c1 drafted · lead PVI 20-25TL-480-R IOM DOCR-071030-A
- PVI 20-25TL-480-R IOM DOCR-071030-A
tbl=35.r3h=0ea62c5cf5f4
Fault codes › Yaskawa Solectria › Solectria PVI 20/25TL-480-R
Reports inverter overcurrent; do: inverter restart, inverter replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
tbl=35.r3 h=0ea62c5cf5f4The manufacturer's own cause and corrective text is not reproduced here.
defined_inc1 drafted · lead PVI 20-25TL-480-R IOM DOCR-071030-A
tbl=35.r3 h=0ea62c5cf5f4has_event_classc2 drafted · lead Fault (device stops or needs intervention)
from the code prefix
tbl=35.r3 h=0ea62c5cf5f4reportsc3 drafted · lead Inverter overcurrent
tbl=35.r3 h=0ea62c5cf5f4mitigated_byc4 drafted · lead Inverter restart
tbl=35.r3 h=0ea62c5cf5f4c6 drafted · lead Inverter replacement
Only if the restart does not clear it
tbl=35.r3 h=0ea62c5cf5f4has_recoveryc5 drafted · lead Manual reset (operator restarts or acknowledges)
Power-cycle AC and DC first; replace the inverter if the fault persists
tbl=35.r3 h=0ea62c5cf5f4applies_toc7 drafted · lead Solectria PVI 20/25TL-480-R