7110 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | has_event_class c6 drafted · lead | |
| SMA CORE1-US 7801 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Fault overvoltage protector | has_event_class c7 drafted · lead |
| SMA CORE1-US 8003 | Sunny Tripower CORE1-US (STP 33/50/62-US-41) | Active power limit Temperature | has_event_class c11 drafted · lead |
| SMA STP-TL-US 6701-6702 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c5 drafted · lead | |
| SMA STP-TL-US 7102 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c4 drafted · lead | |
| SMA STP-TL-US 7105 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c5 drafted · lead | |
| SMA STP-TL-US 7106 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c6 drafted · lead | |
| SMA STP-TL-US 7110 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c4 drafted · lead | |
| SMA STP-TL-US 7201-7202 | Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10) | has_event_class c3 drafted · lead | |
| SMA STP-X-US 7801 | Sunny Tripower X 13-30-US (STP xx-US-50) | Fault overvoltage protector | has_event_class c7 drafted · lead |
| SMA SC-CP-XT 3515 | Sunny Central 500CP XT-1000CP XT | has_event_class c5 drafted · lead | |
| SMA SC-CP-XT 7801 | Sunny Central 500CP XT-1000CP XT | has_event_class c7 drafted · lead | |
| SMA SC-CP-XT 8701 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 8702 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 8703 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SC-CP-XT 8704 | Sunny Central 500CP XT-1000CP XT | has_event_class c3 drafted · lead | |
| SMA SI-US W110 | Sunny Island 4548-US / 6048-US | Overtemperature transformer slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W111 | Sunny Island 4548-US / 6048-US | Overtemperature transformer slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W112 | Sunny Island 4548-US / 6048-US | Overtemperature transformer slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W114 | Sunny Island 4548-US / 6048-US | Overtemperature heat sink slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W115 | Sunny Island 4548-US / 6048-US | Overtemperature heat sink slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W116 | Sunny Island 4548-US / 6048-US | Overtemperature heat sink slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W118 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W119 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W120 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W122 | Sunny Island 4548-US / 6048-US | Inverter overvoltage slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W123 | Sunny Island 4548-US / 6048-US | Inverter overvoltage slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W124 | Sunny Island 4548-US / 6048-US | Inverter overvoltage slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W137 | Sunny Island 4548-US / 6048-US | Derating due to temperature (heat sink or transformer) | has_event_class c2 drafted · lead |
| SMA SI-US W138 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W139 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W140 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W142 | Sunny Island 4548-US / 6048-US | Inverter undervoltage slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W143 | Sunny Island 4548-US / 6048-US | Inverter undervoltage slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W144 | Sunny Island 4548-US / 6048-US | Inverter undervoltage slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W159 | Sunny Island 4548-US / 6048-US | Voltage on output AC1 slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W160 | Sunny Island 4548-US / 6048-US | Voltage on output AC1 slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W161 | Sunny Island 4548-US / 6048-US | Voltage on output AC1 slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W202 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W203 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W204 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W209 | Sunny Island 4548-US / 6048-US | Battery overvoltage error | has_event_class c2 drafted · lead |
| SMA SI-US W210 | Sunny Island 4548-US / 6048-US | Battery overvoltage warning | has_event_class c2 drafted · lead |
| SMA SI-US W211 | Sunny Island 4548-US / 6048-US | Low battery temperature warning | has_event_class c2 drafted · lead |
| SMA SI-US W212 | Sunny Island 4548-US / 6048-US | High battery temperature warning | has_event_class c2 drafted · lead |
| SMA SI-US W220 | Sunny Island 4548-US / 6048-US | Warning SOH < 70% | has_event_class c2 drafted · lead |
| SMA SI-US W309 | Sunny Island 4548-US / 6048-US | Relay protection | has_event_class c2 drafted · lead |
| SMA SI-US W310 | Sunny Island 4548-US / 6048-US | Relay protection slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W311 | Sunny Island 4548-US / 6048-US | Relay protection slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W312 | Sunny Island 4548-US / 6048-US | Relay protection slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W315 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W316 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W317 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W318 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W319 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W320 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W321 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W322 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W323 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W324 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W325 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W326 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W327 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W328 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W329 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W330 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W331 | Sunny Island 4548-US / 6048-US | Disconnection from utility grid/generator due to islanding | has_event_class c2 drafted · lead |
| SMA SI-US W332 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W333 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W334 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W335 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W336 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W337 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W338 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W339 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W340 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W341 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W342 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W343 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W344 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W345 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W346 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W347 | Sunny Island 4548-US / 6048-US | Disconnection from external source due to excessive load | has_event_class c2 drafted · lead |
| SMA SI-US W348 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W349 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W350 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W351 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W352 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W353 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W354 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W377 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W378 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W379 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W380 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W401 | Sunny Island 4548-US / 6048-US | Reverse power protection (generator) | has_event_class c2 drafted · lead |
| SMA SI-US W402 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W501 | Sunny Island 4548-US / 6048-US | Grid reverse current prevented (quick grid disconnection) | has_event_class c2 drafted · lead |
| SMA SI-US W502 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W503 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W504 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W505 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W506 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W507 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W508 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W606 | Sunny Island 4548-US / 6048-US | Transfer relay does not open slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W607 | Sunny Island 4548-US / 6048-US | Transfer relay does not open slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W608 | Sunny Island 4548-US / 6048-US | Transfer relay does not open slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W705 | Sunny Island 4548-US / 6048-US | Watchdog DSP has been tripped | has_event_class c2 drafted · lead |
| SMA SI-US W707 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W708 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W709 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W713 | Sunny Island 4548-US / 6048-US | Watchdog has been tripped | has_event_class c2 drafted · lead |
| SMA SI-US W717 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W718 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W719 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W722 | Sunny Island 4548-US / 6048-US | Short circuit on battery temperature sensor | has_event_class c2 drafted · lead |
| SMA SI-US W723 | Sunny Island 4548-US / 6048-US | Cable break on battery temperature sensor | has_event_class c2 drafted · lead |
| SMA SI-US W724 | Sunny Island 4548-US / 6048-US | Autostart meter slave 1 elapsed | has_event_class c2 drafted · lead |
| SMA SI-US W725 | Sunny Island 4548-US / 6048-US | Autostart meter slave 2 elapsed | has_event_class c2 drafted · lead |
| SMA SI-US W726 | Sunny Island 4548-US / 6048-US | Autostart meter slave 3 elapsed | has_event_class c2 drafted · lead |
| SMA SI-US W734 | Sunny Island 4548-US / 6048-US | No message from cluster slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W735 | Sunny Island 4548-US / 6048-US | No message from cluster slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W736 | Sunny Island 4548-US / 6048-US | No message from cluster slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W738 | Sunny Island 4548-US / 6048-US | Synchronization not successful | has_event_class c2 drafted · lead |
| SMA SI-US W740 | Sunny Island 4548-US / 6048-US | Internal device communication of slave 1 interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W741 | Sunny Island 4548-US / 6048-US | Internal device communication of slave 2 interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W742 | Sunny Island 4548-US / 6048-US | Internal device communication of slave 3 interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W744 | Sunny Island 4548-US / 6048-US | Internal CAN communication of slave 1 is interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W745 | Sunny Island 4548-US / 6048-US | Internal CAN communication of slave 2 is interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W746 | Sunny Island 4548-US / 6048-US | Internal CAN communication of slave 3 is interrupted | has_event_class c2 drafted · lead |
| SMA SI-US W747 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W748 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W749 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W750 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W751 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W752 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W753 | Sunny Island 4548-US / 6048-US | Invalid system time | has_event_class c2 drafted · lead |
| SMA SI-US W755 | Sunny Island 4548-US / 6048-US | Battery-preservation mode 1 (LBM) | has_event_class c2 drafted · lead |
| SMA SI-US W756 | Sunny Island 4548-US / 6048-US | Battery-preservation mode 2 (LBM) | has_event_class c2 drafted · lead |
| SMA SI-US W757 | Sunny Island 4548-US / 6048-US | Battery-preservation mode 3 (LBM) | has_event_class c2 drafted · lead |
| SMA SI-US W759 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W760 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W761 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W784 | Sunny Island 4548-US / 6048-US | Slave does not receive a Syncpuls Slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W785 | Sunny Island 4548-US / 6048-US | Slave does not receive a Syncpuls Slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W786 | Sunny Island 4548-US / 6048-US | Slave does not receive a Syncpuls Slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W791 | Sunny Island 4548-US / 6048-US | DSP reset detected on slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W792 | Sunny Island 4548-US / 6048-US | DSP reset detected on slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W793 | Sunny Island 4548-US / 6048-US | DSP reset detected on slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W797 | Sunny Island 4548-US / 6048-US | Failure of the grid monitoring slave 1 | has_event_class c2 drafted · lead |
| SMA SI-US W798 | Sunny Island 4548-US / 6048-US | Failure of the grid monitoring slave 2 | has_event_class c2 drafted · lead |
| SMA SI-US W799 | Sunny Island 4548-US / 6048-US | Failure of the grid monitoring slave 3 | has_event_class c2 drafted · lead |
| SMA SI-US W804 | Sunny Island 4548-US / 6048-US | Grid operation not possible | has_event_class c2 drafted · lead |
| SMA SI-US W805 | Sunny Island 4548-US / 6048-US | Generator operation not possible | has_event_class c2 drafted · lead |
| SMA SI-US W807 | Sunny Island 4548-US / 6048-US | No valid line voltage for requested grid operation | has_event_class c2 drafted · lead |
| SMA SI-US W808 | Sunny Island 4548-US / 6048-US | Error Q4 contactor | has_event_class c2 drafted · lead |
| SMA SI-US W815 | Sunny Island 4548-US / 6048-US | Error Q5 contactor | has_event_class c2 drafted · lead |
| SMA SI-US W824 | Sunny Island 4548-US / 6048-US | Error Q4 contactor | has_event_class c2 drafted · lead |
| SMA SI-US W851 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W852 | Sunny Island 4548-US / 6048-US | Battery overvoltage Sunny Island Charger 1 | has_event_class c2 drafted · lead |
| SMA SI-US W853 | Sunny Island 4548-US / 6048-US | Overvoltage PV array Sunny Island Charger 1 | has_event_class c2 drafted · lead |
| SMA SI-US W854 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W855 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W856 | Sunny Island 4548-US / 6048-US | Overtemperature Sunny Island Charger 1 | has_event_class c2 drafted · lead |
| SMA SI-US W857 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W861 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W862 | Sunny Island 4548-US / 6048-US | Battery overvoltage Sunny Island Charger 2 | has_event_class c2 drafted · lead |
| SMA SI-US W863 | Sunny Island 4548-US / 6048-US | Overvoltage PV array Sunny Island Charger 2 | has_event_class c2 drafted · lead |
| SMA SI-US W864 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W865 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W866 | Sunny Island 4548-US / 6048-US | Overtemperature Sunny Island Charger 2 | has_event_class c2 drafted · lead |
| SMA SI-US W867 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W871 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W872 | Sunny Island 4548-US / 6048-US | Battery overvoltage Sunny Island Charger 3 | has_event_class c2 drafted · lead |
| SMA SI-US W873 | Sunny Island 4548-US / 6048-US | Overvoltage PV array Sunny Island Charger 3 | has_event_class c2 drafted · lead |
| SMA SI-US W874 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W875 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W876 | Sunny Island 4548-US / 6048-US | Overtemperature Sunny Island Charger 3 | has_event_class c2 drafted · lead |
| SMA SI-US W877 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W881 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W882 | Sunny Island 4548-US / 6048-US | Battery overvoltage Sunny Island Charger 4 | has_event_class c2 drafted · lead |
| SMA SI-US W883 | Sunny Island 4548-US / 6048-US | Overvoltage PV array Sunny Island Charger 4 | has_event_class c2 drafted · lead |
| SMA SI-US W884 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W885 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W886 | Sunny Island 4548-US / 6048-US | Overtemperature Sunny Island Charger 4 | has_event_class c2 drafted · lead |
| SMA SI-US W887 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W915 | Sunny Island 4548-US / 6048-US | DSP failure | has_event_class c2 drafted · lead |
| SMA SI-US W936 | Sunny Island 4548-US / 6048-US | Warning via SiCom: General | has_event_class c2 drafted · lead |
| SMA SI-US W937 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery overvoltage | has_event_class c2 drafted · lead |
| SMA SI-US W938 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery undervoltage | has_event_class c2 drafted · lead |
| SMA SI-US W939 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery overtemperature | has_event_class c2 drafted · lead |
| SMA SI-US W940 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery undertemperature | has_event_class c2 drafted · lead |
| SMA SI-US W941 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery overtemperature in charge mode | has_event_class c2 drafted · lead |
| SMA SI-US W942 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Battery undertemperature in charge mode | has_event_class c2 drafted · lead |
| SMA SI-US W943 | Sunny Island 4548-US / 6048-US | Warning via SiCom: battery charging current too high | has_event_class c2 drafted · lead |
| SMA SI-US W944 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W945 | Sunny Island 4548-US / 6048-US | Warning via SiCom: error in the battery | has_event_class c2 drafted · lead |
| SMA SI-US W946 | Sunny Island 4548-US / 6048-US | Warning via SiCom: short circuit | has_event_class c2 drafted · lead |
| SMA SI-US W947 | Sunny Island 4548-US / 6048-US | Warning via SiCom: internal error in battery management | has_event_class c2 drafted · lead |
| SMA SI-US W948 | Sunny Island 4548-US / 6048-US | has_event_class c2 drafted · lead | |
| SMA SI-US W951 | Sunny Island 4548-US / 6048-US | Warning via SiCom: Generator | has_event_class c2 drafted · lead |
| SMA SI-US W953 | Sunny Island 4548-US / 6048-US | Time for external battery management exceeded | has_event_class c2 drafted · lead |
Schneider Electric
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Schneider Electric CL125 074 | Schneider Electric Conext CL125 | Communication event | has_event_class c4 drafted · lead |
| Schneider Electric CL125 078 | Schneider Electric Conext CL125 | PV power event warning | has_event_class c6 verified · fact |
Sungrow
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Sungrow SG-CX-US 220-227 | Sungrow SG36/60CX-US | PVx abnormal | has_event_class c7 drafted · lead |
| Sungrow SG-CX-US 532-547 | Sungrow SG36/60CX-US | String x reverse connection alarm | has_event_class c7 drafted · lead |
| Sungrow SG-CX-US 548-563 | Sungrow SG36/60CX-US | String x output current anomaly | has_event_class c9 drafted · lead |
| Sungrow SG-CX-US 564-571 | Sungrow SG36/60CX-US | String x reverse connection alarm | has_event_class c7 drafted · lead |
| Sungrow SG-CX-US 070 | Sungrow SG36/60CX-US | Fan alarm | has_event_class c9 verified · fact |
| Sungrow SG-CX-US 071 | Sungrow SG36/60CX-US | AC-side SPD alarm | has_event_class c6 drafted · lead |
| Sungrow SG-CX-US 072 | Sungrow SG36/60CX-US | DC-side SPD alarm | has_event_class c5 drafted · lead |
| Sungrow SG-CX-US 078-081 | Sungrow SG36/60CX-US | PVx abnormal | has_event_class c4 drafted · lead |
| Sungrow SG200HX 1470 | Sungrow SG200HX-US | MPPT connection unbalance alarm | has_event_class c3 drafted · lead |
| Sungrow SG200HX 216-218 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 220-233 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 332-363 | Sungrow SG200HX-US | Boost Capacitor Overvoltage Alarm | has_event_class c3 drafted · lead |
| Sungrow SG200HX 432-434 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 500-513 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 514 | Sungrow SG200HX-US | Meter Communication Abnormal Alarm | has_event_class c5 drafted · lead |
| Sungrow SG200HX 515-518 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 532-547 | Sungrow SG200HX-US | PV Reverse Connection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG200HX 548-563 | Sungrow SG200HX-US | PV Abnormal Alarm | has_event_class c8 drafted · lead |
| Sungrow SG200HX 564-579 | Sungrow SG200HX-US | PV Reverse Connection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG200HX 580-595 | Sungrow SG200HX-US | PV Abnormal Alarm | has_event_class c10 drafted · lead |
| Sungrow SG200HX 59 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 635-638 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 70-74 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 75 | Sungrow SG200HX-US | Inverter Parallel Communication Alarm | has_event_class c4 drafted · lead |
| Sungrow SG200HX 76-83 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 84 | Sungrow SG200HX-US | Reverse Connection Alarm of the Meter/CT | has_event_class c6 verified · fact |
| Sungrow SG200HX 89 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 900 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 901 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 910 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 911 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG200HX 996 | Sungrow SG200HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 216-218 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 220-232 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 332-363 | Sungrow SG250HX | Boost Capacitor Overvoltage Alarm | has_event_class c3 drafted · lead |
| Sungrow SG250HX 432-434 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 500-513 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 514 | Sungrow SG250HX | Meter Communi-cation Abnormal Alarm | has_event_class c5 drafted · lead |
| Sungrow SG250HX 515-518 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 532-547 | Sungrow SG250HX | PV Reverse Con-nection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG250HX 548-563 | Sungrow SG250HX | PV Abnormal Alarm | has_event_class c9 drafted · lead |
| Sungrow SG250HX 564-579 | Sungrow SG250HX | PV Reverse Con-nection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG250HX 580-595 | Sungrow SG250HX | PV Abnormal Alarm | has_event_class c9 drafted · lead |
| Sungrow SG250HX 59 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 635-638 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 70-74 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 75 | Sungrow SG250HX | Inverter Parallel Communication Alarm | has_event_class c4 drafted · lead |
| Sungrow SG250HX 76 | Sungrow SG250HX | System Alarm | has_event_class c3 drafted · lead |
| Sungrow SG250HX 77-81 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 82 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 83 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 84 | Sungrow SG250HX | Reverse Connec-tion Alarm of the Meter/CT | has_event_class c6 drafted · lead |
| Sungrow SG250HX 89 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 900 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 901 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 910 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 911 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG250HX 996 | Sungrow SG250HX | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 1470 | Sungrow SG350HX-US | MPPT connection unbalance alarm | has_event_class c3 drafted · lead |
| Sungrow SG350HX 216-218 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 220-233 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 332-363 | Sungrow SG350HX-US | Boost Capacitor Overvoltage Alarm | has_event_class c3 drafted · lead |
| Sungrow SG350HX 432-434 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 500-513 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 514 | Sungrow SG350HX-US | Meter Communication Abnormal Alarm | has_event_class c5 drafted · lead |
| Sungrow SG350HX 515-518 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 532-547 | Sungrow SG350HX-US | PV Reverse Connection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG350HX 548-563 | Sungrow SG350HX-US | PV Abnormal Alarm | has_event_class c8 drafted · lead |
| Sungrow SG350HX 564-579 | Sungrow SG350HX-US | PV Reverse Connection Alarm | has_event_class c6 drafted · lead |
| Sungrow SG350HX 580-595 | Sungrow SG350HX-US | PV Abnormal Alarm | has_event_class c10 drafted · lead |
| Sungrow SG350HX 59 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 635-638 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 70-74 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 75 | Sungrow SG350HX-US | Inverter Parallel Communication Alarm | has_event_class c4 drafted · lead |
| Sungrow SG350HX 76-83 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 84 | Sungrow SG350HX-US | Reverse Connection Alarm of the Meter/CT | has_event_class c6 drafted · lead |
| Sungrow SG350HX 89 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 900 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 901 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 910 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 911 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
| Sungrow SG350HX 996 | Sungrow SG350HX-US | System Alarm | has_event_class c2 drafted · lead |
Yaskawa Solectria
| Code | Family | Shown as | Claim |
|---|---|---|---|
| Yaskawa Solectria PVI-14-20TL Arc Board Error | Solectria PVI 14/20TL | Internal Arc board self-check error | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL EepromErr | Solectria PVI 14/20TL | Incorrect memory reading | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL ExtFanErr | Solectria PVI 14/20TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-14-20TL IntFanErr | Solectria PVI 14/20TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-14-20TL SPICommErr | Solectria PVI 14/20TL | Inverters internal communication failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-14-20TL TempSensorErr | Solectria PVI 14/20TL | Abnormal temperature reading | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R CommErr | Solectria PVI 20/25TL-480-R | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-25TL-R Warn0100 | Solectria PVI 20/25TL-480-R | AC SPD fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R WARN-30 | Solectria PVI 20/25TL-480-R | EepromErr | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Warn0040 | Solectria PVI 20/25TL-480-R | DC SPD fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-25TL-R Warn0050 | Solectria PVI 20/25TL-480-R | TempSensorErr | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL EepromErr | Solectria PVI 23/28/36TL | Incorrect memory reading | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL ExtFanErr | Solectria PVI 23/28/36TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-TL IntFanErr | Solectria PVI 23/28/36TL | has_event_class c2 drafted · lead | |
| Yaskawa Solectria PVI-TL SPICommErr | Solectria PVI 23/28/36TL | Inverter's internal communication failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria PVI-TL TempSensorErr | Solectria PVI 23/28/36TL | Abnormal temperature reading | has_event_class c2 drafted · lead |
| Yaskawa Solectria SGI-XTM Filter Cont. Err | Solectria SGI 500/750XTM | has_event_class c4 verified · fact | |
| Yaskawa Solectria SGI-XTM MOV Fault | Solectria SGI 500/750XTM | has_event_class c4 drafted · lead | |
| Yaskawa Solectria SGI-XTM Power Derated | Solectria SGI 500/750XTM | has_event_class c3 verified · fact | |
| Yaskawa Solectria SGI-XTM RCM Warn | Solectria SGI 500/750XTM | has_event_class c3 verified · fact | |
| Yaskawa Solectria XGI-1500-1MW WARN-1 | Yaskawa Solectria XGI 1500-1MW | Internal Over Current/ Over Voltage | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-10 | Yaskawa Solectria XGI 1500-1MW | AC Very Low Voltage 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-11 | Yaskawa Solectria XGI 1500-1MW | AC Extremely Low Voltage 3 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-12 | Yaskawa Solectria XGI 1500-1MW | AC High Voltage 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-13 | Yaskawa Solectria XGI 1500-1MW | AC Very High Voltage 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-2 | Yaskawa Solectria XGI 1500-1MW | Phase Lock Loop Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-25 | Yaskawa Solectria XGI 1500-1MW | Communication 1 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-26 | Yaskawa Solectria XGI 1500-1MW | Communication 2 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-27 | Yaskawa Solectria XGI 1500-1MW | Communication 3 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-28 | Yaskawa Solectria XGI 1500-1MW | Network Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-29 | Yaskawa Solectria XGI 1500-1MW | Software Update Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-3 | Yaskawa Solectria XGI 1500-1MW | Islanding Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-30 | Yaskawa Solectria XGI 1500-1MW | Unauthorized Network Access | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-31 | Yaskawa Solectria XGI 1500-1MW | Invalid Configuration Request | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-32 | Yaskawa Solectria XGI 1500-1MW | has_event_class c2 drafted · lead | |
| Yaskawa Solectria XGI-1500-1MW WARN-4 | Yaskawa Solectria XGI 1500-1MW | Open Phase Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-5 | Yaskawa Solectria XGI 1500-1MW | AC Low Frequency 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-6 | Yaskawa Solectria XGI 1500-1MW | AC Very Low Frequency 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-7 | Yaskawa Solectria XGI 1500-1MW | AC High Frequency 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-8 | Yaskawa Solectria XGI 1500-1MW | AC Very High Frequency 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-1MW WARN-9 | Yaskawa Solectria XGI 1500-1MW | AC Low Voltage 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-1 | Yaskawa Solectria XGI 1500-DCG | Internal Over Current/ Over Voltage | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-10 | Yaskawa Solectria XGI 1500-DCG | AC Very Low Voltage 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-11 | Yaskawa Solectria XGI 1500-DCG | AC Extremely Low Voltage 3 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-12 | Yaskawa Solectria XGI 1500-DCG | AC High Voltage 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-13 | Yaskawa Solectria XGI 1500-DCG | AC Very High Voltage 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-2 | Yaskawa Solectria XGI 1500-DCG | Phase Lock Loop Failure | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-25 | Yaskawa Solectria XGI 1500-DCG | Communication 1 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-26 | Yaskawa Solectria XGI 1500-DCG | Communication 2 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-27 | Yaskawa Solectria XGI 1500-DCG | Communication 3 Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-28 | Yaskawa Solectria XGI 1500-DCG | Network Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-29 | Yaskawa Solectria XGI 1500-DCG | Software Update Fault | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-3 | Yaskawa Solectria XGI 1500-DCG | Islanding Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-30 | Yaskawa Solectria XGI 1500-DCG | Unauthorized Network Access | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-31 | Yaskawa Solectria XGI 1500-DCG | Invalid Configuration Request | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-32 | Yaskawa Solectria XGI 1500-DCG | has_event_class c2 drafted · lead | |
| Yaskawa Solectria XGI-1500-DCG WARN-4 | Yaskawa Solectria XGI 1500-DCG | Open Phase Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-5 | Yaskawa Solectria XGI 1500-DCG | AC Low Frequency 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-6 | Yaskawa Solectria XGI 1500-DCG | AC Very Low Frequency 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-7 | Yaskawa Solectria XGI 1500-DCG | AC High Frequency 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-8 | Yaskawa Solectria XGI 1500-DCG | AC Very High Frequency 2 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500-DCG WARN-9 | Yaskawa Solectria XGI 1500-DCG | AC Low Voltage 1 Detected | has_event_class c2 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-1 | Yaskawa Solectria XGI 1500 | Internal Over Current/ Over Voltage | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-10 | Yaskawa Solectria XGI 1500 | AC Very Low Voltage 2 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-11 | Yaskawa Solectria XGI 1500 | AC Extremely Low Voltage 3 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-12 | Yaskawa Solectria XGI 1500 | AC High Voltage 1 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-13 | Yaskawa Solectria XGI 1500 | AC Very High Voltage 2 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-2 | Yaskawa Solectria XGI 1500 | Phase Lock Loop Failure | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-25 | Yaskawa Solectria XGI 1500 | Communication 1 Fault | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-26 | Yaskawa Solectria XGI 1500 | Communication 2 Fault | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-27 | Yaskawa Solectria XGI 1500 | Communication 3 Fault | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-28 | Yaskawa Solectria XGI 1500 | Network Fault | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-29 | Yaskawa Solectria XGI 1500 | Software Update Fault | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-3 | Yaskawa Solectria XGI 1500 | Islanding Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-30 | Yaskawa Solectria XGI 1500 | Unauthorized Network Access | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-31 | Yaskawa Solectria XGI 1500 | Invalid Configuration Request | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-32 | Yaskawa Solectria XGI 1500 | has_event_class c4 drafted · lead | |
| Yaskawa Solectria XGI-1500 WARN-4 | Yaskawa Solectria XGI 1500 | Open Phase Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-5 | Yaskawa Solectria XGI 1500 | AC Low Frequency 1 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-6 | Yaskawa Solectria XGI 1500 | AC Very Low Frequency 2 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-7 | Yaskawa Solectria XGI 1500 | AC High Frequency 1 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-8 | Yaskawa Solectria XGI 1500 | AC Very High Frequency 2 Detected | has_event_class c4 drafted · lead |
| Yaskawa Solectria XGI-1500 WARN-9 | Yaskawa Solectria XGI 1500 | AC Low Voltage 1 Detected | has_event_class c4 drafted · lead |