Fault codes › Schneider Electric › Schneider Electric Conext CL125
Schneider Electric CL125 028
- Code
028
- Shown as
- PV reverse connection is detected.
- Page
- 126
- ID
fc:schneider-electric-conext-cl125-28
- IRI
https://solarlattice.org/kb/fc/schneider-electric-conext-cl125-28
- Status
- active
- Also known as
- 028, 28, Schneider Electric 028, PV reverse connection is detected.
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports reverse polarity; look at DC cable, PV input terminal; do: DC wiring check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E046, ABB / FIMER PVS-60-TL E046, ABB / FIMER TRIO-20.0-27.6-TL E046, ABB / FIMER UNO-DM-3.3-5.0-PLUS E046, ABB / FIMER UNO-DM-6.0-PLUS E046
- CPS
- CPS SCA25KTL-208 PVxReverse, CPS SCA25KTL-480 PV Reverse, CPS SCA36KTL PVxReverse, CPS SCA50-100K-T Protect0350, CPS SCA50-100K-T Protect0410, CPS SCA50-100K-T Protect0430, CPS SCA50-100K-T Protect0810, CPS SCA50-100K-T Protect0840, CPS SCA50-100K-T Protect0870, CPS SCA50-60KTL PVxReverse, CPS SCH100-125KTL PV Reverse, CPS SCH125KTL-AIO PV Reverse, CPS SCH350KTL Reverse PVx electrode
- Canadian Solar
- Canadian Solar 125K-T600GL02 Reve-DC, Canadian Solar 185-255K Reve-DC, Canadian Solar 23-28KTL-CT PV1 (2) Reverse, Canadian Solar 75-100K-T480GL02 Reve-DC
- Fronius
- Fronius Symo 311
- Huawei
- Huawei SUN2000-100KTL-USH0 2011, Huawei SUN2000-25-30KTL-US 120-125, Huawei SUN2000-45KTL-US-HV-D0 120-127
- SMA
- SMA SB-US-40 6803, SMA SB-US-40 6903, SMA SB-US-40 8503, SMA SB-US-41 6803, SMA SB-US-41 6903, SMA SB-US-41 8503, SMA SBSE-US-50 4013, SMA SBSE-US-50 4014, SMA SBSE-US-50 4015, SMA SBSE-US-50 4016, SMA SBSE-US-50 4017, SMA SBSE-US-50 8503, SMA SBSE-US-50 9342, SMA SC-CP-XT 4003, SMA SI-US W851, SMA SI-US W861, SMA SI-US W871, SMA SI-US W881
- Solis
- Solis 3P-5G-US Reve-DC, Solis S5-GC Reve-DC, Solis S6-GC Reve-DC, Solis S6-GU Reve-DC
- Sungrow
- Sungrow SG-CX-US 448-471, Sungrow SG-CX-US 532-547, Sungrow SG-CX-US 564-571, Sungrow SG200HX 208, Sungrow SG200HX 212, Sungrow SG200HX 264-283, Sungrow SG200HX 28, Sungrow SG200HX 29, Sungrow SG200HX 448-479, Sungrow SG200HX 532-547, Sungrow SG200HX 564-579, Sungrow SG250HX 208, Sungrow SG250HX 212, Sungrow SG250HX 264-283, Sungrow SG250HX 28, Sungrow SG250HX 29, Sungrow SG250HX 448-479, Sungrow SG250HX 532-547, Sungrow SG250HX 564-579, Sungrow SG350HX 208, Sungrow SG350HX 212, Sungrow SG350HX 264-283, Sungrow SG350HX 28, Sungrow SG350HX 29, Sungrow SG350HX 448-479, Sungrow SG350HX 532-547, Sungrow SG350HX 564-579
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL PV1 (2) Reverse, Yaskawa Solectria PVI-25TL-R PV Reverse, Yaskawa Solectria PVI-TL PV1 (2) Reverse
Claims
defined_in
c1 drafted · lead
Conext CL125 Owners Guide 975-0793 RevA
c2 drafted · lead
Conext CL125 Modbus App Note
reports
c3 drafted · lead
Reverse polarity
affects
c4 drafted · lead
DC cable
review note: support check: partial - PV cables are mentioned in the solution, but the event affecting a DC cable is only implied.
c5 drafted · lead
PV input terminal
mitigated_by
c6 drafted · lead
DC wiring check
applies_to
c7 drafted · lead
Schneider Electric Conext CL125
Data