Code
6487
Page
38
ID
fc:sma-sunny-central-cp-xt-6487
IRI
https://solarlattice.org/kb/fc/sma-sunny-central-cp-xt-6487
Status
active
Also known as
6487, SMA 6487
Category
Inverters
Class not stated
Production not stated
Clears needs service drafted · lead

Decoded

Reports ground fault alarm or trip; look at surge protection device; do: contact manufacturer service.

What can be behind Ground fault alarm or trip

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
CPS
CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200
Enphase
Enphase M215-M250 GFI Tripped
Fronius
Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
Huawei
Huawei SUN2000-100KTL-USH0 2031
SMA
SMA SB-US-40 3501, SMA SB-US-40 3601, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601
Schneider Electric
Schneider Electric CL125 033
Solis
Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02
Sungrow
Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
Yaskawa Solectria
Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7

Claims

defined_in

c1 drafted · lead SCCPXT-E7-WA-en-37

reports

c2 drafted · lead Ground fault alarm or trip

Ground fault on the AC side.

affects

c3 drafted · lead Surge protection device

review note: support check: partial - Overvoltage protection is to be checked, but the passage doesn't state the surge protection device is affected.

mitigated_by

c4 drafted · lead Contact manufacturer service

After checking overvoltage protection.

has_recovery

c5 drafted · lead Service required

applies_to

c6 drafted · lead Sunny Central CP XT

Data