Yaskawa Solectria fault codes

Solectria PVI 14/20TL

CodeShown asClassProductionClearsReportsPage
Arc Board ErrorInternal Arc board self-check error warning by itself Self-test failure 48
Arc Protect fault stops by itself Arc fault detected 51
EepromErrIncorrect memory reading warning by itself Internal memory error 48
ExtFanErr warning by itself Fan fault alarm 48
GFCI.ErrDC leakage current is above recommend value fault by itself High leakage current 51
GridF.OutLim fault by itself Grid frequency out of range 50
GridV.OutLimGrid voltage exceeds the specified range fault by itself Grid voltage out of range 49
IntFanErr warning by itself Fan fault alarm 47
IntFaultA~OInternal noncritical fault within the inverter fault by itself Internal device fault 51
IntProtectA~ZInternal problem within the inverter fault stops by itself Internal device fault 51
OverTemp fault by itself Inverter overtemperature 49
PV1 (2) ReverseDC inputs connected with incorrect polarities fault Reverse polarity 50
PV1 (2) VoltOverDC input voltage exceeds the specified value fault by itself DC overvoltage 50
SPICommErrInverters internal communication failure warning by itself Internal communication failure 47
TempSensorErrAbnormal temperature reading warning after a manual reset Abnormal temperature reading 47

Solectria PVI 20/25TL-480-R

CodeShown asClassProductionClearsReportsPage
Arc Protect stops by itself Arc fault detected 82
CommErr warning by itself Internal communication failure 78
GFCI.Errleakage current high by itself High leakage current 81
GridF.OutLim by itself Grid frequency out of range 80
GridV.OutLim by itself Grid voltage out of range 80
IntFanErr by itself Fan fault alarm 79
IsolationErrInsulation resistance low Low insulation resistance 81
PV ReversePV input reverse connection Reverse polarity 82
PVVoltOver DC overvoltage 82
TempOverOver-temperature protection fault by itself Inverter overtemperature 80
Fault0020Bus over volt Hardware fault after a manual reset DC bus overvoltage 84
Fault0060CPLD Fault fault after a manual reset 84
Fault0090Static leakage current high fault High leakage current 83
Fault0100Grid relay fault fault after a manual reset 83
Fault0110Bus imbalance fault Neutral point voltage imbalance 83
Fault0130Bus over total voltage fault after a manual reset DC bus overvoltage 83
Fault0150Open-loop self-check failure fault after a manual reset Self-test failure 84
Protect0020Grid relay error fault after a manual reset 80
Protect0030Inverter Over Current fault after a manual reset Inverter overcurrent 80
Protect0070Bus imbalance fault Neutral point voltage imbalance 80
Protect0100The sensor fault of leakage current fault after a manual reset 82
Protect0110BUS over voltage (firmware) fault after a manual reset DC bus overvoltage 82
Protect0150Mini MCU Fault fault after a manual reset Internal device fault 81
Protect0170DCI high fault High DC injection 81
Protect0180The sampling offset of DCI fault DC injection monitoring error 81
Protect0230Inverter open-loop self-test fault fault after a manual reset Self-test failure 82
WARN-30EepromErr warning stops Unauthorized network access attempt 79
Warn0040DC SPD fault warning Surge protector alarm 79
Warn0050TempSensorErr warning after a manual reset Abnormal temperature reading 79
Warn0100AC SPD fault warning Surge protector alarm 79

Solectria PVI 23/28/36TL

CodeShown asClassProductionClearsReportsPage
Arc Board ErrorInternal Arc board self-check error fault by itself Self-test failure 53
Arc Protect fault stops by itself Arc fault detected 55
EepromErrIncorrect memory reading warning by itself Internal memory error 53
ExtFanErr warning by itself Fan fault alarm 52
GFCI.ErrDC leakage current is above recommended value fault by itself High leakage current 54
GridF.OutLimGrid voltage frequency is abnormal fault by itself Grid frequency out of range 54
GridV.OutLimGrid voltage exceeds the specified range fault by itself Grid voltage out of range 53
IntFanErr warning by itself Fan fault alarm 52
IsolationErrDC insulation impedance to ground fault needs service Low insulation resistance 54
OverTemp fault by itself Inverter overtemperature 53
PV1 (2) ReverseDC inputs connected with incorrect polarities fault Reverse polarity 54
PV1 (2) VoltOverDC input voltage exceeds the specified value fault by itself DC overvoltage 54
SPICommErrInverter's internal communication failure warning by itself Internal communication failure 52
TempSensorErrAbnormal temperature reading warning after a manual reset Abnormal temperature reading 52
IntFault0010-150Internal non-critical fault within the inverter fault stops by itself Internal device fault 55
IntProtect0010-0260Internal problem within the inverter fault stops by itself Internal device fault 55

Solectria SGI 500/750XTM

CodeShown asClassProductionClearsReportsPage
AC Islanding informational stops Grid loss 115
Contactor Fail fault stops after a manual reset Switching device status fault 114
CT Failure fault after a manual reset 114
Current Limit informational reduced Inverter power derating 115
DC Cont. Err informational needs service Contactor fails to open 115
DC GND Fault fault needs service Ground fault alarm or trip 114
DC Overshoot informational after a manual reset DC bus overvoltage 115
DC Volt High informational DC overvoltage 115
DC Volt Low informational stops by itself Insufficient DC input power 115
Desat Error fault after a manual reset Internal device fault 114
Fac High informational stops by itself Grid overfrequency 115
Fac Low informational stops by itself Grid underfrequency 115
Fac Very Low informational stops by itself Grid underfrequency 115
Fan Life Reached informational needs service Fan service life reached 115
Filter Cont. Err warning unaffected after a manual reset Output filter malfunction 115
Flux Error after a manual reset Grid synchronization failure 115
Hw Interlock stops after a manual reset DC undervoltage 115
IGBT Overtemp fault after a manual reset Inverter overtemperature 114
Low DC Power informational stops by itself Insufficient DC input power 115
Master NTC Error needs service 115
MOV Fault warning unaffected needs service 114
MPP Tracking informational unaffected 115
Nameplate Limits informational reduced Flat capped output 116
NTC Failure fault after a manual reset 114
Open Phase fault Phase loss 114
Other PB Fault needs service 116
Outside MPPT informational 116
PAR Backup Err needs service Configuration error 116
PAR Config Err needs service Configuration error 116
Power Derated warning reduced needs service Inverter power derating 116
Power Disabled informational stops Remote shutdown 116
PS Fail needs service 116
PS Wake Fail stops after a manual reset 116
Pw Brd Mismatch needs service Configuration error 116
PWM Trip after a manual reset 116
RCM Fault fault needs service Ground fault alarm or trip 114
RCM Warn warning unaffected High leakage current 116
Remote Limiting informational reduced Remote power limit 116
Reverse Phase stops after a manual reset Incorrect phase sequence 116
Shunt Trip fault stops after a manual reset Remote shutdown 114
Slave NTC Error needs service 116
Slave Trip needs service 116
Soft Shutdown stops after a manual reset Remote shutdown 116
Temp 1 Limiting reduced Inverter overtemperature 116
Temp 2 Limiting reduced Inverter overtemperature 116
Temp 3 Limiting reduced Inverter overtemperature 116
Vac High stops by itself Grid overvoltage 117
Vac Low stops by itself Grid undervoltage 117
Vac Very High stops by itself Grid overvoltage 117
Vac Very Low stops by itself Grid undervoltage 117
Vsense Error fault needs service 114
Vsense Mismatch Software version mismatch 117
Wait for Grid stops Grid loss 117
Wait to Restart informational stops by itself 117
Temp 4 reduced 116

Yaskawa Solectria XGI 1500

CodeShown asClassProductionClearsReportsPage
CRIT-1Software Parameter Load Failure fault after a manual reset Parameter download failure 52
CRIT-2Internal Communication 1 Failure fault after a manual reset Internal communication failure 52
CRIT-3Internal Communication 2 Failure fault after a manual reset Internal communication failure 52
CRIT-4ARC Fault Detected fault after a manual reset Arc fault detected 52
CRIT-5AC Contactor Failure fault after a manual reset Switching device status fault 52
CRIT-6Critical Over Temperature fault Inverter overtemperature 53
CRIT-7Ground Fault, Excessive Leakage Current fault needs service Ground fault alarm or trip 53
CRIT-8Ground Fault, Isolation Resistance Low fault 53
CRIT-9Critical Internal Hardware Failure fault after a manual reset Internal device fault 53
CRIT-10Ground Fault Detection Self Check Failure fault 53
CRIT-11Operational Self Check Failure fault after a manual reset Self-test failure 53
CRIT-12Startup Self Check Failure fault after a manual reset Self-test failure 53
CRIT-32 fault 53
INFO-1Power Derating, Temperature informational reduced Inverter overtemperature 56
INFO-2Power Derating, Customer Command informational reduced Remote power limit 56
INFO-32 informational 56
WARN-1Internal Over Current/ Over Voltage warning stops after a manual reset Internal overcurrent or overvoltage 54
WARN-2Phase Lock Loop Failure warning stops after a manual reset Grid synchronization failure 54
WARN-3Islanding Detected warning stops by itself Islanding detected 54
WARN-4Open Phase Detected warning stops by itself Phase loss 54
WARN-5AC Low Frequency 1 Detected warning stops by itself Grid underfrequency 54
WARN-6AC Very Low Frequency 2 Detected warning stops by itself Grid underfrequency 54
WARN-7AC High Frequency 1 Detected warning stops by itself Grid overfrequency 54
WARN-8AC Very High Frequency 2 Detected warning stops by itself Grid overfrequency 55
WARN-9AC Low Voltage 1 Detected warning stops by itself Grid undervoltage 55
WARN-10AC Very Low Voltage 2 Detected warning stops by itself Grid undervoltage 55
WARN-11AC Extremely Low Voltage 3 Detected warning stops by itself Grid undervoltage 55
WARN-12AC High Voltage 1 Detected warning stops by itself Grid overvoltage 55
WARN-13AC Very High Voltage 2 Detected warning stops by itself Grid overvoltage 55
WARN-25Communication 1 Fault warning stops after a manual reset Internal device fault 55
WARN-26Communication 2 Fault warning stops after a manual reset Internal device fault 55
WARN-27Communication 3 Fault warning stops after a manual reset Internal device fault 56
WARN-28Network Fault warning stops Communication loss 56
WARN-29Software Update Fault warning stops after a manual reset Firmware update failure 56
WARN-30Unauthorized Network Access warning stops Unauthorized network access attempt 56
WARN-31Invalid Configuration Request warning stops Parameter change rejected, Configuration error 56
WARN-32 warning 56

Yaskawa Solectria XGI 1500-1MW

CodeShown asClassProductionClearsReportsPage
CRIT-1Software Parameter Load Failure fault after a manual reset Parameter download failure 64
CRIT-2Internal Communication 1 Failure fault after a manual reset Internal communication failure 64
CRIT-3Internal Communication 2 Failure fault after a manual reset Internal communication failure 64
CRIT-5AC Contactor Failure fault after a manual reset Switching device status fault 64
CRIT-6Critical Over Temperature fault Inverter overtemperature 64
CRIT-7Ground Fault fault needs service Ground fault alarm or trip 64
CRIT-9Critical Internal Hardware Failure fault after a manual reset Internal device fault 64
CRIT-11Operational Self Check Failure fault after a manual reset Self-test failure 64
CRIT-12Startup Self Check Failure fault after a manual reset Self-test failure 64
CRIT-32 fault 64
INFO-1Power Derating, Temperature informational reduced Inverter overtemperature 67
INFO-2Power Derating, Customer Command informational reduced Remote power limit 67
WARN-1Internal Over Current/ Over Voltage warning stops after a manual reset Internal overcurrent or overvoltage 65
WARN-2Phase Lock Loop Failure warning stops after a manual reset Grid synchronization failure 65
WARN-3Islanding Detected warning stops by itself Islanding detected 65
WARN-4Open Phase Detected warning stops by itself Phase loss 65
WARN-5AC Low Frequency 1 Detected warning stops by itself Grid underfrequency 65
WARN-6AC Very Low Frequency 2 Detected warning stops by itself Grid underfrequency 65
WARN-7AC High Frequency 1 Detected warning stops by itself Grid overfrequency 65
WARN-8AC Very High Frequency 2 Detected warning stops by itself Grid overfrequency 66
WARN-9AC Low Voltage 1 Detected warning stops by itself Grid undervoltage 66
WARN-10AC Very Low Voltage 2 Detected warning stops by itself Grid undervoltage 66
WARN-11AC Extremely Low Voltage 3 Detected warning stops by itself Grid undervoltage 66
WARN-12AC High Voltage 1 Detected warning stops by itself Grid overvoltage 66
WARN-13AC Very High Voltage 2 Detected warning stops by itself Grid overvoltage 66
WARN-25Communication 1 Fault warning stops after a manual reset Internal device fault 66
WARN-26Communication 2 Fault warning stops after a manual reset Internal device fault 66
WARN-27Communication 3 Fault warning stops after a manual reset Internal device fault 67
WARN-28Network Fault warning stops Communication loss 67
WARN-29Software Update Fault warning stops after a manual reset Firmware update failure 67
WARN-30Unauthorized Network Access warning stops Unauthorized network access attempt 67
WARN-31Invalid Configuration Request warning stops Parameter change rejected 67
WARN-32 warning 67

Yaskawa Solectria XGI 1500-DCG

CodeShown asClassProductionClearsReportsPage
CRIT-1Software Parameter Load Failure fault after a manual reset Parameter download failure 54
CRIT-2Internal Communication 1 Failure fault after a manual reset Internal communication failure 54
CRIT-3Internal Communication 2 Failure fault after a manual reset Internal communication failure 54
CRIT-5AC Contactor Failure fault after a manual reset Switching device status fault 54
CRIT-6Critical Over Temperature fault Inverter overtemperature 54
CRIT-7Ground Fault fault needs service Ground fault alarm or trip 55
CRIT-9Critical Internal Hardware Failure fault after a manual reset Internal device fault 55
CRIT-11Operational Self Check Failure fault after a manual reset Self-test failure 55
CRIT-12Startup Self Check Failure fault after a manual reset Self-test failure 55
CRIT-32Reserved fault 55
INFO-1Power Derating, Temperature informational reduced Inverter overtemperature 58
INFO-2Power Derating, Customer Command informational reduced Remote power limit 58
WARN-1Internal Over Current/ Over Voltage warning stops after a manual reset Internal overcurrent or overvoltage 56
WARN-2Phase Lock Loop Failure warning stops after a manual reset Grid synchronization failure 56
WARN-3Islanding Detected warning stops by itself Islanding detected 56
WARN-4Open Phase Detected warning stops by itself Phase loss 56
WARN-5AC Low Frequency 1 Detected warning stops by itself Grid underfrequency 56
WARN-6AC Very Low Frequency 2 Detected warning stops by itself Grid underfrequency 56
WARN-7AC High Frequency 1 Detected warning stops by itself Grid overfrequency 56
WARN-8AC Very High Frequency 2 Detected warning stops by itself Grid overfrequency 57
WARN-9AC Low Voltage 1 Detected warning stops by itself Grid undervoltage 57
WARN-10AC Very Low Voltage 2 Detected warning stops by itself Grid undervoltage 57
WARN-11AC Extremely Low Voltage 3 Detected warning stops by itself Grid undervoltage 57
WARN-12AC High Voltage 1 Detected warning stops by itself Grid overvoltage 57
WARN-13AC Very High Voltage 2 Detected warning stops by itself Grid overvoltage 57
WARN-25Communication 1 Fault warning stops after a manual reset Internal device fault 57
WARN-26Communication 2 Fault warning stops after a manual reset Internal device fault 57
WARN-27Communication 3 Fault warning stops after a manual reset Internal device fault 58
WARN-28Network Fault warning stops Communication loss 58
WARN-29Software Update Fault warning stops after a manual reset Firmware update failure 58
WARN-30Unauthorized Network Access warning stops Unauthorized network access attempt 58
WARN-31Invalid Configuration Request warning stops Parameter change rejected 58
WARN-32 warning 58