Fault codes › SMA › Sunny Boy 3.0-7.7-US (SBx.x-1SP/1TP-US-40)
SMA SB-US-40 3601
- Code
3601
- Shown as
- High discharge curr. > Check generator
- Page
- 50
- ID
fc:sma-sb-us-40-3601
- IRI
https://solarlattice.org/kb/fc/sma-sb-us-40-3601
- Status
- active
- Also known as
- 3601, SMA 3601, High discharge curr. > Check generator
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports high leakage current, ground fault alarm or trip; look at PV array, DC cable; do: grounding conductor check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
- CPS
- CPS SCA25KTL-208 Fault0090, CPS SCA25KTL-208 GFCIErr, CPS SCA25KTL-480 Fault0090, CPS SCA25KTL-480 GFCIErr, CPS SCA50-100K-T PFault0040, CPS SCA50-100K-T Protect0200, CPS SCA50-100K-T Protect0650, CPS SCH100-125KTL Fault0090, CPS SCH100-125KTL GFCIErr, CPS SCH125KTL-AIO Fault0090, CPS SCH125KTL-AIO GFCIErr, CPS SCH200-250K-T Fault0650, CPS SCH200-250K-T GFCIErr, CPS SCH275KTL Fault0090, CPS SCH275KTL GFCIErr, CPS SCH350KTL Fault0090, CPS SCH350KTL GFCIErr
- Canadian Solar
- Canadian Solar 185-255K ILeak-PRO 01/02/03/04, Canadian Solar 23-28KTL-CT GFCIErr
- Enphase
- Enphase M215-M250 GFI Tripped
- Fronius
- Fronius Galvo 475, Fronius Primo 475, Fronius Symo 475
- Huawei
- Huawei SUN2000-100KTL-USH0 2031, Huawei SUN2000-100KTL-USH0 2051, Huawei SUN2000-25-30KTL-US 318, Huawei SUN2000-45KTL-US-HV-D0 318
- KACO new energy
- KACO new energy blueplanet TL3 18, KACO new energy blueplanet TL3 78
- SMA
- SMA SB-US-40 3501, SMA SB-US-40 3701, SMA SB-US-41 3501, SMA SB-US-41 3601, SMA SB-US-41 3701, SMA SBSE-US-50 3501, SMA SBSE-US-50 3601, SMA SBSE-US-50 3701, SMA PEAK3-US 3501, SMA PEAK3-US 3601, SMA PEAK3-US 3701, SMA CORE1-US 3501, SMA CORE1-US 3701, SMA STP-TL-US 3501, SMA STP-TL-US 3601, SMA STP-TL-US 3701, SMA STP-X-US 3501, SMA STP-X-US 3601, SMA STP-X-US 3701, SMA SC-CP-XT 3501, SMA SC-CP-XT 3502, SMA SC-CP-XT 3507, SMA SC-CP-XT 3512, SMA SC-CP-XT 3515, SMA SC-CP-XT 3601, SMA SC-CP-XT 6487
- Schneider Electric
- Schneider Electric CL125 012, Schneider Electric CL125 033, Schneider Electric CL125 056
- Solis
- Solis 3P-5G-US ILeak-PRO 01/02/03/04, Solis RHI-1P-HV ILeak-PRO 01/02/03/04, Solis S6-EH1P ILeak-PRO 01/02/03/04, Solis S6-EH2P ILeak-PRO01, Solis S6-EH2P ILeak-PRO02, Solis S6-EH2P ILeak-PRO03, Solis S6-EH2P ILeak-PRO04, Solis S6-EH2P PV ISO-PRO01, Solis S6-EH2P PV ISO-PRO02, Solis S6-EH3P30-60K ILeak-PRO01, Solis S6-EH3P30-60K ILeak-PRO02, Solis S6-EH3P30-60K ILeak-PRO03, Solis S6-EH3P30-60K ILeak-PRO04, Solis S6-EH3P30-60K PV ISO-PRO01, Solis S6-EH3P30-60K PV ISO-PRO02, Solis S6-EH3P75-150K ILeak-PRO01, Solis S6-EH3P75-150K ILeak-PRO02, Solis S6-EH3P75-150K ILeak-PRO03, Solis S6-EH3P75-150K ILeak-PRO04, Solis S6-EH3P75-150K PV ISO-PRO01, Solis S6-EH3P75-150K PV ISO-PRO02, Solis S6-GC ILeak-PRO, Solis S6-GU ILeak-PRO
- Sungrow
- Sungrow SG-CX-US 012, Sungrow SG200HX 012, Sungrow SG200HX 1600-1615, Sungrow SG200HX 1632-1655, Sungrow SG250HX 12, Sungrow SG250HX 1600-1615, Sungrow SG250HX 1632-1655, Sungrow SG350HX 012, Sungrow SG350HX 1600-1615, Sungrow SG350HX 1632-1655
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL GFCI.Err, Yaskawa Solectria PVI-25TL-R Fault0090, Yaskawa Solectria PVI-25TL-R GFCI.Err, Yaskawa Solectria PVI-TL GFCI.Err, Yaskawa Solectria SGI-XTM DC GND Fault, Yaskawa Solectria SGI-XTM RCM Fault, Yaskawa Solectria SGI-XTM RCM Warn, Yaskawa Solectria XGI-1500-1MW CRIT-7, Yaskawa Solectria XGI-1500 CRIT-7, Yaskawa Solectria XGI-1500-DCG CRIT-7
Same code in other families
Claims
defined_in
c1 drafted · lead
SBxx-US-1XP-40-BA-en-13
reports
c2 drafted · lead
High leakage current
c3 drafted · lead
Ground fault alarm or trip
affects
c4 drafted · lead
PV array
c5 drafted · lead
DC cable
mitigated_by
c6 drafted · lead
Grounding conductor check
has_event_class
c7 drafted · lead
Fault (device stops or needs intervention)
has_production_effect
c8 drafted · lead
Trip (production stops)
has_recovery
c9 drafted · lead
Auto-reset with a retry limit
Reconnects automatically; after five occurrences in a day feed-in is terminated.
applies_to
c10 drafted · lead
Sunny Boy 3.0-7.7-US-40 proposed
Data