Solar Lattice

Product

Solectria XGI 1500

ID
prod:yaskawa-solectria-xgi-1500
IRI
https://solarlattice.org/kb/prod/yaskawa-solectria-xgi-1500
Status
active
Also known as
XGI 1500, XGI 1500c, SGI 1500, Solectria XGI
Category
Inverters
Make
yaskawa-solectria
Product level
family

The Solectria XGI 1500 is a family of 1500 V three-phase inverters made by Yaskawa Solectria Solar. It includes the 125 to 250 kW models, the DCG variants and the XGI 1500-1MW utility-scale modular central series. In PowerRack configurations, each XGI 1500-250 inverter accepts up to 1500 Vdc. It tracks at full power from 860 to 1250 Vdc and feeds 600 Vac three-phase at 60 Hz. A PowerRack combines two to eight XGI 1500 inverters, for totals between 0.5 MW and 2 MW. It can also use the 600 Vac or 480 Vac models. You can reach the inverters over WiFi from a smart device or over Ethernet from a PC. They work with SolrenView monitoring without extra hardware, and a Modbus manual covers the smart grid features. The DCG models functionally ground the DC negative, which prevents PID in modules that are susceptible to it. Yaskawa's Applications Engineering team must review each project's single-line diagram and transformer configuration. The 1MW models are listed to UL 1741, IEEE 1547, UL 1998 and CSA C22.2 No. 107.1, with TÜV Rheinland as the testing agency. They support manual firmware updates through the Remote Access Portal. The CR1500 remote combiners are designed to pair with the XGI 1500-1MW series.

<!-- review notes

Claims

manufactured_by

c1 verified · fact Yaskawa Solectria Solar

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Passages show Yaskawa Solectria Solar offers/documents XGI 1500 inverters, but never explicitly state it makes them (title only implies).

uses_protocol

c2 drafted · lead Wi-Fi

Communication platform reachable over WiFi from a smart device.

c3 drafted · lead Ethernet

Accessible over Ethernet from a PC; the 1MW series has two interchangeable Ethernet ports.

c4 drafted · lead Modbus

A Smart Grid Feature and Modbus Manual covers XGI 1500 models from 125/125 to 250/250.

review note: support check: partial - A Modbus manual exists for those models, but the passage only lists models and doesn't explicitly say the inverter uses Modbus protocol.

implements

c5 drafted · lead Remote firmware update

Scope: products Solectria XGI 1500-1MW

Manual firmware updates are supported through the Remote Access Portal.

certified_to

c6 drafted · lead UL 1741 proposed

Scope: products Solectria XGI 1500-1MW

Listed as UL 1741 2021 for all XGI 1500-1MW models.

c7 drafted · lead IEEE 1547 proposed

Scope: products Solectria XGI 1500-1MW

c8 drafted · lead UL 1998 proposed

Scope: products Solectria XGI 1500-1MW

c9 drafted · lead CSA C22.2 No. 107.1 proposed

Scope: products Solectria XGI 1500-1MW

Listed as CSA C22.2 No. 107.1-16; testing agency TÜV Rheinland.

review note: support check: partial - CSA C22.2 No. 107.1-16 is listed, but TÜV Rheinland as testing agency is not in the cited passage (u2).; review: partial - CSA C22.2 No. 107.1-16 is listed for every XGI 1500 model, but the note's claim that TÜV Rheinland is the testing agency does not appear in the cited row.

compatible_with

c10 drafted · lead Functionally grounded PV array

Scope: products Solectria XGI 1500-DCG

DCG models use a functionally grounded DC negative, which prevents PID in susceptible modules; Applications Engineering must review each project's single-line diagram and transformer configuration.

c11 drafted · lead Solectria CR1500 PV combiner proposed

Scope: products Solectria XGI 1500-1MW

CR1500-xxP-yyS-400 and CR1500-xxP-yyF-400S remote combiners are designed for the XGI 1500-1MW series.

c12 drafted · lead Solectria XGI 1500 PowerRack proposed

PowerRacks combine two to eight XGI 1500 inverters.

max_input_voltage

c13 verified · fact nominal 1500 V

Conditions: Absolute maximum DC input voltage per XGI 1500-250 inverter in PowerRack configurations

verified by: review-workflowverified on: 2026-10-24

mppt_voltage_range

c14 drafted · lead 860–1250 V

Conditions: Full-power MPPT voltage range per XGI 1500-250 inverter in PowerRack configurations

c15 drafted · lead 860–1450 V

Conditions: MPPT operating voltage range per XGI 1500-250 inverter in PowerRack PRU-5 to PRU-8 configurations

max_input_current

c16 drafted · lead nominal 296.7 A

Conditions: Maximum operating PV current per XGI 1500-250 inverter in PowerRack configurations

review note: possible conflict with c17 (same source; check the conditions)

c17 drafted · lead nominal 800 A

Conditions: Maximum rated PV short-circuit current (sum of Isc x 1.25) per XGI 1500-250 inverter in PowerRack configurations

review note: possible conflict with c16 (same source; check the conditions)

nominal_voltage

c18 drafted · lead nominal 600 V

Conditions: Nominal three-phase AC output voltage, range -12% to +10%, XGI 1500-250 PowerRack configurations

frequency

c19 verified · fact nominal 60 HZ

Conditions: Nominal operating AC frequency, XGI 1500-250 PowerRack configurations

verified by: review-workflowverified on: 2026-10-24

rated_power

c20 verified · fact nominal 225 KiloW

Conditions: XGI 1500-225 model at 600 Vac

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c21 (same source; check the conditions); possible conflict with c22 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)

c21 verified · fact nominal 200 KiloW

Conditions: XGI 1500-200 model at 480 Vac

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c20 (same source; check the conditions); possible conflict with c22 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)

c22 verified · fact nominal 175 KiloW

Conditions: XGI 1500-175 model at 480 Vac

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c20 (same source; check the conditions); possible conflict with c21 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)

c23 drafted · lead nominal 125 KiloW

Conditions: XGI 1500-125 model at 600 Vac

review note: possible conflict with c20 (same source; check the conditions); possible conflict with c21 (same source; check the conditions); possible conflict with c22 (same source; check the conditions)

Referenced by