Ethernet
Ethernet is a network technology that covers the physical and data link layers, as defined by IEEE 802.2 and IEEE 802.3. Canadian Solar CSI-125KTL-GS-E and CSI-125K-T600GL02-U inverters list Ethernet among their communication connections, alongside RS485. FIMER PVS-166/175-TL-US inverters can receive firmware updates, locally or remotely, and parameter upgrades over Ethernet or WLAN, with parameter upgrades following the SunSpec Modbus protocol. Inverters can be wired as a daisy chain or in a star around an Ethernet switch. A ring is also possible: FIMER recommends connecting the first and last inverters to the switch so the chain stays connected if one link fails, and SMA allows a ring only when spanning tree is used. The LAN port is usually set to DHCP, where the router assigns an address automatically, or to Static, where you enter a fixed IP address and the related network fields by hand. If a SolarEdge inverter shows the message to configure static IP or set DHCP, check the IP settings on both the router and the inverter and consult the site's network IT staff.
<!-- review notes
- sentence 4: support check: partial - The passages support daisy chain, star, the FIMER ring recommendation, and a ring only with spanning tree, but they don't attribute the spanning-tree condition to SMA.
- sentence 5: support check: partial - DHCP and Static are supported with the router assigning the address and manual entry, but the passages don't say these are the 'usual' settings, and they mention DHCP as the default and the mandatory fields except the secondary DNS server, not a list of 'related network fields'. -->
Referenced by
- Daisy-chain and star topology
related_toc1 - DHCP and static IP addressing
related_toc2 - Time-of-use optimization
requiresc2 - FIMER PVS-166/175-TL-US string inverter
uses_protocolc8 - Accuenergy Acuvim II power meter
uses_protocolc6 - Accuenergy AXM expansion modules (AXM-WEB2 / WEB PUSH)
uses_protocolc15 - Advantech ADAM-6000 Ethernet I/O modules
uses_protocolc4 - Advantech EKI-1200 Modbus gateways
uses_protocolc8 - AcquiSuite A8810 data acquisition server
requiresc12 - AlsoEnergy PLCS power limiting control system
uses_protocolc5 - AlsoEnergy PowerManager 2200
uses_protocolc1 - CSI-125K-T600GL02-U
uses_protocolc15 - CSI-125KTL-GS-E
uses_protocolc4 - CSI-75/80/90/100K-T480GL02-U
uses_protocolc7 - CPS FlexOM Gateway
uses_protocolc7 - CPS SCH275KTL-DO/US-800
uses_protocolc16 - Enphase IQ Gateway
uses_protocolc13 - Fronius Datamanager
uses_protocolc9 - SMA Hybrid Controller
uses_protocolc8 - SMA Inverter Manager
uses_protocolc10 - SMA Speedwire/Webconnect data module
uses_protocolc5 - Sunny Tripower CORE2
uses_protocolc3 - Sunny Tripower X (international)
uses_protocolc1 - Sunny WebBox
uses_protocolc5 - Solis DLS data logging stick
uses_protocolc4 - Solectria PVI 20/25TL-480-R
uses_protocolc6 - Solectria PVI 50-60TL
uses_protocolc4 - Solectria XGI 1500
uses_protocolc3 - Solectria XGI 1500-1MW
uses_protocolc16 - Solectria XGI 1500-DCG
uses_protocolc10 - Commissioning laptop
uses_protocolc1 - SEL AcSELerator QuickSet
uses_protocolc2 - Stem Athena
uses_protocolc2 - SolrenView
uses_protocolc3