Fault codes › Yaskawa Solectria › Solectria PVI 14/20TL
Yaskawa Solectria PVI-14-20TL IntFanErr
- Code
IntFanErr
- Vendor severity
- Alarm
- Page
- 47
- ID
fc:yaskawa-solectria-pvi-14-20tl-intfanerr
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-14-20tl-intfanerr
- Status
- active
- Also known as
- IntFanErr, intfanerr, Yaskawa Solectria IntFanErr
- Category
- Inverters
Decoded
Reports fan fault alarm; may indicate fan failure; look at cooling fan; do: inverter restart, contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- PVI 14-20TL IOM DOCR-070351-G — Yaskawa Solectria Solar · page 47 drafted · lead
tbl=10.r9 h=dd6e1c42439a
tbl=10.r10 h=723ace76c015
tbl=10.r11 h=2bf91b0d7393
tbl=10.r12 h=de62313dc809
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-60-TL W010, ABB / FIMER TRIO-20.0-27.6-TL W010, ABB / FIMER UNO-DM-3.3-5.0-PLUS W010, ABB / FIMER UNO-DM-6.0-PLUS W010
- CPS
- CPS SCA25KTL-208 ExtFanErr, CPS SCA25KTL-480 ExtFanErr, CPS SCA25KTL-480 IntFanErr, CPS SCA50-100K-T Warn0000, CPS SCA50-100K-T Warn0010, CPS SCH100-125KTL ExtFanErr, CPS SCH100-125KTL IntFanErr, CPS SCH125KTL-AIO ExtFanErr, CPS SCH200-250K-T ExtFanErr, CPS SCH200-250K-T IntFanErr, CPS SCH275KTL ExtFanErr, CPS SCH275KTL IntFanErr, CPS SCH350KTL ExtFanErr, CPS SCH350KTL IntFanErr, CPS SCH350KTL Warn0080
- Canadian Solar
- Canadian Solar 23-28KTL-CT ExtFanErr
- Fronius
- Fronius Symo 326, Fronius Symo 327
- KACO new energy
- KACO new energy blueplanet TL3 187, KACO new energy blueplanet TL3 70, KACO new energy blueplanet TL3 71, KACO new energy blueplanet TL3 72
- SMA
- SMA STP-TL-US 7508, SMA SC-CP-XT 7507
- Schneider Electric
- Schneider Electric CL125 070
- Solis
- Solis S6-EH2P Fan Alarm, Solis S6-EH3P30-60K Fan Alarm, Solis S6-EH3P75-150K Fan Alarm
- Sungrow
- Sungrow SG-CX-US 070
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL ExtFanErr, Yaskawa Solectria PVI-25TL-R IntFanErr, Yaskawa Solectria PVI-TL ExtFanErr, Yaskawa Solectria PVI-TL IntFanErr
Same code in other families
Claims
defined_in
c1 drafted · lead
PVI 14-20TL IOM DOCR-070351-G
has_event_class
c2 drafted · lead
Warning (device continues, a condition is flagged)
from the Type column
reports
c3 drafted · lead
Fan fault alarm
indicates
c4 drafted · lead
Fan failure
affects
c5 drafted · lead
Cooling fan
mitigated_by
c6 drafted · lead
Inverter restart
Used when the alarm does not clear on its own.
c7 drafted · lead
Contact manufacturer service
Final escalation if the alarm persists after restart.
has_recovery
c8 drafted · lead
Auto-reset (clears by itself)
Watch for automatic clearing first; then power cycle; then contact service.
review note: support check: partial - The row says to observe for automatic clearing first, but power cycling and service are also required if it does…
applies_to
c9 drafted · lead
Solectria PVI 14-20TL
Data