Solar Lattice

Fault codes › Yaskawa Solectria › Yaskawa Solectria XGI 1500-DCG

Yaskawa Solectria XGI-1500-DCG WARN-29

Code
WARN-29
Shown as
Software Update Fault
Vendor severity
Warning
Page
58
ID
fc:yaskawa-solectria-xgi-1500-dcg-warn29
IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-xgi-1500-dcg-warn29
Status
active
Also known as
WARN-29, warn29, Yaskawa Solectria WARN-29, Software Update Fault
Category
Inverters
Class warning drafted · lead
Production stops drafted · lead
Clears after a manual reset drafted · lead

Decoded

Reports firmware update failure; look at communication processor; do: inverter restart.

What can be behind Firmware update failure

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL W047, ABB / FIMER PVS-60-TL W047, ABB / FIMER UNO-DM-3.3-5.0-PLUS W047, ABB / FIMER UNO-DM-6.0-PLUS W047
Fronius
Fronius Galvo 734, Fronius Galvo 735, Fronius Galvo 743, Fronius Galvo 745, Fronius Primo 734, Fronius Primo 735, Fronius Primo 743, Fronius Primo 745, Fronius Symo 734, Fronius Symo 735, Fronius Symo 743, Fronius Symo 745, Fronius Symo 746
Huawei
Huawei SUN2000-100KTL-USH0 2065, Huawei SUN2000-25-30KTL-US 505, Huawei SUN2000-45KTL-US-HV-D0 505
SMA
SMA SB-US-40 7106, SMA SB-US-40 7110, SMA SB-US-40 7303, SMA SB-US-40 7324, SMA SB-US-40 7333, SMA SB-US-40 7340, SMA SB-US-40 7352, SMA SB-US-40 7356, SMA SB-US-41 7106, SMA SB-US-41 7110, SMA SB-US-41 7303, SMA SB-US-41 7324, SMA SB-US-41 7333, SMA SB-US-41 7340, SMA SB-US-41 7352, SMA SB-US-41 7356, SMA PEAK3-US 7303, SMA PEAK3-US 7324, SMA PEAK3-US 7330, SMA PEAK3-US 7333, SMA CORE1-US 7106, SMA CORE1-US 7110, SMA CORE1-US 7303, SMA CORE1-US 7330, SMA CORE1-US 7333, SMA CORE1-US 7342, SMA CORE1-US 7352, SMA CORE1-US 7356, SMA STP-TL-US 7106, SMA STP-TL-US 7110, SMA STP-TL-US 7303, SMA STP-TL-US 7305, SMA STP-TL-US 7311, SMA STP-TL-US 7316, SMA STP-TL-US 7324, SMA STP-TL-US 7326
Yaskawa Solectria
Yaskawa Solectria XGI-1500-1MW WARN-29, Yaskawa Solectria XGI-1500 WARN-29

Same code in other families

Claims

defined_in

c1 drafted · lead XGI 1500 250 DCG IOM DOCR-071081-DD

has_event_class

c2 drafted · lead Warning (device continues, a condition is flagged)

from the table header

reports

c3 drafted · lead Firmware update failure

affects

c4 drafted · lead Communication processor

mitigated_by

c5 drafted · lead Inverter restart

has_production_effect

c6 drafted · lead Trip (production stops)

has_recovery

c7 drafted · lead Manual reset (operator restarts or acknowledges)

Power cycle first; contact service if the error persists.

review note: support check: partial - A power cycle and then contacting support matches a manual reset, but section 9.1.2 also says warnings can self-recover, so…

applies_to

c8 drafted · lead Solectria XGI 1500-DCG

Data