Solar Lattice

Fault codes › Schneider Electric › Schneider Electric Conext CL125

Schneider Electric CL125 070

Code
070
Shown as
Fan event
Page
129
ID
fc:schneider-electric-conext-cl125-70
IRI
https://solarlattice.org/kb/fc/schneider-electric-conext-cl125-70
Status
active
Also known as
070, 70, Schneider Electric 070, Fan event
Category
Inverters
Class fault drafted · lead
Production not stated
Clears needs service drafted · lead

Decoded

Reports fan fault alarm; may indicate fan failure; look at cooling fan; do: fan replacement.

What can be behind Fan fault alarm

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-60-TL W010, ABB / FIMER TRIO-20.0-27.6-TL W010, ABB / FIMER UNO-DM-3.3-5.0-PLUS W010, ABB / FIMER UNO-DM-6.0-PLUS W010
CPS
CPS SCA25KTL-208 ExtFanErr, CPS SCA25KTL-480 ExtFanErr, CPS SCA25KTL-480 IntFanErr, CPS SCA50-100K-T Warn0000, CPS SCA50-100K-T Warn0010, CPS SCH100-125KTL ExtFanErr, CPS SCH100-125KTL IntFanErr, CPS SCH125KTL-AIO ExtFanErr, CPS SCH200-250K-T ExtFanErr, CPS SCH200-250K-T IntFanErr, CPS SCH275KTL ExtFanErr, CPS SCH275KTL IntFanErr, CPS SCH350KTL ExtFanErr, CPS SCH350KTL IntFanErr, CPS SCH350KTL Warn0080
Canadian Solar
Canadian Solar 23-28KTL-CT ExtFanErr
Fronius
Fronius Symo 326, Fronius Symo 327
KACO new energy
KACO new energy blueplanet TL3 187, KACO new energy blueplanet TL3 70, KACO new energy blueplanet TL3 71, KACO new energy blueplanet TL3 72
SMA
SMA STP-TL-US 7508, SMA SC-CP-XT 7507
Solis
Solis S6-EH2P Fan Alarm, Solis S6-EH3P30-60K Fan Alarm, Solis S6-EH3P75-150K Fan Alarm
Sungrow
Sungrow SG-CX-US 070
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL ExtFanErr, Yaskawa Solectria PVI-14-20TL IntFanErr, Yaskawa Solectria PVI-25TL-R IntFanErr, Yaskawa Solectria PVI-TL ExtFanErr, Yaskawa Solectria PVI-TL IntFanErr

Claims

defined_in

c1 drafted · lead Conext CL125 Owners Guide 975-0793 RevA

c2 drafted · lead Conext CL125 Modbus App Note

reports

c3 drafted · lead Fan fault alarm

indicates

c4 drafted · lead Fan failure

affects

c5 drafted · lead Cooling fan

mitigated_by

c6 drafted · lead Fan replacement

has_event_class

c7 drafted · lead Fault (device stops or needs intervention)

Fan must be replaced, so intervention is needed.

review note: support check: partial - Intervention needed (stop inverter, replace fan) is stated, but fault classification is not explicit; it is more service-required.

has_recovery

c8 drafted · lead Service required

Fan replacement; the app's fan status shows which fan is affected.