Clear ventilation blockage
Clearing a ventilation blockage is a corrective step for an inverter that trips on over-temperature protection (TempOver). The alarm means the ambient or internal temperature is too high. Check whether the air inlet or the cooling fan is blocked. Also confirm that the outside temperature is within the inverter's rated operating range and that the installation location is suitable. After you clear the blockage, watch the inverter for 30 minutes to see if the alarm clears by itself. If it does not, contact the manufacturer's after-sales service. To keep air moving, leave clear space around the inverter, especially at the air intake side and above the unit. If the inverter sits in a vault or closet, provide outside ventilation. If the ambient air is outside the normal range, the inverter will reduce its power on its own or may shut down to protect itself. As preventive maintenance, clean inverter filters and test the ventilation system twice a year, and replace the filters on a set schedule. Poor ventilation can void an inverter's warranty, so blocked airflow is also a warranty risk.
<!-- review notes
- sentence 6: support check: partial - The plan lists cleaning filters and functional ventilation test as semi-annual and filter replacement every 2 years, but 'twice a year' is an interpretation of SA and the replacement schedule is stated as 2yr. -->
Referenced by
- Inverter cooling
related_toc10 - Thermal derating
related_toc8 - Canadian Solar 185-255K OV-TEM
mitigated_byc6 - Canadian Solar 23-28KTL-CT ExtFanErr
mitigated_byc7 - Canadian Solar 23-28KTL-CT TempOver
mitigated_byc6 - Canadian Solar 25-40K-T480GL01 OV-TEM
mitigated_byc6 - Canadian Solar 50-66K-T480GL01 OV-TEM
mitigated_byc6 - Canadian Solar 75-100K-T480GL02 OV-TEM
mitigated_byc6 - CPS SCA25KTL-208 ExtFanErr
mitigated_byc7 - CPS SCA25KTL-208 TempOver
mitigated_byc5 - CPS SCA25KTL-480 ExtFanErr
mitigated_byc6 - CPS SCA25KTL-480 IntFanErr
mitigated_byc5 - CPS SCA25KTL-480 TempOver
mitigated_byc4 - CPS SCA36KTL TempOver
mitigated_byc6 - CPS SCA50-100K-T Protect0140
mitigated_byc6 - CPS SCA50-100K-T Warn0000
mitigated_byc7 - CPS SCA50-60KTL TempOver
mitigated_byc6 - CPS SCH100-125KTL ExtFanErr
mitigated_byc7 - CPS SCH100-125KTL IntFanErr
mitigated_byc6 - CPS SCH100-125KTL TempOver
mitigated_byc5 - CPS SCH125KTL-AIO ExtFanErr
mitigated_byc7 - CPS SCH125KTL-AIO TempOver
mitigated_byc5 - CPS SCH200-250K-T ExtFanErr
mitigated_byc6 - CPS SCH200-250K-T IntFanErr
mitigated_byc5 - CPS SCH200-250K-T TempOver
mitigated_byc4 - CPS SCH275KTL ExtFanErr
mitigated_byc7 - CPS SCH275KTL IntFanErr
mitigated_byc6 - CPS SCH275KTL TempOver
mitigated_byc5 - CPS SCH350KTL ExtFanErr
mitigated_byc6 - CPS SCH350KTL IntFanErr
mitigated_byc5 - CPS SCH350KTL TempOver
mitigated_byc4 - Fronius Galvo 303
mitigated_byc4 - Fronius Galvo 517
mitigated_byc7 - Fronius Primo 303
mitigated_byc4 - Fronius Primo 517
mitigated_byc7 - Fronius Symo 303
mitigated_byc4 - Fronius Symo 517
mitigated_byc7 - KACO new energy blueplanet TL3 10
mitigated_byc5 - KACO new energy blueplanet TL3 11
mitigated_byc5 - KACO new energy blueplanet TL3 58
mitigated_byc7 - Schneider Electric CL125 037
mitigated_byc7 - SMA SB-US-40 8003
mitigated_byc6 - SMA SB-US-41 8003
mitigated_byc6 - SMA SBSE-US-50 6501
mitigated_byc8 - SMA SBSE-US-50 6502
mitigated_byc5 - SMA SBSE-US-50 6509
mitigated_byc6 - SMA SBSE-US-50 6511
mitigated_byc4 - SMA SBSE-US-50 8003
mitigated_byc6 - SMA PEAK3-US 6501
mitigated_byc8 - SMA PEAK3-US 6511
mitigated_byc4 - SMA PEAK3-US 8003
mitigated_byc6 - SMA CORE1-US 6502
mitigated_byc7 - SMA CORE1-US 8003
mitigated_byc7 - SMA STP-TL-US 6501-6511
mitigated_byc4 - SMA STP-TL-US 7508
mitigated_byc5 - SMA STP-TL-US 8001
mitigated_byc6 - SMA STP-X-US 6501
mitigated_byc8 - SMA STP-X-US 6511
mitigated_byc4 - SMA SC-CP-XT 6501
mitigated_byc8 - SMA SC-CP-XT 6502
mitigated_byc5 - SMA SC-CP-XT 7501
mitigated_byc5 - SMA SC-CP-XT 7502
mitigated_byc5 - SMA SC-CP-XT 7503
mitigated_byc4 - SMA SC-CP-XT 7507
mitigated_byc4 - SMA SC-CP-XT 7510
mitigated_byc6 - Solis 1P-4G-US OV-TEM
mitigated_byc6 - Solis 3P-5G-US OV-TEM
mitigated_byc5 - Solis RHI-1P-HV OV-TEM
mitigated_byc5 - Solis S5-GC OV-TEM
mitigated_byc5 - Solis S6-EH1P OV-TEM
mitigated_byc5 - Solis S6-EH2P OV-TEM
mitigated_byc5 - Solis S6-EH3P30-60K OV-TEM
mitigated_byc6 - Solis S6-EH3P75-150K OV-TEM
mitigated_byc5 - Solis S6-GC OV-TEM
mitigated_byc6 - Solis S6-GU OV-TEM
mitigated_byc5 - Sungrow SG-CX-US 036
mitigated_byc7 - Sungrow SG-CX-US 037
mitigated_byc8 - Sungrow SG-CX-US 070
mitigated_byc7 - Sungrow SG200HX 036
mitigated_byc6 - Sungrow SG200HX 037
mitigated_byc7 - Sungrow SG250HX 36
mitigated_byc5 - Sungrow SG250HX 37
mitigated_byc6 - Sungrow SG350HX 036
mitigated_byc6 - Sungrow SG350HX 037
mitigated_byc7 - Yaskawa Solectria PVI-14-20TL ExtFanErr
mitigated_byc6 - Yaskawa Solectria PVI-14-20TL OverTemp
mitigated_byc5 - Yaskawa Solectria PVI-25TL-R TempOver
mitigated_byc5 - Yaskawa Solectria PVI-TL ExtFanErr
mitigated_byc6 - Yaskawa Solectria PVI-TL OverTemp
mitigated_byc5 - Yaskawa Solectria SGI-XTM Current Limit
mitigated_byc8 - Yaskawa Solectria XGI-1500-1MW CRIT-6
mitigated_byc6 - Yaskawa Solectria XGI-1500 CRIT-6
mitigated_byc8 - Yaskawa Solectria XGI-1500-DCG CRIT-6
mitigated_byc6 - Fan failure
mitigated_byc12 - Inverter Overheating
mitigated_byc12