Fault codes › Yaskawa Solectria › Solectria PVI 20/25TL-480-R
Yaskawa Solectria PVI-25TL-R Fault0090
- Code
Fault0090
- Shown as
- Static leakage current high
- Vendor severity
- Fault
- Page
- 83
- ID
fc:yaskawa-solectria-pvi-20-25tl-480-r-fault90
- IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-20-25tl-480-r-fault90
- Status
- active
- Also known as
- Fault0090, fault90, Yaskawa Solectria Fault0090, Static leakage current high
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Clears
not stated
Decoded
Reports high leakage current; look at PV array, DC cable; confirm with fault localization; do: DC wiring check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E018, ABB / FIMER PVS-60-TL E018, ABB / FIMER TRIO-20.0-27.6-TL E018, ABB / FIMER UNO-DM-3.3-5.0-PLUS E018, ABB / FIMER UNO-DM-6.0-PLUS E018
- CPS
- CPS SCA25KTL-208 Fault0090, CPS SCA25KTL-208 GFCIErr, CPS SCA25KTL-480 Fault0090, CPS SCA25KTL-480 GFCIErr, CPS SCA50-100K-T Protect0650, CPS SCH100-125KTL Fault0090, CPS SCH100-125KTL GFCIErr, CPS SCH125KTL-AIO Fault0090, CPS SCH125KTL-AIO GFCIErr, CPS SCH200-250K-T Fault0650, CPS SCH200-250K-T GFCIErr, CPS SCH275KTL Fault0090, CPS SCH275KTL GFCIErr, CPS SCH350KTL Fault0090, CPS SCH350KTL GFCIErr
- Canadian Solar
- Canadian Solar 185-255K ILeak-PRO 01/02/03/04, Canadian Solar 23-28KTL-CT GFCIErr
- Huawei
- Huawei SUN2000-100KTL-USH0 2051, Huawei SUN2000-25-30KTL-US 318, Huawei SUN2000-45KTL-US-HV-D0 318
- KACO new energy
- KACO new energy blueplanet TL3 18, KACO new energy blueplanet TL3 78
- SMA
- SMA SB-US-40 3601, SMA SB-US-41 3601, SMA SBSE-US-50 3601, SMA PEAK3-US 3601, SMA STP-TL-US 3601, SMA STP-X-US 3601, SMA SC-CP-XT 3601
- Schneider Electric
- Schneider Electric CL125 012, Schneider Electric CL125 056
- Solis
- Solis 3P-5G-US ILeak-PRO 01/02/03/04, Solis RHI-1P-HV ILeak-PRO 01/02/03/04, Solis S6-EH1P ILeak-PRO 01/02/03/04, Solis S6-EH2P ILeak-PRO01, Solis S6-EH2P ILeak-PRO02, Solis S6-EH2P ILeak-PRO03, Solis S6-EH2P ILeak-PRO04, Solis S6-EH3P30-60K ILeak-PRO01, Solis S6-EH3P30-60K ILeak-PRO02, Solis S6-EH3P30-60K ILeak-PRO03, Solis S6-EH3P30-60K ILeak-PRO04, Solis S6-EH3P75-150K ILeak-PRO01, Solis S6-EH3P75-150K ILeak-PRO02, Solis S6-EH3P75-150K ILeak-PRO03, Solis S6-EH3P75-150K ILeak-PRO04, Solis S6-GC ILeak-PRO, Solis S6-GU ILeak-PRO
- Sungrow
- Sungrow SG-CX-US 012, Sungrow SG200HX 012, Sungrow SG250HX 12, Sungrow SG350HX 012
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL GFCI.Err, Yaskawa Solectria PVI-25TL-R GFCI.Err, Yaskawa Solectria PVI-TL GFCI.Err, Yaskawa Solectria SGI-XTM RCM Warn
Claims
defined_in
c1 drafted · lead
PVI 20-25TL-480-R IOM DOCR-071030-A
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the code prefix
reports
c3 drafted · lead
High leakage current
affects
c4 drafted · lead
PV array
c5 drafted · lead
DC cable
review note: support check: partial - Tracing wiring of faulted string for leakage is stated, but DC cable is not explicitly named.
detected_by
c6 drafted · lead
Fault localization
Reconnect strings one at a time to find the one triggering the alarm.
mitigated_by
c7 drafted · lead
DC wiring check
Trace faulted string wiring for leakage to earth.
applies_to
c8 drafted · lead
Solectria PVI 20/25TL-480-R
Data