Yaskawa Solectria XGI-1500 CRIT-7

Code
CRIT-7
Shown as
Ground Fault, Excessive Leakage Current
Vendor severity
Critical
Page
53
ID
fc:yaskawa-solectria-xgi-1500-crit7
IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-xgi-1500-crit7
Status
active
Also known as
CRIT-7, crit7, Yaskawa Solectria CRIT-7, Ground Fault, Excessive Leakage Current
Category
Inverters
Class fault drafted · lead
Production not stated
Clears needs service drafted · lead

Decoded

Reports ground fault alarm or trip; look at PV array; do: contact system installer.

What can be behind Ground fault alarm or trip

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
CPS
CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
Enphase
Enphase M215-M250 GFI Tripped
Fronius
Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
Huawei
Huawei SUN2000-100KTL-USH0 2031
SMA
SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
Schneider Electric
Schneider Electric CL125 033
Solis
Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
Sungrow
Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
Yaskawa Solectria
Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7

Same code in other families

Claims

defined_in

c1 drafted · lead xgi-1500 manual rev i 21 sep 2021

c2 drafted · lead XGI 1500-125-166 IOM DOCR-071015-FF

c3 drafted · lead XGI 1500 175-250 IOM DOCR-071074-DD

has_event_class

c4 drafted · lead Fault (device stops or needs intervention)

from the table header

reports

c5 drafted · lead Ground fault alarm or trip

affects

c6 drafted · lead PV array

review note: support check: partial - The PV array disconnect, combiners and panels are mentioned, but the passages do not state that the fault affects the…

mitigated_by

c7 drafted · lead Contact system installer

has_recovery

c8 drafted · lead Service required

Qualified person must locate and repair the ground fault; equipment must not be touched.

applies_to

c9 drafted · lead Solectria XGI 1500

Data