Solar Lattice

Fault codes › CPS › CPS SCH350KTL-DO/US-800

CPS SCH350KTL GFCIErr

Code
GFCIErr
Shown as
high leakage current
Page
96
ID
fc:chint-sch-350ktl-gfcierr
IRI
https://solarlattice.org/kb/fc/chint-sch-350ktl-gfcierr
Status
active
Also known as
GFCIErr, gfcierr, CPS GFCIErr, high leakage current
Category
Inverters
Class not stated
Production stops drafted · lead
Clears not stated

Decoded

Reports high leakage current; look at PV array, DC cable; confirm with fault localization; do: DC wiring check.

What can be behind High leakage current

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
CPS
CPS SCA25KTL-208 Fault0090, CPS SCA25KTL-208 GFCIErr, CPS SCA25KTL-480 Fault0090, CPS SCA25KTL-480 GFCIErr, CPS SCA50-100K-T Protect0650, CPS SCH100-125KTL Fault0090, CPS SCH100-125KTL GFCIErr, CPS SCH125KTL-AIO Fault0090, CPS SCH125KTL-AIO GFCIErr, CPS SCH200-250K-T Fault0650, CPS SCH200-250K-T GFCIErr, CPS SCH275KTL Fault0090, CPS SCH275KTL GFCIErr, CPS SCH350KTL Fault0090
Canadian Solar
Canadian Solar 185-255K ILeak-PRO 01/02/03/04, Canadian Solar 23-28KTL-CT GFCIErr
Huawei
Huawei SUN2000-100KTL-USH0 2051, Huawei SUN2000-25-30KTL-US 318, Huawei SUN2000-45KTL-US-HV-D0 318
KACO new energy
KACO new energy blueplanet TL3 18, KACO new energy blueplanet TL3 78
SMA
SMA SB-US-40 3601, SMA SB-US-41 3601, SMA SBSE-US-50 3601, SMA PEAK3-US 3601, SMA STP-TL-US 3601, SMA STP-X-US 3601, SMA SC-CP-XT 3601
Schneider Electric
Schneider Electric CL125 012, Schneider Electric CL125 056
Solis
Solis 3P-5G-US ILeak-PRO 01/02/03/04, Solis RHI-1P-HV ILeak-PRO 01/02/03/04, Solis S6-EH1P ILeak-PRO 01/02/03/04, Solis S6-EH2P ILeak-PRO01, Solis S6-EH2P ILeak-PRO02, Solis S6-EH2P ILeak-PRO03, Solis S6-EH2P ILeak-PRO04, Solis S6-EH3P30-60K ILeak-PRO01, Solis S6-EH3P30-60K ILeak-PRO02, Solis S6-EH3P30-60K ILeak-PRO03, Solis S6-EH3P30-60K ILeak-PRO04, Solis S6-EH3P75-150K ILeak-PRO01, Solis S6-EH3P75-150K ILeak-PRO02, Solis S6-EH3P75-150K ILeak-PRO03, Solis S6-EH3P75-150K ILeak-PRO04, Solis S6-GC ILeak-PRO, Solis S6-GU ILeak-PRO
Sungrow
Sungrow SG-CX-US 012, Sungrow SG200HX 012, Sungrow SG250HX 12, Sungrow SG350HX 012
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL GFCI.Err, Yaskawa Solectria PVI-25TL-R Fault0090, Yaskawa Solectria PVI-25TL-R GFCI.Err, Yaskawa Solectria PVI-TL GFCI.Err, Yaskawa Solectria SGI-XTM RCM Warn

Same code in other families

Claims

defined_in

c1 drafted · lead CPS SCH350KTL-DO-US-800 User Manual Rev 2.2

reports

c2 drafted · lead High leakage current

affects

c3 drafted · lead PV array

c4 drafted · lead DC cable

review note: support check: partial - Passages say to trace wirings of the faulted string for leakage, but never name DC cable specifically.

detected_by

c5 drafted · lead Fault localization

mitigated_by

c6 drafted · lead DC wiring check

has_production_effect

c7 drafted · lead Trip (production stops)

review note: support check: partial - The passages give no statement that production stops or the inverter trips for GFCIErr; only a protection type and troubleshooting…

applies_to

c8 drafted · lead CPS SCH350KTL-DO/US-800

Data