c1 drafted · lead Yaskawa Solectria Solar
- XGI 1500 250 DCG IOM DOCR-071081-DD
sec=h1h=8e118d3d2649 - XGI 1500 DCG Interconnection Guidelines
sec=h1h=645c74748b80 - XGI 1500 250 DCG IOM DOCR-071081-DD
sec=h164h=ead7ec075abd
The Solectria XGI 1500-DCG is a Yaskawa Solectria Solar family of inverters. It has four models: XGI 1500-250/250-600-DCG, 225-600-DCG, 200/200-480-DCG and 175-480-DCG. These inverters use a functionally grounded DC negative, which prevents potential induced degradation in PV modules that are prone to it. Yaskawa Solectria applications engineering must review every project's single-line diagram and transformer configuration. A separate transformer specification guide covers compatibility. Every model accepts a maximum DC input of 1500 V. The full-power input range is 860 to 1250 V on the 250 and 225 models and 750 to 1250 V on the 200 and 175 models. The inverters comply with UL 1741 Edition 3, IEEE 1547.1-2020 and IEEE 1547-2018. That covers Normal Operating Performance Category B and Abnormal Operating Performance Category III. You can reach the inverter over Wi-Fi from a smart device or over Ethernet from a PC. It has two interchangeable Ethernet ports in the wire box, and weather stations and data acquisition systems connect by Ethernet. The inverters work with SolrenView monitoring without extra hardware, and third-party monitoring platforms are also supported. The 250 kW DCG model is the inverter used in XGI 1500 PowerRack assemblies, which hold from two to eight units.
<!-- review notes
manufactured_byc1 drafted · lead Yaskawa Solectria Solar
sec=h1 h=8e118d3d2649sec=h1 h=645c74748b80sec=h164 h=ead7ec075abdmax_input_voltagec2 drafted · lead nominal 1500 V
Conditions: Maximum DC input voltage, all four DCG models
tbl=23.r1 h=fdd9fe2523fdmppt_voltage_rangeConditions: Full-power input voltage range, XGI 1500-250/250-600-DCG and XGI 1500-225-600-DCG
tbl=23.r2 h=3d32069aa45bverified by: review-workflowverified on: 2026-10-24
Conditions: Full-power input voltage range, XGI 1500-200/200-480-DCG and XGI 1500-175-480-DCG
tbl=23.r2 h=3d32069aa45bcompatible_withc5 drafted · lead Functionally grounded PV array
Uses a functionally grounded DC negative, which prevents PID in susceptible modules
sec=h1 h=8e118d3d2649c11 drafted · lead Solectria XGI 1500 PowerRack proposed
Conditions: XGI 1500-250/250-600-DCG model
PowerRack models PRU-2 through PRU-8 hold two to eight XGI 1500-250/250-600-DCG inverters
tbl=1.r3 h=1cb5deec38catbl=2.r3 h=fbf95c7f6781certified_toc6 drafted · lead UL 1741 proposed
UL 1741 Edition 3 (09/28/2021)
sec=h148 h=3cd140854ee5review note: support check: partial - The passage says the inverters comply with UL 1741 Edition 3, but it says nothing about certification, and it names only the 250 series.
c7 drafted · lead IEEE 1547-2018 proposed
sec=h148 h=3cd140854ee5review note: support check: partial - The passage says they comply with IEEE 1547-2018, not that they are certified, and it names only the 250 series.
c8 drafted · lead IEEE 1547.1-2020 proposed
sec=h148 h=3cd140854ee5review note: support check: partial - The passage says they comply with IEEE 1547.1-2020, not that they are certified, and it names only the 250 series.
uses_protocolAccess from a smart device such as a laptop, tablet or smartphone
sec=h76 h=3ce8feffcde0sec=2.1.3 h=866841f76f1fTwo interchangeable Ethernet ports in the wire box; used for PC access, weather station and DAS add-ons
sec=h76 h=3ce8feffcde0sec=2.1.3 h=866841f76f1fsec=h97 h=a8ae78dd57b9applies_to c7applies_to c7applies_to c7applies_to c7applies_to c7applies_to c3applies_to c8applies_to c8applies_to c7applies_to c8applies_to c8applies_to c7applies_to c7applies_to c7applies_to c7applies_to c7applies_to c8applies_to c7applies_to c8applies_to c8applies_to c8applies_to c8applies_to c8applies_to c9applies_to c5applies_to c6applies_to c3applies_to c9applies_to c7applies_to c7applies_to c7applies_to c7applies_to c7