Fault codes › Yaskawa Solectria › Solectria PVI 23/28/36TL
Yaskawa Solectria PVI-TL PV1 (2) Reverse
- Code
PV1 (2) Reverse
- Shown as
- DC inputs connected with incorrect polarities
- Vendor severity
- Protection
- Page
- 54
- ID
fc:yaskawa-solectria-pvi-23-36tl-pv12reverse
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-23-36tl-pv12reverse
- Status
- active
- Also known as
- PV1 (2) Reverse, pv12reverse, Yaskawa Solectria PV1 (2) Reverse, DC inputs connected with incorrect polarities
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Clears
not stated
Decoded
Reports reverse polarity; confirm with string polarity measurement; do: string polarity correction, contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- PVI 23-28TL — Yaskawa Solectria Solar · page 54 drafted · lead
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E046, ABB / FIMER PVS-60-TL E046, ABB / FIMER TRIO-20.0-27.6-TL E046, ABB / FIMER UNO-DM-3.3-5.0-PLUS E046, ABB / FIMER UNO-DM-6.0-PLUS E046
- CPS
- CPS SCA25KTL-208 PVxReverse, CPS SCA25KTL-480 PV Reverse, CPS SCA36KTL PVxReverse, CPS SCA50-100K-T Protect0350, CPS SCA50-100K-T Protect0410, CPS SCA50-100K-T Protect0430, CPS SCA50-100K-T Protect0810, CPS SCA50-100K-T Protect0840, CPS SCA50-100K-T Protect0870, CPS SCA50-60KTL PVxReverse, CPS SCH100-125KTL PV Reverse, CPS SCH125KTL-AIO PV Reverse, CPS SCH350KTL Reverse PVx electrode
- Canadian Solar
- Canadian Solar 125K-T600GL02 Reve-DC, Canadian Solar 185-255K Reve-DC, Canadian Solar 23-28KTL-CT PV1 (2) Reverse, Canadian Solar 75-100K-T480GL02 Reve-DC
- Fronius
- Fronius Symo 311
- Huawei
- Huawei SUN2000-100KTL-USH0 2011, Huawei SUN2000-25-30KTL-US 120-125, Huawei SUN2000-45KTL-US-HV-D0 120-127
- SMA
- SMA SB-US-40 6803, SMA SB-US-40 6903, SMA SB-US-40 8503, SMA SB-US-41 6803, SMA SB-US-41 6903, SMA SB-US-41 8503, SMA SBSE-US-50 4013, SMA SBSE-US-50 4014, SMA SBSE-US-50 4015, SMA SBSE-US-50 4016, SMA SBSE-US-50 4017, SMA SBSE-US-50 8503, SMA SBSE-US-50 9342, SMA SC-CP-XT 4003, SMA SI-US W851, SMA SI-US W861, SMA SI-US W871, SMA SI-US W881
- Schneider Electric
- Schneider Electric CL125 028
- Solis
- Solis 3P-5G-US Reve-DC, Solis S5-GC Reve-DC, Solis S6-GC Reve-DC, Solis S6-GU Reve-DC
- Sungrow
- Sungrow SG-CX-US 448-471, Sungrow SG-CX-US 532-547, Sungrow SG-CX-US 564-571, Sungrow SG200HX 208, Sungrow SG200HX 212, Sungrow SG200HX 264-283, Sungrow SG200HX 28, Sungrow SG200HX 29, Sungrow SG200HX 448-479, Sungrow SG200HX 532-547, Sungrow SG200HX 564-579, Sungrow SG250HX 208, Sungrow SG250HX 212, Sungrow SG250HX 264-283, Sungrow SG250HX 28, Sungrow SG250HX 29, Sungrow SG250HX 448-479, Sungrow SG250HX 532-547, Sungrow SG250HX 564-579, Sungrow SG350HX 208, Sungrow SG350HX 212, Sungrow SG350HX 264-283, Sungrow SG350HX 28, Sungrow SG350HX 29, Sungrow SG350HX 448-479, Sungrow SG350HX 532-547, Sungrow SG350HX 564-579
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL PV1 (2) Reverse, Yaskawa Solectria PVI-25TL-R PV Reverse
Same code in other families
Claims
defined_in
c1 drafted · lead
PVI 23-28TL
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 drafted · lead
Reverse polarity
detected_by
c4 drafted · lead
String polarity measurement
review note: support check: partial - Passages say verify DC polarity but do not state detection by polarity measurement.
mitigated_by
c5 drafted · lead
String polarity correction
c6 drafted · lead
Contact manufacturer service
Only if the error persists with correct polarity.
applies_to
c7 drafted · lead
Solectria PVI 23-36TL
Data