Fault codes › CPS › CPS SCH275KTL-DO/US-800
CPS SCH275KTL ExtFanErr
- Code
ExtFanErr
- Vendor severity
- Alarm
- Page
- 70
- ID
fc:chint-sch-275ktl-extfanerr
- IRI
https://solarlattice.org/kb/fc/chint-sch-275ktl-extfanerr
- Status
- active
- Also known as
- ExtFanErr, extfanerr, CPS ExtFanErr
- Category
- Inverters
Decoded
Reports fan fault alarm; may indicate fan failure; look at cooling fan; confirm with visual inspection; do: clear ventilation blockage.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-60-TL W010, ABB / FIMER TRIO-20.0-27.6-TL W010, ABB / FIMER UNO-DM-3.3-5.0-PLUS W010, ABB / FIMER UNO-DM-6.0-PLUS W010
- CPS
- CPS SCA25KTL-208 ExtFanErr, CPS SCA25KTL-480 ExtFanErr, CPS SCA25KTL-480 IntFanErr, CPS SCA50-100K-T Warn0000, CPS SCA50-100K-T Warn0010, CPS SCH100-125KTL ExtFanErr, CPS SCH100-125KTL IntFanErr, CPS SCH125KTL-AIO ExtFanErr, CPS SCH200-250K-T ExtFanErr, CPS SCH200-250K-T IntFanErr, CPS SCH275KTL IntFanErr, CPS SCH350KTL ExtFanErr, CPS SCH350KTL IntFanErr, CPS SCH350KTL Warn0080
- Canadian Solar
- Canadian Solar 23-28KTL-CT ExtFanErr
- Fronius
- Fronius Symo 326, Fronius Symo 327
- KACO new energy
- KACO new energy blueplanet TL3 187, KACO new energy blueplanet TL3 70, KACO new energy blueplanet TL3 71, KACO new energy blueplanet TL3 72
- SMA
- SMA STP-TL-US 7508, SMA SC-CP-XT 7507
- Schneider Electric
- Schneider Electric CL125 070
- Solis
- Solis S6-EH2P Fan Alarm, Solis S6-EH3P30-60K Fan Alarm, Solis S6-EH3P75-150K Fan Alarm
- Sungrow
- Sungrow SG-CX-US 070
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL ExtFanErr, Yaskawa Solectria PVI-14-20TL IntFanErr, Yaskawa Solectria PVI-25TL-R IntFanErr, Yaskawa Solectria PVI-TL ExtFanErr, Yaskawa Solectria PVI-TL IntFanErr
Same code in other families
Claims
defined_in
c1 drafted · lead
CPS SCH275KTL-DO-US-800 V2 User Manual Rev 1.7
has_event_class
c2 drafted · lead
Warning (device continues, a condition is flagged)
from the table header
reports
c3 drafted · lead
Fan fault alarm
indicates
c4 drafted · lead
Fan failure
affects
c5 drafted · lead
Cooling fan
Blocked fan, expired fan life or poor fan connector contact
detected_by
c6 drafted · lead
Visual inspection
Inspect fan blades for foreign objects
mitigated_by
c7 drafted · lead
Clear ventilation blockage
Remove foreign objects from fan blades
review note: support check: partial - Checking for foreign objects on fan blades is recommended, but removal and clearing the blockage are only implied.
has_recovery
c8 drafted · lead
Auto-reset (clears by itself)
First observe for self-clearing; then blade check, reboot, then service
applies_to
c9 drafted · lead
CPS SCH275KTL-DO/US-800