Solar Lattice

EventConcept

No production effect

ID
ec:no-production-effect
IRI
https://solarlattice.org/kb/ec/no-production-effect
Status
active
Also known as
continues to feed in, no effect on output, production unaffected
Axis
production_effect

Production is unaffected: the row says the device continues to feed in, or the message is a status that changes nothing about output.

Reading rule: only an explicit statement ("the inverter continues to feed in", "no effect on operation") or a plainly informational message reads as this concept. Silence about output yields no claim, never this one.

Referenced by

Every fault code that carries this concept, by make: the cross-vendor answer to which codes trip, derate or clear by themselves.

ABB / FIMER

CodeFamilyShown asClaim
ABB / FIMER PVS-166-175-TL W022FIMER PVS-166/175-TL-USQ-mode Changehas_production_effect c4 drafted · lead
ABB / FIMER PVS-166-175-TL W023FIMER PVS-166/175-TL-USDate/time mod.has_production_effect c4 drafted · lead
ABB / FIMER PVS-166-175-TL W024FIMER PVS-166/175-TL-USEnergy data rsthas_production_effect c4 drafted · lead
ABB / FIMER PVS-166-175-TL W025FIMER PVS-166/175-TL-USP-reduction Endhas_production_effect c4 drafted · lead
ABB / FIMER PVS-166-175-TL W026FIMER PVS-166/175-TL-USAFDD user resethas_production_effect c4 drafted · lead
ABB / FIMER PVS-166-175-TL W049FIMER PVS-166/175-TL-USGlobal-Settings Eventhas_production_effect c4 drafted · lead
ABB / FIMER PVS-60-TL W022FIMER PVS-60-TL-USReactive power mode changedhas_production_effect c4 verified · fact
ABB / FIMER PVS-60-TL W023FIMER PVS-60-TL-USdate/time changedhas_production_effect c4 drafted · lead
ABB / FIMER PVS-60-TL W024FIMER PVS-60-TL-USEnergy data resethas_production_effect c4 verified · fact
ABB / FIMER PVS-60-TL W025FIMER PVS-60-TL-USP-reductionEndhas_production_effect c4 verified · fact
ABB / FIMER PVS-60-TL W026FIMER PVS-60-TL-USAFDD user resethas_production_effect c4 drafted · lead
ABB / FIMER PVS-60-TL W027FIMER PVS-60-TL-USLatch-Manual resethas_production_effect c4 drafted · lead
ABB / FIMER PVS-60-TL W049FIMER PVS-60-TL-USGlobal-Settings Eventhas_production_effect c4 drafted · lead
ABB / FIMER TRIO-20.0-27.6-TL W022TRIO-20.0/27.6-TL-OUTD(-US)has_production_effect c4 drafted · lead
ABB / FIMER TRIO-20.0-27.6-TL W023TRIO-20.0/27.6-TL-OUTD(-US)date/time changedhas_production_effect c4 drafted · lead
ABB / FIMER TRIO-20.0-27.6-TL W024TRIO-20.0/27.6-TL-OUTD(-US)has_production_effect c4 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W022UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USReactive power mode changedhas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W023UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USdate/time changedhas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W024UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USEnergy data resethas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W026UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USAFDD user resethas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W027UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USLatch-Manual resethas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-3.3-5.0-PLUS W049UNO-DM-3.3/3.8/4.6/5.0-TL-PLUS-USGlobal-Settings Eventhas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-6.0-PLUS W022UNO-DM-6.0-TL-PLUS-USReactive power mode changedhas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-6.0-PLUS W023UNO-DM-6.0-TL-PLUS-USdate/time changedhas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-6.0-PLUS W024UNO-DM-6.0-TL-PLUS-USEnergy data resethas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-6.0-PLUS W026UNO-DM-6.0-TL-PLUS-USAFDD user resethas_production_effect c5 verified · fact
ABB / FIMER UNO-DM-6.0-PLUS W027UNO-DM-6.0-TL-PLUS-USLatch-Manual resethas_production_effect c5 drafted · lead
ABB / FIMER UNO-DM-6.0-PLUS W049UNO-DM-6.0-TL-PLUS-USGlobal-Settings Eventhas_production_effect c5 drafted · lead

CPS

CodeFamilyShown asClaim
CPS SCA25KTL-480 Warn0100CPS SCA25KTL-DO-R/US-480AC SPD faulthas_production_effect c5 drafted · lead
CPS SCA50-100K-T Warn0100CPS SCA100K-T-US-480 / SCA50K-T-US-208AC lightning protector Abnhas_production_effect c5 drafted · lead
CPS SCH100-125KTL Warn0100CPS SCH100/125KTL-DO/US-600AC SPD faulthas_production_effect c5 drafted · lead
CPS SCH125KTL-AIO Warn0100CPS SCH125KTL-AIO/US-600AC SPD faulthas_production_effect c5 drafted · lead
CPS SCH275KTL Warn0100CPS SCH275KTL-DO/US-800AC SPD faulthas_production_effect c5 drafted · lead
CPS SCH350KTL Warn0100CPS SCH350KTL-DO/US-800AC SPD faulthas_production_effect c5 drafted · lead

Fronius

CodeFamilyShown asClaim
Fronius Galvo 502Fronius Galvo 208-240 (1.5-1 to 3.1-1)Insulation error on the solar moduleshas_production_effect c6 drafted · lead
Fronius Galvo 566Fronius Galvo 208-240 (1.5-1 to 3.1-1)has_production_effect c5 drafted · lead
Fronius Galvo 758Fronius Galvo 208-240 (1.5-1 to 3.1-1)has_production_effect c5 verified · fact
Fronius Primo 502Fronius Primo 208-240 (3.8-1 to 15.0-1)Insulation fault on solar moduleshas_production_effect c6 drafted · lead
Fronius Primo 515Fronius Primo 208-240 (3.8-1 to 15.0-1)Communication with filter not possiblehas_production_effect c5 drafted · lead
Fronius Primo 516Fronius Primo 208-240 (3.8-1 to 15.0-1)Communication with memory unit not possiblehas_production_effect c5 verified · fact
Fronius Primo 522Fronius Primo 208-240 (3.8-1 to 15.0-1)DC low String 1has_production_effect c4 drafted · lead
Fronius Primo 523Fronius Primo 208-240 (3.8-1 to 15.0-1)DC low String 2has_production_effect c3 drafted · lead
Fronius Primo 566Fronius Primo 208-240 (3.8-1 to 15.0-1)has_production_effect c5 drafted · lead
Fronius Primo 758Fronius Primo 208-240 (3.8-1 to 15.0-1)has_production_effect c5 drafted · lead
Fronius Symo 502Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Insulation fault on solar moduleshas_production_effect c6 drafted · lead
Fronius Symo 515Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Communication with filter not possiblehas_production_effect c5 drafted · lead
Fronius Symo 516Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Communication with memory unit not possiblehas_production_effect c5 drafted · lead
Fronius Symo 518Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Internal DSP malfunctionhas_production_effect c5 drafted · lead
Fronius Symo 519Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Communication with memory unit not possiblehas_production_effect c5 drafted · lead
Fronius Symo 522Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)DC low String 1has_production_effect c4 drafted · lead
Fronius Symo 523Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)DC low String 2has_production_effect c3 drafted · lead
Fronius Symo 566Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)has_production_effect c5 drafted · lead
Fronius Symo 573Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)Undertemperature warninghas_production_effect c4 drafted · lead
Fronius Symo 753Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)has_production_effect c5 drafted · lead
Fronius Symo 758Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)has_production_effect c5 drafted · lead

Huawei

CodeFamilyShown asClaim
Huawei SUN2000-100KTL-USH0 2065Huawei SUN2000-100KTL-USH0Upgrade Failedhas_production_effect c5 drafted · lead
Huawei SUN2000-100KTL-USH0 61440Huawei SUN2000-100KTL-USH0Faulty Monitoring Unithas_production_effect c7 verified · fact
Huawei SUN2000-25-30KTL-US 504Huawei SUN2000-25KTL-US / SUN2000-30KTL-USVersion Mismatchhas_production_effect c5 verified · fact
Huawei SUN2000-25-30KTL-US 61440Huawei SUN2000-25KTL-US / SUN2000-30KTL-USFlash Faulthas_production_effect c7 verified · fact
Huawei SUN2000-45KTL-US-HV-D0 504Huawei SUN2000-45KTL-US-HV-D0Software Version Unmatchhas_production_effect c5 drafted · lead
Huawei SUN2000-45KTL-US-HV-D0 61440Huawei SUN2000-45KTL-US-HV-D0Flash Faulthas_production_effect c7 drafted · lead

KACO new energy

CodeFamilyShown asClaim
KACO new energy blueplanet TL3 107KACO blueplanet 87.0-165 TL3Check surge protection devicehas_production_effect c8 drafted · lead
KACO new energy blueplanet TL3 187KACO blueplanet 87.0-165 TL3Fault in fan 4has_production_effect c7 drafted · lead
KACO new energy blueplanet TL3 4KACO blueplanet 87.0-165 TL3Feed in at max. MPPhas_production_effect c3 verified · fact
KACO new energy blueplanet TL3 71KACO blueplanet 87.0-165 TL3Fault in fan 2has_production_effect c5 verified · fact
KACO new energy blueplanet TL3 72KACO blueplanet 87.0-165 TL3Fault in fan 3has_production_effect c5 drafted · lead

SMA

CodeFamilyShown asClaim
SMA SB-US-40 10255Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)[Interface]: Network load OKhas_production_effect c3 drafted · lead
SMA SB-US-40 10285Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)WLAN connection establishedhas_production_effect c3 drafted · lead
SMA SB-US-40 10339Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)Webconnect enabledhas_production_effect c3 drafted · lead
SMA SB-US-40 6701-6702Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)has_production_effect c6 drafted · lead
SMA SB-US-40 7106Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)has_production_effect c7 drafted · lead
SMA SB-US-40 7110Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)has_production_effect c5 drafted · lead
SMA SB-US-41 10255Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)[Interface]: Network load OKhas_production_effect c3 drafted · lead
SMA SB-US-41 10285Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)WiFi connection establishedhas_production_effect c3 drafted · lead
SMA SB-US-41 10339Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)Webconnect enabledhas_production_effect c3 drafted · lead
SMA SB-US-41 6701Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)Communication impairedhas_production_effect c6 drafted · lead
SMA SB-US-41 6702Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)Communication impairedhas_production_effect c6 drafted · lead
SMA SB-US-41 7106Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)has_production_effect c7 drafted · lead
SMA SB-US-41 7110Sunny Boy 3.0-7.7-US (SBx.x-1SP-US-41)No update file foundhas_production_effect c5 drafted · lead
SMA SBSE-US-50 8710Sunny Boy Smart Energy 3.8-11.5-US (SBSEx.x-US-50)has_production_effect c5 drafted · lead
SMA PEAK3-US 6701Sunny Highpower PEAK3 (SHP 125-172-US)Communication impairedhas_production_effect c6 drafted · lead
SMA PEAK3-US 7102Sunny Highpower PEAK3 (SHP 125-172-US)Parameter file not found or defectivehas_production_effect c5 drafted · lead
SMA PEAK3-US 8710Sunny Highpower PEAK3 (SHP 125-172-US)has_production_effect c5 drafted · lead
SMA CORE1-US 10255Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c3 drafted · lead
SMA CORE1-US 10285Sunny Tripower CORE1-US (STP 33/50/62-US-41)Wi-Fi connection establishedhas_production_effect c5 drafted · lead
SMA CORE1-US 10339Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c3 drafted · lead
SMA CORE1-US 6701Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c8 drafted · lead
SMA CORE1-US 6702Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c8 verified · fact
SMA CORE1-US 7102Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c7 drafted · lead
SMA CORE1-US 7105Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c8 verified · fact
SMA CORE1-US 7106Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c9 drafted · lead
SMA CORE1-US 7110Sunny Tripower CORE1-US (STP 33/50/62-US-41)has_production_effect c7 verified · fact
SMA STP-TL-US 6701-6702Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c6 drafted · lead
SMA STP-TL-US 7102Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c5 drafted · lead
SMA STP-TL-US 7105Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c6 drafted · lead
SMA STP-TL-US 7106Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c7 drafted · lead
SMA STP-TL-US 7110Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c5 drafted · lead
SMA STP-TL-US 7201-7202Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c4 drafted · lead
SMA STP-TL-US 8710Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)has_production_effect c5 drafted · lead
SMA STP-X-US 8710Sunny Tripower X 13-30-US (STP xx-US-50)has_production_effect c5 drafted · lead
SMA SC-CP-XT 8701Sunny Central 500CP XT-1000CP XThas_production_effect c4 drafted · lead
SMA SI-US E104Sunny Island 4548-US / 6048-USOperating on the generator (at external input)has_production_effect c3 drafted · lead
SMA SI-US E105Sunny Island 4548-US / 6048-USOperation on utility grid (at external input)has_production_effect c3 verified · fact
SMA SI-US E106Sunny Island 4548-US / 6048-USFeeding-in grid operation (at external input)has_production_effect c3 drafted · lead

Schneider Electric

CodeFamilyShown asClaim
Schneider Electric CL125 074Schneider Electric Conext CL125Communication eventhas_production_effect c5 verified · fact

Solis

CodeFamilyShown asClaim
Solis S6-EH2P GridToLoadSolis S6-EH2P(9.6-16)K-SV-YD-L-USGrid to loadhas_production_effect c3 drafted · lead
Solis S6-EH3P30-60K GridToLoadSolis S6-EH3P(30-60)K-NV-YD-H-USGrid to loadhas_production_effect c4 drafted · lead
Solis S6-EH3P75-150K GridToLoadSolis S6-EH3P(75-150)K10-NV-YD-H-USGrid to loadhas_production_effect c3 drafted · lead

Sungrow

CodeFamilyShown asClaim
Sungrow SG-CX-US 087Sungrow SG36/60CX-USElectric arc detection module abnormalhas_production_effect c6 verified · fact
Sungrow SG200HX 216-218Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 220-233Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 332-363Sungrow SG200HX-USBoost Capacitor Overvoltage Alarmhas_production_effect c4 drafted · lead
Sungrow SG200HX 432-434Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 500-513Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 515-518Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 59Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 635-638Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 70-74Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 76-83Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 89Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 900Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 901Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 910Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 911Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG200HX 996Sungrow SG200HX-USSystem Alarmhas_production_effect c3 verified · fact
Sungrow SG250HX 216-218Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 220-232Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 332-363Sungrow SG250HXBoost Capacitor Overvoltage Alarmhas_production_effect c4 drafted · lead
Sungrow SG250HX 432-434Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 500-513Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 515-518Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 59Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 635-638Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 70-74Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 76Sungrow SG250HXSystem Alarmhas_production_effect c4 drafted · lead
Sungrow SG250HX 77-81Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 82Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 83Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 87Sungrow SG250HXSystem Faulthas_production_effect c4 drafted · lead
Sungrow SG250HX 89Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 900Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 901Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 910Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 911Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG250HX 996Sungrow SG250HXSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 216-218Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 220-233Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 332-363Sungrow SG350HX-USBoost Capacitor Overvoltage Alarmhas_production_effect c4 drafted · lead
Sungrow SG350HX 432-434Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 500-513Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 515-518Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 59Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 635-638Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 70-74Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 76-83Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 89Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 900Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 901Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 910Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 911Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead
Sungrow SG350HX 996Sungrow SG350HX-USSystem Alarmhas_production_effect c3 drafted · lead

Yaskawa Solectria

CodeFamilyShown asClaim
Yaskawa Solectria SGI-XTM Filter Cont. ErrSolectria SGI 500/750XTMhas_production_effect c5 drafted · lead
Yaskawa Solectria SGI-XTM MOV FaultSolectria SGI 500/750XTMhas_production_effect c5 drafted · lead
Yaskawa Solectria SGI-XTM MPP TrackingSolectria SGI 500/750XTMhas_production_effect c3 drafted · lead
Yaskawa Solectria SGI-XTM RCM WarnSolectria SGI 500/750XTMhas_production_effect c4 drafted · lead

Data