Solar Lattice

Product

Schneider Electric Conext CL125

ID
prod:schneider-electric-conext-cl125
IRI
https://solarlattice.org/kb/prod/schneider-electric-conext-cl125
Status
active
Also known as
Conext CL125, Conext CL 125, CL 125, CL 125 A, CL 125 E, Conext CL125A, Conext CL125E, PVSCL125A, PVSCL125E, Conext CL Inverter
Category
Inverters
Make
schneider-electric
Product level
family

The Conext CL125 is a three-phase string inverter family from Schneider Electric. It comes as the CL125E for IEC markets and the CL125A for North America. Both versions are rated at 125 kW and 125 kVA at nominal AC voltage. The CL125A is built for 1500 VDC floating PV systems and has a single PV input. On the CL125A, full-power MPPT runs from 860 V to 1250 V, and the AC output is 600 V three-phase in star or delta (3P+PE). Peak efficiency is 98.8% for both versions. The CL125E has a European efficiency of 98.7% and the CL125A a CEC efficiency of 98.5%. Power factor can be set anywhere from 0.8 capacitive to 0.8 inductive. For communications it uses Modbus over two RS-485 ports that can be daisy-chained, and it is SunSpec compatible and certified. Local setup is through a front LED panel and the eConfigure CL125 app over Bluetooth 4.0. Firmware upgrades and configuration are done locally with the eConfigure app or the Conext CL EasyConfig tool. Many settings need a Level 2 user access account, which you request from a Schneider Electric representative. The electronics enclosure is rated Type 4X on the CL125A and IP 65 on the CL125E.

<!-- review notes

Claims

manufactured_by

c1 verified · fact Schneider Electric

verified by: review-workflowverified on: 2026-10-24

rated_power

c2 drafted · lead nominal 125 KiloW

Conditions: Maximum AC output active power at PF=1 and nominal AC voltage; CL125E (IEC) and CL125A (NA)

c3 drafted · lead nominal 125 KiloV-A

Conditions: Maximum continuous apparent power at nominal AC voltage; CL125E (IEC) and CL125A (NA)

c4 drafted · lead nominal 125 KiloW

Conditions: Conext CL125A, 1500 VDC systems (solution guide key specifications)

mppt_voltage_range

c5 drafted · lead 860–1250 V

Conditions: Full-power MPPT voltage range, Conext CL125A

c6 drafted · lead 860–1450 V

Conditions: DC operating voltage range, Conext CL125A

nominal_voltage

c7 drafted · lead nominal 600 V

Conditions: Three-phase AC output, star or delta (3P+PE), Conext CL125A

efficiency

c8 drafted · lead nominal 98.8 PERCENT

Conditions: Peak efficiency, CL125E (IEC) and CL125A (NA)

review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)

c9 drafted · lead nominal 98.7 PERCENT

Conditions: European efficiency, Conext CL125E (IEC)

review note: possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)

c10 drafted · lead nominal 98.5 PERCENT

Conditions: CEC efficiency, Conext CL125A (NA)

review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions)

uses_protocol

c11 drafted · lead RS-485

Two RS-485 ports (RS-485_1 and RS-485_2) supporting daisy-chain wiring

c12 drafted · lead Modbus

c13 drafted · lead SunSpec Modbus

Stated as SunSpec compatible and certified

c14 drafted · lead Bluetooth

Bluetooth 4.0 link to the eConfigure CL125 app

implements

c15 drafted · lead Maximum power point tracking

Single PV input; MPPT efficiency stated above 99% (static 99.5%, dynamic 99%)

review note: support check: partial - MPPT efficiency, MPPT voltage and single PV input are stated, though MPPT as a function is only implied.

c16 drafted · lead Constant power factor mode

Power factor adjustable from 0.8 capacitive to 0.8 inductive

review note: support check: partial - PF adjustment range is stated, but a constant power factor mode is not explicitly named.

compatible_with

c17 drafted · lead Ungrounded PV array

Conditions: Designed for 1500 V floating PV systems

c18 drafted · lead 600 V three-phase delta service proposed

Conditions: 600 V three-phase delta AC output wiring (3P+PE), Conext CL125A

requires

c19 drafted · lead Level 2 user access proposed

Conditions: Many settings; account requested through a Schneider Electric representative

c20 drafted · lead eConfigure CL125 app proposed

Conditions: Local configuration and firmware upgrade (alternatively the Conext CL EasyConfig tool)

review note: support check: partial - App is listed for local configuration and firmware upgrade alongside EasyConfig, but 'requires' is overstated since the alternative exists.

Referenced by